8

4

eg

9i rm

~

Docket Nos. 50-327, 50-328

License Nos. DPR-77, DPR-79

Tennessee Valley Authority

ATTN: Dr. Mark 0. Medford

!

Vice President, Technical

j

Support

3B Lookout Place

_ '

1101 Market Street

Chattanooga, TN 37402-2801

Gentlemen:

,

,

SUBJECT:

NRC INSPECTION REPORT N0. 50-327/93-26 AND 50-328/93-26

This refers to the inspection conducted by G. MacDonald of this office on

June 14-23, 1993. The inspection included a review of activities authorized

'

for your Sequoyah facility. At the conclusion of the inspection, the findings

were discussed with those members of your staff identified in the report.

Areas examined during the inspection are identified in the report. Within

these areas, the inspection consisted of selective examinations of procedures

and representative records, interviews with personnel, and observation of

i

activities in progress.

Within the scope of the inspection, violations or deviations were not identi-

fled.

j

An event occurred on June 14, 1993, where an incorrectly installed current

transformer in circuit breaker 1614 tripped during a reactor coolant pump

motor start causing an unplanned challenge to the emergency diesel generators.

We are concerned about this problem because it demonstrated a breakdown in

your control of maintenance in the areas of configuration management and post

maintenance testing.

This event was very similar to an incident which occurred on December 19,

1991. During the December 19, 1991, incident an incorrectly installed current

transformer led to a trip of the main generator.

This indicates that your

corrective actions for the December 19, 1991, incident were inadequate to

prevent recurrence. We request that you respond to this item and provide your

proposed corrective action.

In accordance with 10 CFR 2.790 of the NRC's " Rules of Practice," a copy of

this letter and its enclosure will be placed in the NRC Public Document Room.

The responses directed by this letter are not subject to the clearance

procedures of the Office of Management and Budget as required by the Paperwork

!

Reduction Act of 1980, Pub. L. No.96-511.

9308050017 930721

1

PDR

ADOCK 05000327

G

PDR

l

,

ZEo/

.

.

-

. -

_

-

-

-.

-

.

.-

..

Tennessee Valley Authority

2

JUL 21 toc 3

Should you have any questions concerning this letter, please contact us.

Sincerely,

.

I

IS.

i

Caudie A. Julian,- Chief

l

Engineering Branch

l

Division of Reactor Safety

1

Enclosure:

j

NRC Inspection Report

cc w/ encl:

W. H. Kennoy, Director

Tennessee Valley Authority

ET 12A

400 West Summit Hill Drive

Knoxville, TN 37902

R. M. Eytchison, Vice President

'

Nuclear Operations

Tennessee Valley Authority

3B Lookout Place

1101 Market Street

Chattanooga, TN 37402-2801

B. S. Schofield, Manager

Nuclear Licensing and

Regulatory Affairs

Tennessee Valley Authority

5B Lookout Place .

1101 Market Street

Chattanooga, TN 37402-2801

Robert.Fenech, Vice President

Sequoyah Nuclear Plant

Tennessee Valley Authority

P.'O. Box 2000

Soddy-Daisy, TN 37379

l

TVA Representative

Tennessee Valley Authority

Rockville Office

11921 Rockville Pike

Suite 402

Rockville, MD 20852

(cc w/enci cont'd - See page 3)

i

.

-.

-

-

_

. l

r

..

.

-

.

,

Tennessee Valley Authority

3

WL 2 l 1993

)

(cc w/ encl cont'd)

Ralph H. Shell

Site Licensing Manager

Sequoyah Nuclear Plant

,

i

P. O. Box 2000

Soddy-Daisy, TN 37379

Michael H. Mobley, Director

-

Division of Radiological Health

3rd Floor, L and C Annex

'

401 Church Street

Nashville, TN 37243-1532

General Counsel

Tennessee Valley Authority

-

ET IIH

400 West Summit Hill Drive

Knoxville, TN 37902

County Judge

Hamilton County Courthouse

Chattanooga, TN 37402

!

'

bcc w/ encl:

E. W. Herschoff, RII

J. R. Johnson, RII

P. J. Kellogg, RII

'

S. E. Sparks, RII

B. M. Bordenick, OGC

D. E. LaBarge, NRR

-

G. Lainas, NRR

F. Hebdon, NRR

.

Document Control Desk

NRC Resident Inspector

U.S. Nuclear Regulatory Commission

2600 Igou Ferry

Soddy-Daisy, TN 37379

,

,

FILE NAME:

S:/DRS/EB/SQN9326L.GM

[

!

CA

7

h7- S

RIIIflP

RII:DE

t/

GMacDon

7

JM ymlock

PXe' ogg

07

93

91/93

07/ g /93

'

?

t

i

P