ML20054C791
| ML20054C791 | |
| Person / Time | |
|---|---|
| Site: | Clinch River |
| Issue date: | 03/29/1982 |
| From: | Stark R Office of Nuclear Reactor Regulation |
| To: | Check P Office of Nuclear Reactor Regulation |
| References | |
| NUDOCS 8204210658 | |
| Download: ML20054C791 (4) | |
Text
.
March 29,1982 Docket No.: 50-537 MEMORANDUM FOR: Paul S. Check, Director, CRBR Program Office, Office of Nuclear Reactor Regulation FROM:
Richard M. Stark, Project Manager, CR8R Program Office, Office of Huclear Reactor Regulation
SUBJECT:
CLINCH RIVER BREEDER REACTOR TMBDB REVIEW MEETING DATE &
LOCATION:
April 16, 1982, Air Rights Building, Room 2242, Bethesda, Md., at 8:30 a.m.
PURPOSE:
Continue the Thermal Margin Beyond Design Basis (TMBDB) review. See Agenda.
PARTICIPANTS:
Department of Energy J. Longenecker, D. Goeser, et. al.
NRC J. Lor.g. T. Walker, T. Butler (LHAL), R. Gasser (BNL),
D. Powers (Sandia), R. Stark, et. al.
original signea by:
Richarr1M.Staric Richard M. Stark, Project Manager CRBR Program Office Office of Nuclear Reactor Regulation l
l
Enclosure:
As stated cc: Service List l
l 8204210658 820329 PDR ADOCK 05000537 A
PDR mo
..CBilN.Nll..M.
omce>
..BS.tdrMac.....0Ihp.s.s..........
suRuno
.3.4.2pe8,2....... 3.(d.82.,,,
om>
NRC FORM 318 O0@) NRCM om OFFICIAL RECORD COPY usam miem
Office of the Executive Suite 600 Legal Director Washington D.C.
20006 c
U. S. Nuclear Regulatory Commission Eldon V. C. Greenberg Washington, D.C.
20555 Tuttle & Taylor 1901 L Street, N.W.
William B. Hubbard, Esq.
Suite 805 Assistant Attorney General Washington, D.C.
20036 State of Tennessee Office of the Attorney General L. Ribb 450 James Robertson Parkway LNR Associates Nashville, TN 37219 Nuclear Power Safety Consultants 8605 Grimsby Court William E. Lant:'ip, Esq.
Potomac, MD 20854 City Attorney Municipal Building P. O. Box 1 Oak Ridge, TN 37830 George L. Edgar, Esq.
=
1800 M Street, N.W.
Washington, D.C.
20036 Herbert S. Sanger, Jr., Esq.
General Counsel Tennessee Valley Authority Knoxville, TN 37902 Chase Stephens, Chief Docketing and Service Section Office of the Secretary U. S. Nuclear Regulatory Commission Wasnington, D.C.
20555 Raymond L. Copeland Project Management Corp.
P. O. Box U Oak Ridge, Tennessee 37830
.. l cc:
Dr. Cadet H. Hand, Jr., Director Barbara A. Finamore Bodega Marine Laboratory S. Jacob Scherr University of California Ellyn R. Weiss P. O. Box 247 Dr. Thomas B. Cochran Bodega Bay, California 94923 Natural Resources Defense Council, Inc.
Daniel Swanson 1725 I Street, N.W.
Office of the Executive Suite 600 Legal Director Washington, D.C.
20006
~
U. S. Nuclear Regulatory l
Commission Eldon V. C. Greenberg l
Washington, D.C.
20555 Tuttle & Taylor 1901 L Street, N.W.
William B. Hubbard, Esq.
Suite 805 Assistant Attorney General Washington, D.C.
20036 State of Tennessee Offi.ce of the Attorney General L. Ribb 450 James Robertson Parkway LNR Associates Nashville, TN 37219 Nuclear Power Safety Consultants 8605 Grimsby Court William E. Lantrip, Esq.
Potomac, MD 20854 City Attorney Municipal Building P. O. Box 1 Oak Ridge, TN 37830 George L. Edgar, Esq.
Morgan, Lewis & Backius 1800 M Street, N.W.
Washington, D.C.
20036 Herbert S. Sanger, Jr., Esq.
General Counsel Tennessee Valley Authority Knoxville, TN 37902 Chase Stephens, Chief Docketing and Service Section Office of the Secretary U. S. Nuclear Regulatory Commission Washington, D.C.
20555 l
Raymond L. Copeland Project Management Corp.
l P. O. Box U l
Oak Ridge, Tennessee 37830 l
l
I f
AGENDA FOR TMBDB MEETING WITH NRC APRIL 16, 1982 INTRODUCTION /0VERVIEW Status of Extreme Penetration Analyses o Containment Conditions o Structural Evaluation TEST PROGRAM o Limestone Concrete Test o Prototypicality Considerations o Sandia Hedl Comparison CACECO CODE Discussion Addressing Other Identified Areas o Pu Source from Sparging o Consequence of Basemat Penetration o Sodium Hydride Effects o Qualification of TMBDB Instruments o Sodium as a Source of Radiation
P 1
.y Distribution Docket File bec: Applicant Service List NRC PDR Local PDR NSIC CRBRP0 File H. Denton D. Eisenhut R. Vollmer R. Mattson S. Hanauer o
A H. Thompson D
J. P. Knight W. Johnston
,2 eff# g D. Muller v-9 P. Check Y
R. W. Houston r
1, JF S
g L. Rubenstein
<.?'
F. Schroeder g?-
M. Ernst g
4 ACRS (16)
~
OI&E (3)
S. Treby (0 ELD)
V. Moore B. Grimes R. Woodruff Region II Administrator
.m ED0 (4)
L. S. Tong NRC Participants J. A. Olshinski, Reg. II R. E. Ireland, NRC-Idaho J. Austin B. D. Liaw l
J. Glynn i
P. Wood l
Receptionist - Phillips Bldg.
CRBR Staff J. Long R. Jackson Charlie Thayer, Reactor Training Center, Chattanooga l
l l
l