Provides Response to NRC Bulletin 90-001, Loss of Fill Oil in Transmitters Mfg by Rosemount. Pressure & Differential Pressure Transmitters 1153 & 1154 Do Not Perform Any safety-related Function in Current Plant Mode
ML20056A204
Person / Time
Site: Rancho Seco
Issue date: 07/30/1990
From: Keuter D
SACRAMENTO MUNICIPAL UTILITY DISTRICT
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
REF-PT21-90 AGM-NUC-90-210, IEB-90-001, IEB-90-1, NUDOCS 9008060133
Download: ML20056A204 (1)


Text

.- - _.

Osuun v SACAAMENTo MUNICIPAL UTIUTY DISTRICT D 6201 S Street, P.o. Box 16830. Sectamento CA 96B621830. (916) 462 3211 AN ELECTRIC SYSTEM SERVING THE HEART OF CAllFORNIA AGM/NUC 90-210 l

July 30, 1990 i

U. S. Nuclear Regulatory Commission Attn: Document Control Desk Hashington, DC 20555 i

Docket No. 50-312 Rancho Seco Nuclear Generating Station License No. DPR-54 NRC BULLETIN NO. 90-01: LOSS OF FILL-0!L IN TRANSMITTERS MANUFACTURED BY ROSEMOUNT Attention:

John Larkins The purpose of this letter is to respond to the subject Bulletin.

Rancho Seco personnel have reviewed plant records to provide the information required by Actions Requested Items 1 through 5.

This review revealed that pressure and differential pressure transmitters, Models 1153 and 1154, supplied by Rosemount do not perform any safety related function in the current plant mode.

Therefore, the items to be addressed in NRC Bulletin No. 90-01 have been deferred in accordance with the District's administrative controls.

Based on the absence of fuel in the reactor, the Actions Requested in the Bulletin are not applicable.

Members of your staff with questions requiring additional information or clarification may contact Mr. Jerry Delezenski at (209) 333-2935, extension 4914.

Sincerely.

0fM f mlRbt A

/

Dan R. Keuter Assistant General Manager Nuclear cc:

J. B. Martin, NRC, Halnut Creek C. Myers, NRC, Rancho Seco S. Reynolds Hashington DC 9008060133 900730 O

PDR ADOCK 05000312 7

i Q