, e i.c.,,.

.\\

l

. R 2 71990'

.y

~ MEMORANDUM FOR:

Jack E.'Rosenthal,. Chief Reactor. Operations Analysis Branch Division of Safety Programs 1

.0ffice for Analysis and Evaluation 1

of. Operational Data

' FROM:

Theodore C. Cintula Reactor Systems Section GE and CE l

ej Reactor Operations Analysis Branch.

l Division of. Safety Programs.

p Office for' Analysis and Evaluation 4

of Operational Data J

-.4 d"

L

SUBJECT:

INADVERTENT PARTIAL: DRAINING OF CONDENSATE i

~

'J 4

' STORAGE TANK This technical review report completes my investigation into inadvertent l

c losses of inventory from condensate storage tanks. The investigation was-j prompted by an event at Browns Ferry-1, where 192,000' gallons of non-safety ~

s tinventory was' lost due to untimely responsive action. A review of other

?

events indicated the Browns Ferry event was typical of a previously l

established pattern'of CST draindowns,at BWRs, and these. operational

- events'did not affect plant safety.

l H

l gai8%M

_q Theodore C. Cintula i

Reactor Systems Section'GE and CE

1 L

Reactor Operations Analysis Branch Division of Safety Programs-Office for Analysis and Evaluation L

.of Operational Data

^

Enclosure:

As stated l

Distribution:

j PDRc JRosenthal MWillaims l

l CohtfalsF1MMa Edordan KBlack

~~

-ROAB R/F Dross RSavio, ACRS l

~ R/F TNovak MTaylor, EDO E

'/F LSpessard KRaglin, TTC a

GZech PBaranowsky, NRR pg

,~

SRubin l 10 NAE 0D R

SP:AEOD C OAB:DSP:AE0D

'b cula:mk ik JRosenthal 6/.//90 6/$/90 6/gy/90 l

p#

/

3A 9007090149 900627 BC RE WJM MW 4I nwco==gg y

j-s L

.