Subject:
LaSalle County Station Units l'anldc7
\\N Response to I.E.Bulletin 82-01 NRC Docket No s.
50-373 and 50-374 Re ferences (a):
C.
Schroeder letter to A.
Schwencer cated March 25, 1982, " Associated Piping and Engineering Corporation Alteration o f Radiographs o f Welos in Piping Subassemblies" (b):
I&E Inspection Repo r t 82-13, dated April 1, 1982.
(c):
I.E.
Bulletin 82-01, " Alteration o f Radiographs o f Welds in Piping Subassemblies"
Dear Mr. Keppler:
The purpose of this letter is to provide Commonwealth Edison Company's response to Reference (c).
As was explained in Re ference (a), Commonwealth Edison Company received advance notice of this problem in mid-February.
As a result o f this information, Commonwealth Edison Quality Assurance performed Q.A. Su rveillanc e 82-16 3 and 82-17 6.
On March 17, 1982, Q.A.
Surveillance 82-163 cetermined that:
" Associated Piping and Engineering Corp. (AP&E) supplied radiographs to General Electric (G.E.) for replacement spools in the recirculation loop at LaSalle Station Units 1 and 2.
The subject radiographs were reviewed to determine the following:
1.
That required T holes are visible and discernible.
2.
That the T holes have not been enhanced or altered.
This was accomplished by viewing the radiographs in a high intensity viewer (to discern required T hole), and f ull overhead lighting at an oblique angle to the viewers line o f vision (to assure no alterations were present).
After a critical review, no alterations or enhancements were observed.
Based on this review, code acceptability o f the subject spools (S/N's 1,2,3, 4,5,6,7,8,9,10,11,15,16, 17,18,19,20,21,22, & 24) is not in
,]{f[/
ouestion."
s 8204220445 920409 nPR 161981, C)
PDR ADOCK 05000373 0
e.
p.
J..G.
Keppler April 9, 1982 i
Following this Q.A. surveillance, your staf f performed a 25% audit of the same material (Reference (b)) and likewise deter-mined that the acceptance criteria for this review had been met.
On March 29, 1982, Q.A. Surveillance 82-176 determined that:
" Associated Piping & Engineering Corp. ( AP&E) supplied radiographs to General Electric (G.E. ) for replacement safe end nozzles in the recirculation system at LaSalle Station Unit 1.
The subject radiographs were reviewed to determine the following:
s 1.
That the required T holes are visible and discernible.
2.
That the T holes have not been enhanced or altered.
This was accomplished by viewing the radiographs in a high intensity viewer (to discern required T hole), and full overhead lighting at an oblique angle to the viewers line o f vision (to i
assure no alterations were present).
After a critical review, J
no alterations or enhancements were observed.
Based on this review, code acceptablity on the subject spools (S/N's 6991 i
through 7002 inclusive) is not in question."
This letter fulfills the prescribed actions 1, 4, and 5 of Reference-(c).
Actions 2 and 3 are not required for LaSalle County Station.
To the best of my knowledge and belief the statements contained herein are true and correct.
In some respects these j
statements are not based upon my personal knowledge but upon infor-i mation furnished by other Commonwealth Edison employees.
Such information has been reviewed in accordance with Company practice j
and I believe it to be reliable.
i If you have any further questions in this matter, please contact this office.
}
Ve ry truly yours, l
Chyk,pa,.
!~
C. W..Schroede r Nuclea r LicensL g Administrator i.
Im cc:
Director, Of fice o f I&E, Washington, D.C.