f n%,
UNITED STATES
~f g,C ij NUCLEAR REGULATORY COMMISSION ATOMIC SAFETY AND LICENSING BOARD PANEL 000ETED 1 5 J1 ff W ASHINGTON. O.C. 20555 USHRC 1,'
.4 f Ju1y 15, 1982 T2 J1L 16 NO:29 crM OF EPt Dr.
00C AE,i M !, EERVh...
33ANCH MEMORANDUM FOR:
Chairman Palladino SERVED JUL161982 Commissioner Gilinsky Commissioner Ahearne Commissioner Roberts Commissioner Asselstine FROM:
John H Frye, III Administrative Judge
SUBJECT:
SUA SPONTE ISSUES IN CINCINNATI GAS &
ELECTRIC COMPANY, ET AL. (WM. H. ZIMMER NUCLEAR POWER PLANTT DOCKET NO. 50-358 This is to inform you that the Licensing Board presiding in the above proceeding has exercised its authority pursuant to 10 CFR 11 2.718(j) and 2.760a to reopen the record and raise sua sponte eight new contentions that were initially advanced by the Miami Valley Power Project, an Intervenor in this pro-ceeding.
These contentions relate to quality assurance practices at the Zimmer Station and Cincinnati Gas & Electric Compan'y's character and competence to operate a nuclear station.
We have exercised our sua sponte authority to raise thc;a issues because we do not believe MVPP has made a strong enough showing under the Rules of Practice to entitle it to introduce late contentions and because we believe that resolu-tion of these serious safety concerns on the record and in full public view would be in the public interest.
Our Memorandum and Order which sets forth our reasoning is attached hereto.
The contentions are set out in an Appendix to that Memorandum and Order.
1
/
i 1
A tiv udge Chairman, Atomic Safety and Licensing Board for the 8207190292 820715 Zimmer Operating License PDR ADOCK 05000358 G
PDR proceeding
Attachment:
As stated cc:
Zimmer Service List Office of the General Counsel 35 02.