ML20054H940

From kanterella
Jump to navigation Jump to search
Interim Deficiency Rept Re Inadequate Design/Design Review of Instrumentation Seismic Support Drawings.Mercury Co Rework of Deficient Supports Incomplete.Final Rept Will Be Submitted by 820802
ML20054H940
Person / Time
Site: Waterford Entergy icon.png
Issue date: 06/17/1982
From: Mclendon G
LOUISIANA POWER & LIGHT CO.
To: Jay Collins
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
10CFR-050.55E, 10CFR-50.55E, W3K82-0354, W3K82-354, NUDOCS 8206250232
Download: ML20054H940 (1)


Text

LOUISIANA f 242 ottanoNot sinen POWE R & L1G HT/ P O BOX 6008

  • NEW OnLEANS. LOUISIANA 70174 * (504) 366-2345 E?lth s*<sYOj June 17, 1982 G. D. McLENDON Senior Vice President W3K82-0354 Q-3-A35.07.20 Mr. John T. Collins, Regional Administrator, Region IV -

U. S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 1000

$)h  !

Arlington, Texas 76012 '#' i JUN 2 2 EE2 .i i l

SUBJECT:

Waterford SES Unit No. 3 Docket No. 50-382 ( j, h Significant Construction Deficiency No. 20

" Inadequate Design / Design Review of Instrumentation Seismic Support Drawings" Third Interim Report

Reference:

1) LP&L Letter W3K81-0432 to NRC dated December 3, 1981
2) Telecon - L. Martin (NRC) to L. Bass (LP&L) on June 16, 1982

Dear Mr. Collins:

In reference (1) LP&L committed to submit a final report on the subject Significant Construction Deficiency by June 15, 1982.

Ebasco Nonconformance Report W3-2333 addresses this problem and is being used to track corrective action. Mercury Company is in the process of reworking supports which were identified as being deficient. At this time rework is not complete.

It is anticipated that the corrective action will be complete and a Final Report submitted by August 2, 1982.

Very truly yours, GDMcL/LLB/ncd ,

cc: 1) Director Office of Inspection & Enforcement U. S. Nuclear Regulatory Commission Washington, D. C. 20555 b

2) Director Y'

Office of Management 2 Information and Program Control U. S. Nuclear Regulatory Commission Washington, D. C. 20555

~

8206250232 820617 PDR ADOCK 05000382 S PDR 1