.i

/*L

s

~.bb

3

p

' Docket Nos. 50-334

MS06 Ug

50-412

Mr. J. D. Sieber

Senior Vice President

Nuclear Power Division

'

Duquesne Light Company

Post Office Box 4

- '

Shippingpon, Pennsylvania 15077

-

Dear Mr. Sieber:

SUBJECT: NRC Combined Inspection Nos. 50-334/93-15; 50-412/93-16

l

l

An announced safety inspection of the radioactive waste management and transponation

activities at your facility was conducted by Mr. J. Nick on July 26-30,1993. The results of

this inspection were discussed with you and your staff on July 30,1993.

Areas reviewed during this inspection were imponant to health and safety and am discussed

in the enclosed inspection mpod. Tid findings are based upon inspector observation,

interviews of personnel, and review of records. Areas reviewed included storage of

f

radioactive waste, mdioactive waste processing, transponation of radioactive materials,

staffing levels, staff qualifications, training, quality assurance, and relevant procedures.

Your radioactive waste management and transponation program was generally effective in

,

safely disposing of radioactive materials. Areas toured in your facility were well maintained

t

and exhibited good housekeeping. The radioactive waste processing was performed by

,

qualified individuals with documented training and qualifications. The assurance of quality,

including audits and surveillances, was comprehensive and detailed. Improvements were

!

noted in the training for radiological controls technicians preparing and documenting

radioactive waste shipments. Minor weakness was noted in the calculation for curie content

of waste containers based upon dose rate measurements and isotopic content.

Within the scope of this inspection, one non-cited violation was identified regarding the

!

improper completion of shipping papers and is described in the attached inspection repon.

This violation was not cited due to its minor safety significance and because of your staff's

thorough efforts in instituting cormctive actions.

,

I

9308170018 930806

PDR

ADOCK-05000334

OFFICIALRECORDCOPY

'

g p.

p p.

g jh

1 f qn

j

G

PDR

a

a La

UV

.

,

u.

--

,

c.:

s.

$ 0 6 1993,

[

Duquesne Light Company -

2

No response to this letter is required. Your cooperation with us in this matter is appreciated.

Sincerely,

MM%

JamesNy

f'

r

Facilities Radiological Safety .

and Safeguards Branch

Division of Radiation Safety

and Safeguards

Enclosure:

Inspection Report Nos. 50-334/93-15 and 50-412/93-16

cc w/ encl:

' G. S. Thomas, Vice President, Nuclear Services

D. E. Spoerry, Vice President, Nuclear Operations

L. R. Freeland, General Manager, Nuclear Operations Unit

K. D. Grada,- Manager, Quality Services Unit

N. R. Tonet, Manager, Nuclear Safety Department

H. R. Caldwell, General Superintendent, Nuclear Operations

K. Abraham, PAO (2)

- Public Document Room (PDR)

I.ocal Public Document Room (LPDR)

Nuclear Safety Information Center (NSIC)

NRC Resident Inspector

E

Commonwealth of Pennsylvania

State of Ohio

.

OFFICIAL RECORD COP.Y

L.

...

4

MI6 13

Duquesne Light Company

3

,

bec w/ encl:

Region I Docket Room (with concurrences)

W. Pasciak, DRSS

-

I

bec w/ encl (VIA E-MAIL):

W. Butler, NRR

G. Edison, NRR

V. McCree, OEDO

i

.

,

i

.

,

.(

RI:DRSS

li

DRSS

'

J. Nick

e. Pasetak

J. Joyner

V

i

i

08/f/93

08/(g/93

08/(p/93

l

1

<

>

'

OFF! 1AL RECORD COPY