B ALTIMORE G AS AND ELECTRIC COMPANY P.O. BO X 14 7 5 B A LTIM OR E, M A R YL A N D 212o3 Antwun E. LUNOVALL JR.

v.cs >=es. cant s-.

June 22,1982 U.S. Nuclear Regulatory Commission Docket Nos.

50-317 Region 1 50-318 631 Park Avenue License Nos.

DPP--53 King of Prussia, PA 19406 r,t'R-69 ATTENTION:

R. W. Starostecki, Director Divison of Project and Resident Inspections Gentlemen:

This refers to your Inspection Report 50-317/82-07; 50-318/82-07, which transmitted one item of apparent noncompliance with NRC requirements. Enclosure (1) to this letter is a written statement in reply to those items noted in your letter of May 24,1982.

Should you have further questions regarding this reply, we will be pleased to discuss them with you.

Very truly yours, Vice President - Supply AEL/DWL/gla Enclosure cc:

J. A. Biddison, Esquire G. F. Tros.hridge, Esquire D. H. Jaffe, NRC R. E. Architzel, NRC B207070137 820629 gDRADOCK 05000317 PDR 1

Mr. R. W. Starostecki June 22,1982 Page 2 STATE OF MARYLAND TO WIT:

CITY OF BALTIMORE C. H. Poindexter being duly sworn states that he is Vice President of the Baltimore Gas and Electric Company, a corporation of the State of Maryland; that he provides the foregoing response for the purposes therein set forth; that the statements made are true and correct to the best of his knowledge, information, and belief; and that e was authorized to provide the response on behalf of said Corporati WITNESS my Hand and Notarial Seal:

tcf/L jeug Notary Publice

  1. 1 /,/ /,, / ((N, My Commission Expires:

y3~

v

ENCLOSURE (1)

REPLY TO APPENDIX A OF NRC INSPECTION REPORT 50-317/82-07; 50-318/82-07 Item 1 Calvert Cliffs Instruction ll2C, " Safety and Safety Tagging," requires that af ter the completion of a job, a Tagging Authority person shall remove the tag (s), reposition the equipment to the cleared tag position, initial and date the tag-out record, and instruct another person to inspect the equipment and ensure it is in the proper position. On May 1,1982, a tag on the handswitch for //22 service water pump was removed and the equipment restored to its cleared position without the required documentation by the Tagging Authority and without indication that an independent check was performed until May 5,1982.

Clearing of the tags and the physical verification were performed in accordance with the procedure.

The cause of the event was the failure of Tagging Authority personnel to document the restoration of //22 Service Water Pump and its associated verification. To ensure that this event will not recur, CCI-112C and CCI-307, " Operations Shift Turnover Checklist,"

will be modified to provide a means for a Senior Reactor Operator to perform and document a daily review of the documentation associated with tag-outs initiated and closed out during the previous day. This change will be in effect prior to August 1,1982.

.