ML20054E094

From kanterella
Jump to navigation Jump to search
Amend 70 to License DPR-20,clarifying Implementation of App a Tech Specs Re Shutdown Margin Requirements W/Less than Four Primary Coolant Pumps Operating
ML20054E094
Person / Time
Site: Palisades 
Issue date: 04/14/1982
From: Crutchfield D
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20054E095 List:
References
NUDOCS 8204260132
Download: ML20054E094 (4)


Text

-

UNITED STATES gb 7

NUCLEAR REGULATORY COMMISSION n

g f1

,g WASHINGTON, D. C. 20555

$.Ik.)

CONSu!4ERS POWER COMPAriY DOCKET NO. 50-255 PALISADES PLANT AMENDMENT TO PROVISIONAL OPERATING LICENSE i

i Amendment No. 70 License No. OPR'-20 1.

The Nuclear Regulatory Commission (the Comission) has found that:

A.

The application for amendment by Consumers Power Company (the licensee) dated May 5,1980, i

complies with the standards and requirements of the Atomic Energy Act of.1954, as amended (the Act), and the Comission's rules and regulations set forth in 10 CFR Chapter I; i

B.

The facility will operate in conformity with the application. the.

provisins of the Act, and the rules and regul6tions of the Comission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public; and (ii) that such activities will be conducted in compliance with the Comission's regulations; l

D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; l

and E.

The issuance of this amendment is in accordance with 10 CFR Part i

t 51 'of the Commission's regulations and all applicable requirements have been satisfied.

l i

~

t 8204260t%

2.

Accord;ngly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment and Paragraph 3.B of Provisional Operating License No., DPR 20 is hereby amended to read as follows:

Techr.fcal Specifications

~

The Technical Specifications contained in Appendix A as revised through Amendment No. 70 are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of the date of its issuance.

FOR THE NUCLEAR REGULATORY COMMISSION at.M Dennis M. Crutchfield Chief Operating Reactors Branch #5 Division of Licensing

Attachment:

Changes to the Technical Specifications l

Date of Issuance:

April 14,1982 e

i 1

l l

l 1

e

ATTACHMENT TO LICENSE AMENDMENT NO. 70 PROVISIONAL OPERATING LICENSE N0. DPR-20 DOCKET NO. 50-255 Revise Appendix A Technical Specifications by removing the following page and by inserting the enclosed page. The revised page contains the captioned amendment number and marginal line-indicating the area of change.

PAGE 3-58 O

e i

I l

~

~

3.10, CONTROL ROD AND POWER DISTRIBUTION LIMITS Applicability Applies to operation of control rods and hot channel factors during operation.

Objective To specify limits of. control rod movement'torassu're'an: acceptable power distriblution 'during power. operation,. limit worth of individual rods to values analyzed for accident conditions, maintain adequate shutdown

, margin _ af.ter-a reactor-trip and to specify acceptable power limits for power' tilt conditions'.~~

Specificat' ions 3.10.1 Shutdown Ma'rgi'n'Rsqsirements.

a.

Wi~th four primary coolant pumps in operation at hot shutdown and above, the shutdown margin shall be.2%. -

. - - - ~.

.b.

With less than four primary coolant pumps in operation at hot shutdown and above, boration shall be immediately initiated to increase and maintain the shutdown margin at 23.75%.

c.

At less than the hot shutdown condition, boron c'oncentration shall'be shutdown boron concentra't' ion'.:

d.

If a control rod 'cannot.be trippe'd, shutdo'wn. margin shall be increased by boration as necessary to compensate for the worth of the withdrawn inoperable rod.

e.

The drop time of each control rod shall be 'no greater than 2.5 seconds from the beginning of rod motion to 90% insertion.

3.'10.2 Individual Rod Worth The maximum worth of any one rod in the core at rated power shall be a.

l equal to or less'than 0.6% in reactivity.

b.

The maximum worth of any one rod in the core at zero power shall be equal to or less than 1.2% in reactivity.

3.10.3 Power Distribution Limits The linear heat generation' rate at the peas power Elevation z shall a.

(

not exceed:

15.28 kW/Ft x F (Z) for ENC Fuel Types 14.12 kW/Ft x F (Z) f r D Type Fuel A

where the function F (Z) is shown in Figure 3.9.

If the power dis-A tribution is double peaked, both peaks shall satisfy the criterion.

Appropriate consideration shall.be given to the following factors:

l (1) A flux peaking augmentation factor of 1.0, (2) A measurement calculational uncertainty factor of 1.10, 3-58 AmendmentNo.2T,f3',)f,70,

.