GNi=

Global Nuclear Fuel M200029 February 25, 2020 Attn: Document Control Desk Director, Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001

Subject:

GNF-A Semi-Annual Effluent Monitoring Report

References:

1) NRG License SNM-1097, Docket 70-1113
2) NRG Regulation 1 0CFR70.59

Dear Sir or Madam:

Global Nuclear Fuel Scott P. Murray Manager, Facility Licensing 3901 Castle Hayne Road P.O. Box 780 Wilmington, NC 28402 USA T (910) 819-5950 scott.murray@ge.com With respect to activities authorized by NRG License SNM-1097, the Global Nuclear Fuel-Americas, L.L.C. (GNF-A) facility in Wilmington, North Carolina hereby submits the semi-annual effluent monitoring report required by 1 0CFR70.59 for the time period of July through December 2019.

If you have any questions regarding this report, please contact me at (910) 819-5950.

Sincerely, g~m.:~

Facility Licensing agerC/

Attachment:

1) Semi-Annual Effluent Monitoring Report (July-December 2019) cc: NRG Region II Administrator, Atlanta, GA M.Bartlett, USNRC, NMSS L. Pitts, USNRC, RII L. Cox, NCDHHS M. Poirier, ANI SPM 20-008

SEMI-ANNUAL EFFLUENT REPORT Global Nuclear Fuel -Americas. LLC Wilming1on, North Carolina NAC License SNM 1097, Docket # 70-1113 I.

GASEOUS EFFLUENT.PARTICULATE NUCUOES QUANTITY CONCENTRATION (Cl)

(uCl/cc)

U234 7.BtE-06 4.28E-15 U235 3.45E-07 1.89E-16 U236 2.SBE-09 1.41E-18 U238 1.21E-06 6.64E*16 TOTAL 9.37E-06 1 APPENDlXB LIMIT (uCl/cc) 5 E-12 6 E-12 6 E-12 6 E-12 EXHAUST VOLUME =

1.B2E+15 (cc) 2 Nuclide QUANTITY CONCENTRATION 1 APPENDIX S (Cl)

(1,1Cl/cc)

Umlt (1,1Cl/cc)

H*3 6.58E*04 8.10E*12 tE-05 EXHAUST VOLUME =

8.13E+13 (cc)

II.

LIQUID EFFLUENT NUCLIOES QUANTITY CONCENTRATION 1 APPENDIX B LIMIT (Cl)

(uCl/ccl (uCl/cc}

U234 9.22E-03 4.47E-08 3 E-07 U235 4.07E-04 1.97E-09 3 E-07 U236 3.0SE-06 1.4BE*11 3 E-07 U238 l.43E-03 6.92E*09 3 E*07 TOTALU 1.11E-02

%of LIMIT 0.09%

0.00%

0.00%

0.01%

%of LIMIT 0.00%

%of LIMIT 14.89%

0.66%

0.00%

2.31%

TOTAL VOLUME OF LIQUID EFFLUENT=

2 06E+08 (liters)

Ill. ABNORMAL RELEASES Air Waler Total fl Releases 0

0 0

Activity 0

0 0

Released (Cl)

IV.

SUMMARY

' Max Release CEDE. total COE (Lungt. total (uClfcc)

(nuem)

(mrem)

Value 4.47E-08 2.5DE-02 2.10E-01 Limit 3.00E-07 25 25

%of Limit 14.89%

0.10%

0.84%

CEDE mrem 2.14E*02 7.94E-04 5.94E*06 2.79E-03 2.S0E-02 CEDE (mrem) 2.02E-05 CEDE (mrem}

3 26E-06 2.0SE-07 1.02E-09 4.57E-07 3.92E-OI July 2019

  • December 2019 Fiscal Weeks 27-52 COE (Lung) mram 1.B0E-01 6.62E-03 4.95E-05 2.32E*02 2.10E-01 COE (Lung)

COE (Bone Surface)

(mrem)

(mrem) 2.0GE-06 4.73E-05 1.30E-07 2.97E*06 6.49E-10 1.48E-08 2.91E-07 6.62E*06 2.48E-06 5.69E-OS 1 Limit from 10 CFR 20 Appendix B, Table 2, Columns 1 and 2. Air limit adjusted to renect NRC License SNM-1097, Section 1.3.9.

i 2 This nuclide Is included due to the Installation and testing of a neutron generator licensed by the State of North Carolina.

j 3 From nuclide with release that Is the largest percentage of its release limit.

Notes:

Air sampring is continuous. H-3 gaseous effluent is calculated. Water samples analyzed are representative, continuous composite samples of the process effluent stream.

Reported effluent concentration values are representative of the effluent concentration at the point of release and do not consider effects of dilution from point of release to the plant site boundary.