p%Iv;,L.;_;; Ci am Cortified 2.7
'gp CPU Nuclear d *): lKMh hhf E
P O Bor 480 -
Metetowa Pennsyt,anG 17057 717-944 7621 Ar!1er s U"ect Dial Numt,e-June 4, 1982 4400-82-t-0094 Office of Inspection and Enforcecent Attn:
R. C. Haynes, Director Region I U. S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, Pennsylvania 19406
[
Dear Sir:
Three Mile Island Nuclear Station, Unit II (TMI-II) b Operating License No. DPR-73 Docket No. 50-320 Licensee Event Ecport No. 82-20 This letter is to confirtr. the conversation between Mr. G. A. Kunder, Unit II Plant Operations Review Committee Chairman, and Mr. R. J. Conte, Senior Resi-dent Inspector, Unit II, nn Program Office, which took place at 1630 hours0.0189 days <br />0.453 hours <br />0.0027 weeks <br />6.20215e-4 months <br /> on June 3, 1982.
A condition considered prompt reportable under Technical Specification 6.9.1.8.(i) was determined to exist at 1500 hours0.0174 days <br />0.417 hours <br />0.00248 weeks <br />5.7075e-4 months <br /> on June 3,1982.
At this tire it was determined that the recent everflov of the Auxiliary Buil-ding sump occured due to an influx of rainwater from the Borated I?ater Storage Tank Recirculation Pump Enclosure Sumr.
This condition arose as a result of deficient administrative and design controls associated with the BWST Recircu-lation Pumn Enclosure Sump.
This condition was determined to need remedial corrective action.
Details vill be included in the follow-up report.
5incpre,1y)
(
./
M C
J. 3.'Earton
,/
(Acting) Director, D'.I-II JJB:JCA:hjb I
cc:
L. H. Barret, Deputy Progr ::n Director R. Conte, Senior Resider.t in:,pector D:!-II i
l 8206220091 820604
~
PDR ADOCK 05000320 S
PDR i
G:_ %: ea s s ut t-e Genn Put t i;' + s 5, s w --