i o*
.pys ntag fi UNITED STATES i
A E i(Aef;'( i 0 NUCLEAR REGULATORY COMMISSION g %, 4 c!
WASHINGTON. D.C. 20556-0001
,,, m [j ENTERGY OPERATIONS. INC.
DOCKET NO. 50-382 WATERFORD STEAM ELECTRIC STATION. UNIT 3 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 83 License No. NPF-38 1.
The Nuclear Regulatory Commission (the Commission) has found that:
A.
The application for amendment by Entergy Operations, Inc. (the licensee) dated October 21, 1992, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act),
and the Commission's rules and regulations set forth in 10 CFR Chapter I, s
B.
The facility will operate in conformity with the application, the-t provisions of the Act, and the rules and regulations of the Commission; i
C.
There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.
The issuance of this amendment will not be inimical to the common
~i defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.
e i
I I
e i
l
. 4 2.
Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C(2) of Facility Operating License No. NPF-38 is hereby amended to read as follows:
(2) Technical Specifications and Environmental Protection Plan The Technical Specifications contained in Appendix A, as revised through Amendment No. 83, and the Environmental Protection Plan contained in Appendix B, are hereby incorporated in the license.
The licensee shall operate the facility in accordance with the-Technical Specifications and the Environmental Protection Plan.
3.
This license amendment is effective as of its date of issuance.
FOR THE NUCLEAR REGULATORY COMMISSION Harry Ro d, Acting Director Project Directorate IV-I Division of Reactor Projects III/IV/V Office of Nuclear Reactor Regulation
Attachment:
Changes to the Technical Specifications Date of Issuance: July 26, 1993
- jdI.*
=
It
' ATTACHMENT TO LICENSE hMENDMENT-NO. R1 1
TO FACILITY OPERATING LICENSE'NO. NPF-38.
DOCKET'NO. 50-382
-I Replace the.following page of the Appendix A Technical Specifications with the attached page. The revised page is identified by Amendment number and-contains a vertical line indicating the areas of change. The. corresponding.
i overleaf page are also provided to maintain document completeness.
REMOVE PAGE INSERT PAGE I
6-6
.6-6 1
[
k a
i h
k r
l
-i 1
l.I I
l l
.i
-f.
>l i'i
)
ADMINISTRATIVE CONTROLS k
6.2.3 INDEPENDENT TECHNICAL REVIEWS FUNCTION 6.2.3.1 Independent technical reviews shall be conducted to examine plant operating characteristics, NRC issuances, industry advisories, Licensee Event Reports and other sources of plant design and operating experience information which may indicate areas for improving plant safety.
COMPOSITION 6.2.3.2 A minimum of five, full-time engineers shall be dedicated to perform the independent technical review functions described herein.
Each shall have a Bachelor's Degree in Engineering or Physical Science or equivalent and at least two years professional level experience in his/her field.
RESPONSIBILITIES 6.2.3.3 Independent technical review responsibilities shall encompass surveillance to independently verify
- that these activities are performed safely and correctly and that human errors are reduced as much as practical.
AUTHORITY 6.2.3.4 Individuals assigned to authority to perform the functions and responsibilities delineated above shall make detailed recommendations for revised procedures, equipment modifications, maintenance activities, operations activities, or other means of improving unit safety.
RECORDS 6.2.3.5 Written records of the activities described above shall be maintained.
Recommendations for improving unit safety shall be forwarded each calendar month to the Director of Nuclear Safety.
6.2.4 SHIFT TECHNICAL ADVISOR 6.2.4.1 The Shift Technical Advisor shall provide advisory technical support to the Shift Supervisor in the areas of thermal hydraulics, reactor engineer-ing, and plant analysis with regard to the safe operation of the unit. The STA shall meet the requirements of either Option 1 or 2 as shown below:
a.
Option 1 - Combined SRO/STA Position. This option is satisfied by assigning an individual with the following qualifications to each operating shift crew as one of the SRO's required by 10 CFR 50.54(m) (2) (1):
- Not responsible for sign-off function.
WATERFORD - UNIT 3 6-6 AMENDNENT NO. 18,53,33
TABLE 6.2-1 MINIMUM SHIFT CREW COMPOSITION POSITION NUMBER OF INDIVIDUALS REQUIRED TO FILL POSITION MODE 1, 2, 3, OR 4 MODE 5 OR 6 SS 1*
1 SRO 1*
None R0 2
1 A0 2
1 STA 1*
None l.
SS Shift Supervisor with a Senior Operator License SRO Individual with a Senior Operator License RO Individual with an Operator License AD Auxiliary Operator STA Shift Technical Advisor Except for the Shift Supervisor, the shift crew composition may be one less than the minimum requirements of Table 6.2-1 for a period of time not to exceed 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> in order to accommodate unexpected absence of on-duty shift crew members provided immediate action is taken to restore the shift crew composi-tion to within the minimum requirements of Table 6.2-1.
This provision does not permit any shift crew position to be unmanned upon shift change due to an oncoming shift crewman being late or absent.
During any absence of the Shift Supervisor from the control room while the unit is in MODE 1, 2, 3 or 4, an individual (other than the Shift Technical Advisor) with a valid Senior Operator license shall be designated to assume the control room command function. During any absence of the Shift Supervisor from the control room while the unit is in MODE 5 or 6, an individual with a valid Senior Operator or Operator license shall be designated to assume the control room command function.
i
- An individual with SRO/STA qualifications can satisfy the SS/STA or SRO/STA position requirements simultaneously.
t WATERFORD - UNIT 3 6-S AMENDMENT NO. 7
- - -