ML20054H646
| ML20054H646 | |
| Person / Time | |
|---|---|
| Site: | 07000296 |
| Issue date: | 06/21/1982 |
| From: | Martin T NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| To: | Arthur D FAIRLEIGH DICKINSON UNIV., TEANECK, NJ |
| References | |
| NUDOCS 8206240292 | |
| Download: ML20054H646 (2) | |
Text
.
JUN 21582 Docket No. 70-00296 License No. SNM-275 Fairleigh Dickinson University ATTN: Dean Wallace Arthur Radiation Safety Officer "O River Road 3
eck, New Jersey 07666 Gentlemen:
Subject:
Inspection No. 82-01 This refers to the special safety inspection conducted by Mrs. Teresa Hall Darden of this office on June 4,1982 of activities authorized by NRC License No. SNM-275 and to the discussions of our findings held by Mrs. Darden with yourself at the conclusion of the inspection, and to a subsequent telephone discussion between yourself and Mrs. Darden on June 13, 1982.
This inspection was limited to a review of those activities conducted under your license relating to plutonium / beryllium (PuBe) sealed sources.
The Department of Energy has identified PuBe sources with end caps not welded in place and has recommended appropriate nondestructive examination of the outer end cap welds of all PuBe sources. The inspector visually examined the welds of your PuBe source.
No apparent defects were identified; however, the inspector also discussed the advantages of conducting additional nondestructive tests by qualified personnel and appropriate radiation safety precautions during such tests. A wipe sample was taken from each end cap weld area and was analyzed in our Regional Office Laboratory. This analysis identified no significant removable radioactive contamination, which is in agreement with your leak test results.
It is our understanding that you wish to dispose of the source via the Savannah River Operations.
Within the scope of this inspection, no violations were observed.
In accordance with Section 2.790 of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regulations, a copy of this letter will be placed in the Public Document Room.
No reply to this letter is required. Your cooperation with us in this matter is appreciated.
Sincerely, Original Signed By:
John D. Kinneman Thomas T. Martin, Director Division of Engineering and Technical Programs 8206240292 820621 0FFICIAL RECORD COPY (M AIDCK 070** g
/f.' 07
a JW 2 1 1982 Fairleigh Dickinson University 2
cc:
Public Document Room (PDR)
Nuclear Safety Information Center (NSIC)
State of New Jersey bec:
Region I Docket Room (with concurrences)
Chief, Operational Support Section (w/o enc 1)
W V
- RI:DETP
- i. RI:DETP Darden Kinneman/ntm
/If9
0FFICIAL RECORD COPY
)
L