Amend 52 to License DPR-66,waiving Normal Analog Rod Position Instrumentation Accuracy Requirements When RCS Below Normal Operating Temp
ML20055A867
Person / Time
Site: Beaver Valley
Issue date: 06/25/1982
From: Varga S
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20055A868 List:
References
NUDOCS 8207200077
Download: ML20055A867 (4)


Text

.

>#

  • E G g

'/

o, UNITED STATES l'

'i NUCLEAR REGULATORY COMMISSION g

.p WASHINGTON D. C. 20555

\\...../

DUQUESNE LIGHT COMPANY OHIO EDISON COMPANY PENNSYLVANIA POWER COMPANY DOCKET NO. 50-334 BEAVER VALLEY POWER STATION, UNIT NO. 1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 52 License No. DPR-66 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by Duquesne Light Company, Ohio Edison Company, and Pennsylvania Power Company (the licensees) dated June 16, 1982, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Comission; C.

There is reasonable assurance (1) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (11) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

8207200077 820e25 PDR ADOCK 05000334 p

PDR

. 2.

Accordingly, the license is amended by changes to tht Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. DPR-66 is hereby amended to read as follows:

(2) Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 52, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of the date of its issuance.

F THE NUC AR EGULATORY COMMISSION D,/

Q

\\

4 teven

adgl, f

Operating Reactors nch #1 Division of Licensi

Attachment:

Changes to the Technical Specifications Date of Issuance: June 25,1982 4

ATTACHMENT TO LICENSE AMENDMENT AMENDMENT NO. 52 TO FACILITY OPERATING LICENSE NO. DPR-66 DOCKET NO. 50-334 Revise Appendix A as follows:

3 1

Remove Page Insert Page 3/4 1-21 3/4 1-21 i

4 e

i h'

.. -,. - ~,,.,,

,- -. _== - -

REACTIVITY CONTROL SYSTEM POSITION INDICATION SYSTEM-SHUTDOWN LIMITING CONDITION FOR OPERATION 3.1.3.3 The group step demand counter and at least two analog rod position indication channels per group shall be OPERABLE for each group of shutdown or control rods not fully inserted.

APPLICABILITY: Modes 3*#, 4*# and 5*#

ACTION:

With less than the above required position indicator (s) OPERABLE, immediately insert all rods or, immediately open the reactor trip system breakers.

SURVEILLANCE REQUIREMENTS 4.1.3.3 Each of the above required position indicator (s) -shall be determined to be OPERABLE by performance of Specifications 4.1.3.2.1 and 4.1.3.2.2.

  • With the reactor trip system breakers in the closed position.
  1. The accuracy requirements of the analog rod position indication system are not applicable below Tavg of 547F due to known shift of the calibration of the analog rod position indication system at reduced plant temperatures. At plant temperatures below Tavg = 547F, the analog rod position indicators shall be used to provide general guidance in determining rod position and the group demand l

indicators shall be used to determine exact rod positions. The requirements set forth in 4.1.3.2.2b must be performed at a nominal average coolant temperature of 547F. During preparations for startup, the requirements of 4.1.3.2.2b may be waived until a nominal coolant temperature of 547F is reached. This exclusion l

for monitoring the analog to demand accuracy within the Rod Position Indication System at temperatures below 547F is applicable pending resolution of the analog RPI drif t between Duquesne Light and the NRC. This issue is expected to be resolved during July 1982. During this interim period, any rods which are not fully inserted (those partially or fully withdrawn) should be assumed to be fully withdrawn when Keff and the critical boron concentration are being cal culated. Resolution of the analog RPI drift must be completed and this interim period expires no later than September 1,1982.

BEAVER VALLEY - UNIT 1 3/4 1-21 Amendment tio. 52 e

,