i JUN 2 41982 Docket No. 70-01994 License No. SNM-1635 Steven's Institute of Technology ATTN: Dr. Steven Sylvester Radiation Safety Officer Castle Point Station Hoboken, New Jersey 07030 Gentlemen:
Subject:
Inspection No. 82-01 This refers to the special safety inspection conducted by Mrs. Teresa Hall Dardan of this office on June 1, 1982 of activities authorized by NRC License No. SNM-1635 and to the discussions of our findings held by Mrs. Darden with yourself at the conclusion of the inspection.
This inspection was limited to a review of those activities conducted under your license relating to plutonium / beryllium (PuBe) sealed sources. The Department of Energy has identified PuBe sources with end caps not welded in place and has recommended appropriate nondestructive examination of the outer end cap welds of all PuBe sources. The inspector visually examined the welds of your PuBe source.
No apparent defects were identified; however, the inspector also discussed the advantages of conducting additional nondestructive tests by qualified personnel and appropriate radiation safety precautions during such tests. A wipe sample was taken from each end cap weld area and was analyzed in our Regional Office Laboratory.
This analysis identified no significant removable radioactive contamination, which is in agreement with your leak test results.
Within the scope of this inspection, no violations were observed.
In accordance with Section 2.790 of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regulations, a copy of this, letter will be placed in the Public Document Room.
No reply to this letter is required.
Your cooperation with us in this matter is appreciated.
Sincerely, Original 518 ped B14 Hya
- c. AMPAl2-L-Thomas T. Martin, Director Division of Engineering and Technical Programs 0FFICIAL RECORD COPY 8206290355 b' 1 hDRADOCKO N4 PDR
M%Kf3Plf:ED%df Steven's Institute of Technology 2
JUN 2 4 1982 1
i cc:
1 Public Document Room (PDR)
Nuclear Safety Information Center (NSIC)
State of New Jersey bcc:
Region I Docket Room (with concurrences)
Chief, Operational Support Section (w/o encl) l L
RI:DETF RI:DETP Darden Kinneman/ntm 6/22/82 0FFICIAL RECORD COPY l
_ _ _ _ _ _ _ _ _.