si. %..,evi= at,.,U.,

i e.

e at.i I

(*

.c...... u.. c... A o.w s..u.n AMENDMENT OF SOLICITATION /MODiflCATION OF CONTRACT I

4

...c n m

o..... i o s e.f e..a 0 %1.anODK3C it.6g NO 3 If flCis71 Dill 3

.t ou.irt.O.4. P up.

e fe'setCT O 8,8 71 8./..

ggg' 111.lDuf bt )

1 Five (5) g

, Oo,

. A, _,,......

,,,.6..,~...a

,,,,,, i U.S. Nuclear Regulatory Commission Division of Contracts Washington. DC 20555 1 (ON1.AC10.

LODE l l

IMil1TY LUDE l S

NAM ( AND ADDetl$

Auf NDuf Nf Of O soi'caa' oN No F'

l Purdue Research Foundation ouro n.,ar a n Division of Sponsored Programs

,5,,,,.,,.

O' ',p,;""-

Hovde Hal1 of Administration

@ UE.U',',O.o '. Na NRC-03-80-102 ca West Lafayette. IN 47907 L

J

/23/80 g,,. a,,,

9 THis.1OCE AP,Ltti ONLT IO AulNDMiNT5 Of SOLICif AflONS O n.

6-.

-i-.a

i. -.aa. '..- u.a i s.

. -a. O -....ad

n. 6 a 4.-

-.ru ' ~..' o..

O...~.a

~ia.......,.

....~~~..

.a.........ru

.~aa..,

....s...u.-.~

m i,....a..

g 6 :,,.a

.i.,......

6... ~ a ~

. - 6..,,., n..... 6 4.. d... i. i e, -,..... i..

.6.. l..

l. d e. e n te.e.

S e..t

.......d.

.d be... F AtLU.E OF YOU. ACENOWLE DG(uf NT 10 et.f Cliv!D AT THE l.$UING OFFICE Pelo.10 tHE HOU. AND our srecmeo NA,.isuu N ern ci ON O, v0U. Orei.. ee. 6,..

n.

. a...,,,...............i....

6~. a.. 6... ~, 6.

a. 6, w.....

.. a

.. i.....o.....i.............s.

i..

.a..

a-..a

... a.

..,,,,, 6..a........r.a u,.ccOUN1,No ANo A,,.Or..i>ON o.i A m,,y,,a, 31X0200.202 20-19-10-12-03 B6836 OBLIGATE:

$182,754.00 II. THf1 40CK AP,L'E5 ONLY TO MOD 6f eC AfiONS Of CONT. ACTS /O.DE.1 m

n.. ci ',. c'......a

n. ci u.a u.

.s.

6....

6..

..u..

i..a...

m v.

. 6..a....or

.... a r.

..r..

,s

.....s..

6..

...s.....

,.,...r.....

..... e........i 6i.a is i.i @ n.. s.,,i.-

.i A......

...... 4

.........,,.. _ ttleJiiutua l_a greement-of--t he-pa rties-and-Art-icle 2

.a.r.

.s.

6...

6..a.

..o...

... u.a 2. entitled " Changes" of the Genera 1 Provisions.

12 DIscaiP110N OF AMENDMIN1, MODS..CAleON 1.

Article I - Description of Work, is hereby amended by deleting Part B. Objective, in its entirety and substituting the following in lieu thereof:

"B.

Objective g

To provide the NRC staff with an evaluation of common fundamental processes and/or phenomena operative in the accident scenario, in order to estimate ru n l

the consequences of potential thermal interactions and core melt accident gg progressions for the specific reactors under staff review; and to provide input for the key licensability issues."

l 9m6

)

@M 2.

Article I - Description of Work, Part C. Fork Required, Task I - Energetic Thermal

&,gg Interactions, is hereby amended by deleting Paragraph A. in its entirety and substituting the following in lieu thereof:

at i omo cwx am.z

" A.

Establish the key phenomena in the thermal mechanisms which are pertinent for the related fuels and coolants for specific nuclear i

m m... u a 6.......n......a..a....

.. 6,4-

..g...a i u.a... 6.

e...

6..,s.

a,,

..a.a

..... a...o.

u.

c Ni..cio.iO e NOT.t oui.to

_3

. c O,,ts,0,ssu.~s O.,,c

. % ~ 9C.

coy,,,g,g,,g,,g,g,,3,,gy,,o,o 3,gy

,,,3 oggy,, y,,yp,,,y,y s _

t-

\\

MM RESEARCH f 0UN'WtCN

f' j

(

M is

..a gj oc. g c N >.Daa.,

j

.a.N... O, _,.

,1,,...,....,

,....,. ~,.

N. a e -,, m.....,,,.....,

...... ~,

Vice President for Pregams

.3 /N,2.-

Mary Jo Mattia 3' ?. 'd N i Rctert A. Greenkorn i

Page 2

/

power plants involved in specific licensing actions.

This includes identification of core and coolant conditions which would lead into energetic thermal interactions and fuel-coolant contact mechanisms which would determine the type and severity of interactions."

3.

Article I - Description of Work, Part C. Work Required Task 1 -

Energetic Thermal Interactions, is hereby further amended by incorporating Paragraphs C and D as follows:

"C.

Prepare testimony input for the Indian Point Hearing.(HIP) in the area of steam-explosions. A letter report is due on this on February 8, 1982.

D.

Prepare final draft-input to Appendix C of update NUREG-0850

' Assessment of Core Melt Accidents at the Zion and Indian Point Huclear Power Plants and Strategies for flitigating Their Effects (Z/IP Report).'

A letter report on this is due June 30, 1982."

4.'

' Article I - Description of Work, Part C. Work Required, is hereby amended by deleting Task II - Recriticality, in its entirety and substituting the following in lieu thereof:

" Task II - Molten. Core Accident Progessions A.

The contractor shall identify and estimate core-melt interactions

.phenomenology resulting from thermally-induced material motion and its potential consequences for the specific nuclear power plants involved in specific licensing actions.

The contractor

~

shall perform small simulant-material tests as necessary to investigate the possible modes to justify the conclusions and I

recommendations.

B.

Review and evaluate, in detail, Section 3, ' Degraded Core Phenomena' and Section 4,' Transient Analysis' of the ' Zion l

Probabilistic Safety Study (ZPSS)' noting areas of agreement, areas of disagreement and areas where more information is l

needed from the utility.

Concentrate on those aspects that I

the Contractor believes have a major impact on the accident l

consequences.

A written report on this is due January 15, 1982.

C.

Subsequent to meetings with the utilities on key areas (the meetings will be held in January) prepare a final evaluation of Sections 3 and 4.

A written report on this is due February 12, 1982.

i Page 3 D.

Prepare testimony input for the Indian Point Hearing (HIP) in the areas of thermally-induced material motion (basemat penetration and debris bed coolability). A letter report on this is due February 8,1982.

E.

Prepare final draft-input to Appendix B of update NUREG-0850 Z/IP Report.

A letter report on this is due June 30, 1982."

5.

Article I - Description of Work, Part D. Reporting Requirements is hereby amended by deleting Paragraph 2 in its entirety and substituting the following in lieu thereof:

" 2.

Monthly progress letters shall be submitted within ten (10) days following the month reported on (two copies each) to the attention of the following individuals:

Mary Jo Mattia, Contracting Officer Roger J. flattson, Director, DSI J. fleyer, DSI Project Officer S. Boyd, DSI B. Grenier, NRR This letter report will include, but not be limited to, the following:

a..

Funds committed during the previous month and cumulative expenditures to date.

The first such report of each contract year will include a monthly projection of expenditures for the next twelve (12) months.

b.

Brief description of the work accomplished in the month, and projected activity for the next month, c.

Any problems or delays which may have been experienced or can be foreseen and specific recommendations for action to facilitate the execution of the contract work."

The above changes are accomplished at no additional cost to either party and with no change in the time required for contract performance.

6.

Article IV - Consideration, Part A. Estimated Cost, Obligation of Funds, is hereby amended by deleting Paragraphs 2 and 3 in their entirety and substituting the following in lieu thereof:

~

Page 4 "2.

Total funds currently available for payment and allotted to this contract are $512,754.00.

As this contract is fully funded, Article 3 entitled ' Limitation of Funds' of the General Provisions is superseded by Article 4 entitled

' Limitation of Cost' of the General Provisions.

3.

It is estimated that the amount currently allotted in Paragraph 2 above will cover performance of the contract through January 22, 1983."

7.

Article VI - Project Officer, is hereby amended as follows:

"The Technical Monitor and Project Officer for this contract is J. F. Meyer."

em.m a

w m m