ML20054H682

From kanterella
Jump to navigation Jump to search
Part 21 Rept Re Pneumatic Actuator Yoke Failure.List of Other Projects W/Similar Equipment Encl
ML20054H682
Person / Time
Site: Perry, 05000000, Hartsville, Phipps Bend
Issue date: 06/18/1982
From: Adam Wilson
HENRY PRATT CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
REF-PT21-82 NUDOCS 8206240326
Download: ML20054H682 (3)


Text

- - - _ _ _ _ _ _ _ _ _

TEIJsi' lit )NI? ll2 H81 -M M X ) TEIJ0X 72(bI2-4 i

HENRY PRKPT COMPANY creative engirice inig ibi-fit si(1 systenis

-101 MOl7I'll f ilGIll.\\ND.WENUIC AUltOltA, IIJ JN( >18 (W Wr7 June 18,1982 Nuclear Regulatory Commission Region 3 Office 799 Roosevelt Road Glen Ellyn, Illinois 60137 Attn; Mr. James G. Keppler, director Office of Inspection and Enforcement

Subject:

Non-Compliance Reporting Under 10CFR, Part 21 Section 206 of Energy Reorganization Act of 1974.

Dear Mr. Keppler:

Pursuant to Pratt letter of June 15, 1982 regarding pneumatic actuator yoke failure, Pratt and G. H. Bettis have identified other projects with similar equipment as listed on Attachments 1 & 2.

Very truly yours, h N. NN A. K. WILSON Vice President Manager of Engineering AKW:pst CC:

B. R. Cummins R. D. Nelson l

G. A. Kurkjian l

H. C. Schwenk T. Cer9 Attachment #2 Cleveland Eletric - Attn:

Ronald Farrell, Quality Assurance Manager Attachment #1 Tennessee Valley Autharitv - C. A. Chandley, Mechanical Engineering Branch KOhd$o JON 211982 lc)

PDR

- Mhd.

10CFR, Part 21 ATTACHMENT 1

Report of June 18, 1982 Nuclear Plants - TVA Hartsville #1, 2, 3 & 4; Phipps Bend #1 '& 2; Customer P. O. No. 77K25-820750-1 Actuator - G. H. Bettis Model No. NT 310B-SR12 Valve Size 24" Pratt Butterfly Valve VALVE TAG NOS. P38-FF001 A & B Pratt Order-Item No.

Quantity 0151-1 2

D154-1 2

0157-1 2

D160-1 2

D163-1 2

D166-1 2

VALVE TAG NOS:

X73-FF006 A & B X73-FF007 A & B X73-FF008 A & B X73-FF010 A & B Pratt Order-Item No.

Qua nti t_y l

D151-3 8

l D154-3 8

i D157-3 8

D160-3 8

D163-3 8

D166-3 8

.~.

i

.10CFR, Part 21 i

1 Report of June 18,1982 ATTACHMENT 2 i

Nuclear Plant - Cleveland Electric Illuminating Co.

Perry Unit 1 & 2 Customer P. O. No. P-1248-K

- Actuator - G. H. Bettis Model No. T312-SR2 J

Valve Size - 24" Pratt Butterfly Valve i

Valve Tag Nos:

1 I

RNP-2-lM14-F055 A & B l

RNP-2-lM14-F060 A & B RNP-2-2M14-F055 A & B i

RNP-2-2M14-F060 A & B Pratt Order.

Item No.

Quanti ty D0086-2 8

.i i

i i

i i

i

~

9 i

i r

i