Final Deficiency Rept Re Incomplete Documentation & Radiographs of Rolled Plate Pipe,Initially Reported on 820524.Deficiency Not Reportable Per 10CFR50.55e
ML20054J685
Person / Time
Site: River Bend Entergy icon.png
Issue date: 06/18/1982
From: Booker J
GULF STATES UTILITIES CO.
To: Jay Collins
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
10CFR-050.55E, 10CFR-50.55E, RBG-12-860, NUDOCS 8206290438
Download: ML20054J685 (1)


Text

e GULF STATES UTILITIES COMPANY POST OFFICE D o x 2 9 *> 1 . DEAUMONT. 7EXAS 77704 AREA CODE '113 838 6631 June 18, 1982 RBG- 12,860 File Nos. G9.5, G9.25.1.1 Mr. John T. Collins, Regional Administrator U. S. Nuclear Regulatory Commission Region IV, Office of Inspection and Enforcement 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011

Dear Mr. Collins:

River Bend Station Unit 1 Docket No. 50-458 Final Report /DR-53 On May 24, 1982, Gulf States Utilities Company (GSU) notified the Nuclear Regulatory Commission's Region IV Office of a condition potentially reportable under 10CFR50.55(e) concerning B. F. Shaw rolled plate pipe rejected for incomplete documentation and radiographs (DR-53). GSU has completed its review and determined that the deficiency is not reportable under 10CFR50.55(e). This concludes GSU's resp *onse on this subject.

Sincerely, b

/.J. E. Booker Manager-Engineering & Licensing River Bend Nuclear Group

/kt-cc: Director of Inspection & Enforcement U. S. Nuclear Regulatory Commission Washington, D. C. 20555 _ gj VIsq@Ll{3!

b 49 \ n' A* C B2062904:B B2061B PDR ADOCK 05000458 S PDR