O O
June 1, 1993 Mr. Richard G. Ballintine l
Vice President Government Relations and Administration Rosemount Aerospace, Inc.
14300 Judicial Road Burnsville, Minnesota 55337
Dear Mr. Ballintine:
i The NRC staff is reexamining whether we should specify additional actions beyond those provided in NRC Bulletins 90-01 and 90-01, Supplement 3, regarding the Rosemcunt transmitter " loss of fill-oil" issue. An NRC review group, which I am leading, has been formed to aid in making this determination.
I envision the review group will want to interface with the cognizant Rosemount staff about the third or fourth week in June.
I will be contacting you shortly by telephone to make the necessary arrangements.
Enclosed for your information is a copy of the Review Group Charter.
We appreciate your cooperation.
Roy P. Zimmerman, Deputy Director Division of Reactor Inspection and Licensee Performance Office of Nuclear Reactor Regulation
Enclosure:
As stated cc:
Kenneth E. Ewald Business Unit Manager, Nuclear Rosemount Aerospace, Inc.
)
1256 Trapp Road Eagan, Minnesota 55121 Jay E. Silberg, Partner
\\
Shaw, Pittman, Potts &
Trowbridge 2300 N Street, N.W.
Washington, D.C.
20037 bec:
J. Sniezek, ED0 J. Partlow, NRR H. Scott, IG 77d08 '// /[ccenv,;wQSc Distribution: ~/oed" ~
I Central Files /PDR XRf ji'-//-k(08 l DD:DRIL {f~b*
g). /, ( n.uj )
giygrman:1d q
NO oA00$ ES0$$n hddIAI1/9b
,r.dC RE CENTEi! CO,M i o
.