Department of Energy Washington, D.C. 20545 Docket No. 50-537 HQ:S:82:051 JUL 0 31982 i

Mr. Paul S. Check, Director CRBR Program Office Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C.

20555

Dear Mr. Check:

SUBMITTAL 0F PSAR REFERENCE Enclosed are 70 copies of PSAR Reference QCS 760.140-1, ASME Publication PVP-63, "A Procedure to Evaluate Structural Adequacy of a Piping System in Creep Range,"

by A. K. Dhalla.

This report is provided as part of the response to HRC Question CS 760.140, submitted June 30, 1982.

Sincerely, nbUb Ok v

John R. Longene r

Acting Director, ffice of the Clinch River Breeder Reactor Plant Project Office of Nuclear Energy Enclosure cc: Service List Standard Distribution

/

Licensing Distribution gl 8207090121 820706 PDR ADOCK 05000537 A