ON Commonwealth ECoon
- 1) One First Nitionsi Pl: a. Chicago. tilenois Addrtss Riply to: Post Office Box 767 v
Chicago, Illinois 60690 July 13, 1982 l
Mr. A. Schwencer, Chie f Licensing Branch #2 Division o f Licensing U. S. Nuclear Regulatory Commission l
Washington, DC 20555 l
Subject:
LaSalle County Station Unit 1 Revised Inservice Inspection Program NRC Docket No. 50-373 References (a):
L. O. De1 George letter to B. J.
Voungblood dated December 12, 1980.
(b):
L. O. DelGeorge letter to A. Schwencer dated September 1, 1981.
(c):
10 CFR 50.55a(g)(4)(1).
(d):
Operating License NPF-ll, dated April 17, 1982.
l
Dear Mr. Schwencer:
Reference (a) provided the NRC with the fourteen volame Preservice Inspection (Baseline) Program for Unit 1.
That program was based upon the 1974 Edition through Summer 1975 Addenda of the ASME Section XI code.
Reference (a) also provided Revision 0 of the i
l Unit 1 Inservice Inspection Program, which was prepared to the same code.
Since the submittal of Reference (a), several updates to the Preservice Inspection Program has also been provided.
S j
Reference (b) provided the NRC with the Unit 2 Preservice I'
l I
Inspection Program.
That program has been updated to include the l
requirements o f the 1980 Edition through the Winter 1980 Addenda o f d'**1kD the Code.
The Unit 2 Inservice Inspection Program has not been I
submitted to the NRC.
b >$T I
i I
Re ference (c) requires that the Inservice Inspection Program ".
.shall comply with the requirements in the latest edition and addenda of the Code incorporated.
.on the date 12 months prior to the date of issuance of the operating license.
Re ference (d), the operating license for LaSalle County Station, Unit 1, was issued on April 17, 1982.
It is also noted that the Summer, 1979 addenda was approved effective May 4, 1981 and the Winter,1980 addenda was approved ef fective on February 1,1982.
The Summer, 1981 addenda did not contain any technical changes and the Winter, 1981 addenda is not likely to be approved until 1983.
8207200220 820713
~~
PDR ADOCK 05000373 G
o-0 J.
G. Keppler July 13, 1982 Because LaSalle County Station is a 2 unit plant, and because of the obvious operational importance to have both units' programs based on the same code requirements, Commonwealth Edison has decioeo to utilize the Winter, 1980 addenda f or both units.
The re f o re, the LaSalle County Station Unit 1 Inservice Inspection Program has been upgraded to the Winter,1980 Addenda, even though it is a newer code than required by Reference (c).
Enclosed for your use are four (4) sets of the two volume Revision 1, Inservice Inspection Program, LaSalle County Station, Unit 1.
This submittal is being made at this time to allow an early initiation of your review of the program.
It should be noted that tabs 36 and 42 are currently incomplete.
The missing information is expected to be provided to you within the next two months.
As noted above, the Unit 2 Preservice Inspection Program has been updated to the requirements of the Winter, 1980 addenda.
The Unit 2 Inservice Inspection Program, which is being prepared to the requirements of Winter,1980 addenda, is expected to be submitted to you within the next four months.
If there are any questions in this matter, please contact this office.
Very truly yours, 7lIL]S t C. W. Schroeder Nuclear Licensing Administrator 1m cc:
NRC Resident Inspector - LSCS 4520N
-