ML20055D057

From kanterella
Jump to navigation Jump to search
Certificate of Compliance 6144,Rev 11,for Model B-2
ML20055D057
Person / Time
Site: 07106144
Issue date: 06/22/1990
From: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To:
Shared Package
ML20055D053 List:
References
NUDOCS 9007030156
Download: ML20055D057 (4)


Text

.

__=_________________

l U.S. NUCLEAR RESULATORY C000bstSS60N l

I CERTIFICATE CF COCPLIANCE I

tacen ??

POR RADIOACTIVE MATEfilALS PACKACES l

e navisenes sa;uman c PAcxAos soewtiricAtiou muideen a PAoe uvideER

e. TOTAL NUMeER PAos's ~

l ta D reeeuussa 11 USA /6144/B( )

1 3

l q

'* 77eeneviceie is inued to certify that the peekooine and contenis doented in item 5 teiow, meets the applicabie **'ety standards set forth in l

of Fedevel Regulatene. Port 71.*Pacuging and Transportation of Radioactive Meierial."

j l

b. Then t.ortsfecate does not releeve the consignor from compliance with any reautrement of the regulations of the U S. Department of Transportation or other l

applicable re0uintory agenc6es, including the government of any country through or into wh6ch the peckage will be transported.

I I

I s.v a,c, g g s;ns yuetwe eases or a sArriv Awas,neg,tg,v,g,ggeys4ogo,agege,c,,,,

w c

I I

i I US-Ecology Nuclear Engineering Company Application I P.O. Box 7246 dated, December 21, 1979.

'l lLouisville, KY 40207 gqj pg l

a

4. oocacy wuween -)[.m u l

cart to is condational upon fulfilling the requirements of 10 CFR Part 71, as applicable, and the conditions specified below.

l l

S.

y+

l (a)

Packaging C

l

y w.y c l

~,

w 9

j s

. i<.'

I (1) Model o.:

B-2 l

i a

l (2) Description 7

i' I

y, w

~

s l

The p$ckaging: consists d'f'a rectangular,: double-walled box of welded 7

I

- mild ste'el coristruction with" dimensions 'of.'142. inc':es by 91 inches by I

54 inches high?which' enclose'st secbndary containers.~ The maximum I

weight'ofithe' loaded package'is142;000 pounds".

I y

, < w ~ m y a,

l The double-walled boxfconsistslof an outer 1-inch thick steel shell I

and'an inner 2-inch thick'steelishel1 ~ separated by 56 shock tubess eight on eachT,end, and ten 'n'each of the two(sides, top and bottom.

I o

I The shock tubes.are constructed of both 6-inch Schedule 40 and 8-inch l

Schedule 30 pipe. The tubes are 5 inches in length and are welded to I

the exterior of the# inner!boxL

  • V I

3 l

The cover of the outer box is secured by forty-six,1-1/4-inch diameter I

I high strength bolts. The lid of the inner box is sealed by two lengths l

I of Garlock single lip closure seals and the seal pressure is maintained y

I by steel springs which force the seal lip against the walls of the I

inner box.

l (3) Drawing I

I I

I I

The packaging is constructed in accordance with Kenasco Corporation g

l Drawing No.- 6901-002B and Bill of Material No. 6901-002C.

l l

l' l

I I

I I

I I

I I

I l

l l

9007030156 900622 a

I PDR ADOCK 07106144

__ _ ___ __ PDC _ ___ ___ _ ____ ___ _ ______ _ _ ___ _ _ __ ____

c

_ _ _ = -

i,

' % FC* WA CCCDMONS (contknuett) l Page 2 - Certificate No. 6144 - Revisicn No. 11-Dockee No. 71-6144 1

1 1

5. -

(b) Contents j

(1) Type and form of material l

l Radioactive material as solids, in normal or special form packaged 1

within DOT Specification 17H, 55-gallon steel drums, or other secondary I

containers which meet the requirements of DOT Specification Type A l

packaging, i

I (2) Maximum quantity of mater p

l e

l l

Ah ty of radioTc g/ material,nottoexceed Greater than T

)

5 watts and 5. d shoring.ounds including weight dfp[ contents, sec l

container (

l 6.

(a) For any packa ontaining water and/or organic substa which could I

L radiolytica enerate combustible gases, determination #f t be made by I

I p criteN['

urerheq by analysis of a rep ieritative' kage such that 11 tests and met over a period,

that s twice the l

J the follo expected g > ment tinle g

The rogen gener st be limited

-polar quanirft'r that would I

be 90 re than 5L v61umgl(ordquiYaJe6t' limits for 'dther inflammable I

Wtainer g%p,p,vptddf present a4}TP (i.e., no l

gasest of theTsecon L

morganOiO61]g-m41 f,1 eta g ta;afid,70[)',

a i

lIng m'

,b I

4.canr}M'r for tranyport,.the secondary h

-c WN A

For ag package 9dpifveredi e,

I contaber must bMrepped i shipme,nt in the same manner in which I

deterdic tion'for as

$hipment pjmiod begins I

when th6)packag&j g~ rgenerationb.is\\madeS.

twice the gxpected shipmentf time.g %@yst be (ompleted wi l

is prepared'(' sealed) an ge i

f vf)fp n%

l ForanypackageseIt I

exceeding that for' 41ning material's with radioactivit/ concentration not (b) ldwspecificactivitymaterial,$ahdshippedwithin10 I

days of preparation, or in,10 days after genting of drums or other j

3 secondary containers, t etpindiongt fiPabove need not be made, and i

the time restriction in (a) af,we does nd apply.

i I

7.

Dunnage must be provided in the shipping cask cavity sufficient to prevent I

movement of the secondary containers relative to the outer packaging under I

normal or accident conditions.

l l

l i

I I

I I

I l

I I

I I

l l

l I

w uc S onu ma 5 NUCLEt.A Edul ATORY CCMWWON l j

C M WMM l

I i

I i

i Page 3 - Certificate No. 6144 - Revision No.11-Docket No. 71-6144 i

1 1

i l

j 8.

In addition to the requirements of Subpart G of 10 CFR Part 71:

l t

l l

(a) Prior to each shipment, the inner and outer lid gaskets must be inspected.

I i

The gaskets must be replaced with new Garlock Model 23 Split Klozure if I

I inspection shows any defects or every twelve (12) months, whichever occurs l

I first.

I I

l (b) The package must be prepared for shipment, operated, maintained and l

i i

inspected in accordance wiht US Ecology, Inc. Procedure CSK-001, I

l Rev. O, dated May 2, 1990.

RE Use of packaging fabrica e g h ugust 31, 1 9.

6 ot authorized.

l 10. The package authorizqd4r ints certificate is hereby app ch for use under the i

general license pro M6ns of 'O CFR 571.12.

Q l

l 11.

Expiration dati.: June 230., 1993.

  1. h l

m Cr N)

K R:/

J l

l Q

I j f 0

k l

Nuclear Engineering $mpany applic$rQ.pv4

) Lc:;3979.

(*)

I, rt237 1oy dated Degem l

I g

p l

USEcologySupplemdntsdatedDecembag*N6 d1989 and i k g 1990,.

[._

I i

(f)

Qd1 v v-

$.2F w

.a'<

l i

4J t

4i%q

',q q t "h

$ ' NUCLEAR REGULATORY: COMMISSION

.I j

Way 4

4 I

i (s

c Ma n

yQ s

7 l

i I

. C#)

~

I l

Yp/,,

Charles E'.tMacDonAld, Chiff9 l

s TFafsporta' tion B'r'anch (v') '

'e l

Division of Safeguards.-

I V ~/

andTransportationfMMSS I

l l

JUN 2 2 1990

'd

" 5,. k,( 7 ~ g V A i

.i Date:

i l

I I

I I

I I

I I

l l

l i

i i

I I

I i

l i

l l

l l

l i

I i

!___------------------e-w-----------------------

i

UNITE D STATES

, f ' '

,, c

~g, l'

g NUCLEAR REGULATORY COMMISSION

p WASHINGTON, D. C. 20555
  • s.,...../

i APPROVAL RECORD Model No. B-2 Package Certificate of Compliance No. 6144 Revision 11 By application dated December 6, 1989, as supplemented on May 2, 1990. US-Ecology, Inc, requested that Certificate of Compliance No. 6144 for the Model No. B-2 package be renewed for a five year period.

No changes to the package design have been requested since the certificate was renewed on January 22, 1985.

The certificate has been conditioned to require that the package be prepared for shipment, operated, and maintained in accordance with US Ecology, Inc. Procedure CSK-1, Rev. O, dated May 2, 1990.

The certificate has been renewed for a five year term which expires June 30, 1995.

Je 14 ua Charles E. MacDonald, Chief Transportation Branch Division of Safeguards JUN 2 2 1990 and-Transportation, NHSS Date:

.