Subject:
Waterford 3 SES Docket No. 50-382 License No. NPF-38 Monthly Operating Report Gentlemen:
Attached is the subject monthly report which covers the operating statistics for the month of July,1993. This report is submitted per Section 6.9.I.6 of the Waterford 3 Technical-Specifications for Facility Operating License No. NPF-38.
Very truly yours, t
R.F. Burski l
Director Nuclear Safety RFB/TSB/ssf Attachment-cc:
J.L. Milhoan, (NRC Region IV), D.L. Wigginton (NRC-NRR),
R.B. McGehee, N.S. Reynolds, F. Yost (Utility Data-Institute, Inc.), J.T. Wheelock (INP0 Records Center),
NRC Resident Inspectors Office
/1 lf I
9308170274 930731
~ II PDR. ADDCK 050003G2 E
R, PDR
i 1y n
-)
I NRC MONTHLY OPERATING REPORT
SUMMARY
OF OPERATIONS
^1 WATERFORD 3 i
JULY 1993 The unit operated at an average reactor power of 99.65% and experienced. no shutdowns or significant power reductions during the period.
-i r
q i
I t
1 4
I i
.J I
.:2 -
a'.
1 t
i 1
..i PRESSURIZER SAFETY VALVE FAILURES AND CHALLENGES WATERFORD 3 q
t During the month of July 1993, there were no pressurizer safety valve failures or challenges.
4 h
ij i
)
l l
.l i
-i 1
I
-~
r, OPERATING DATA REPORT c.
DOCKET NUMBER: 50-382 UNIT NAME: WATERFORD 3 DATE OF REPORT: AUGUST,1993 COMPLETED BY:
E. G. WlEGERT TELEPHONE: 504-739-6446 OPERATING STATUS 1.
Reporting Period: July,1993 Gross Hours in Reporting Period: 744
.2.
Currently Authorized Power Level (MWt): 3390 Maximum Dependable Capacity (Net MWe): 1075 Design Electrical Rating (Net MWe): 1104 3.
Power Level to which Restricted (if any) (Net MWe): N/A
.t 4.
Reasons for Restriction (if any): N/A THIS MONTH YR TO DATE CUMULATIVE 5.
Number of Hours Reactor was Critical 744.0 5,034.0 57,427.0 6.
Reactor Reserve Shutdown Hours 7.
Hours Generator was On-line 744,0 5,019.0 56,615.2' 8.
Unit Reserve Shutdown Hours -02 9.
Gross Thermal Energy Generated (MWH) 2,513,308 16,936,141 186,603,194 j
- 10. Gross Electrical Energy Generated (MWH) 813.490 5,532,860 62,394,330
- 11. Net Electrical Energy Generated (MWH) 775.798 5,289,091 59,460,708-
-l
- 12. Reactor Service Factor
-100.0 99.0 83.4 i
- 13. Reactor Availability Factor 100.0 99.0 83.4 14; : Unit Service Factor 100.0' 98.'7 82.3
- 15. Unit Availability Fector 100.0 98.7 82.3
- 16. Unit Capacity Factor jusing MDC) 97.0-96 7 80.4 G ~
1 OPERATING DATA REPORT DOCKET NUMBER: 50-382 UNIT NAME: WATERFORD 3 DATE OF REPORT: AUGUST,1993
=
COMPLETED BY:
E. G. WlEGERT TELEPHONE: 504-739-6446 QPERATING DATA REPORT (Con't)
- 17. Unit Capacity Factor (Using DER) 94.5 94.2 78.2
- 18. Unit Forced Outage Rate 1.3
' 3.7 19.
Shutdowns Scheduled over next 6 Months (type, date and duration of each):
N/A 20.
If Shutdown at end of report period, estimated date of startup: N/A 21.
Unit in Commercial Operation THIS MONTH YR TO DATE CUMULATIVE
- 22. Hours in Reporting Period 744.0 5,087.0 68,832.0 I
- 23. - Unit Forced Outage Hours 0.0 68.0 2,178.7
?
'b 24.
Nameplate Rating (Gross MWe): 1200 25.
If Changes Occur in Capacity Ratings (ltems Number 2 and 24) Since Last Report, Give Reasons: N/A 1
l l
?
r 1
i AVERAGE DAILY UNIT POWER LEVEL i
DOCKET NUMBER: 50-382 UNIT NAME: WATERFORD 3
-l DATE OF REPORT: AUGUST,1993 COMPLETED BY:
E. G. WlEGERT l
TELEPHONE: 504-739-6446
{
l MONTH JULY DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)
. MWe-Net)
(
1 1051 17 1047 2
1043 18 1048 i
3 1036 19 1047 4
1029 20 1046 5
1036 21 1046 6
1045 22 1003 7
1050 23 1026 j
r 8
1049 24 1043 9
1048 25 1043 10 1048 26 1045 i
11 1048 27 1044 12 1049 28 1035 13 1048 29 1041 14 1049 30 1043 15 1045 31 1044 16 1049 INSTRUCTIONS I
On this format, list the average daily unit power level in MWe-Net for each day in the reporting month. Compute to the nearest whole megawatt.
1 I
^b u
, :p
. UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NUMBER: 50-382 UNIT NAME:' WATERFORD 3 DATE OF REPORT: AUGUST,1993 COMPLETED BY:
E. G. WlEGERT TELEPHONE: 504-739-6446 REPORT FOR JULY.1993 Type Method of Shutting F = Forced Duration Down the Reactor or Cause, Comments and Number D. ale S....= Scheduled (Hours)
Reason (1)
Reducino Power (2)
Corrective Actions
~
NONE (1) REASON (2) METHOD Equipment Failure (explain) 1 Manual A
=
=
Maintenance or Test.
2 Manual Scram B
=
=
C=
Refueling 3=
Automatic Scram Continuation from Previous Period D=
Regulatory Restriction 4
=
~E=
' Operator Training and 5
Power Reduction
=
License Examination 6=
Other (explain)-
F=
Administrative Operational Error (explain)
G
=
Other (explain)
-H
=
1
_,..w.--
+.. -,
. $.w.-, -,,
.-,s
..m-.
mm s.m-..m %.
..m
.m' m..