APR 2 1982 DOCKET NO: 70-293G APPLICANT: Mississippi Power & Light Company (MPL)
FACILITY:
Grand Gulf Nuclear Station, Unit 1
SUBJECT:
REVIEW OF LICENSE AMENDMENT APPLICATION DATED MARCH 4, 1982, AND ITS REVISION DATED MARCH 23, 1982 I.
Background
By application dated March 4, 1982, Mississippi Power & Light Company (MPL) requested authorization to receive, possess, inspect and use fourteen (14) neutron sources enriched in Sb-124 with up to 2800 curies / source. The sources were to be received in two (2) shipping casks with seven (7) sources in each cask. The neutron sources will replace the 14 Sb-124 sources (source strength up to 1400 curies / source) previously licensed to MPL under their SNM-1882 license. By letter dated March 23, 1982, MPL submitted a revised application requesting the authorization with all 14 sources to be received in a single cask.
II. Radiation Safety It is estimated by the reactor operators in Idaho (EG&G) the maximum dose rate will be 60 millirem per hour at the surface of the shipping cask and 6 millirem per hour (in air) at 3 feet from the cask. All operations related to the handling of the shipping cask and/or its contents are performed in accordance with approved written procedures. Radiation protection personnel are responsible for establishing radiologically l
controlled areas and are continuously present during all source handling operations. Moreover, the MPL ALARA Comittee reviews the source handling operations to identify exposure reduction opportunities and I
establishes ALARA goals.
III. General The amendment application and its revision were discussed with Mr. A.R.
Wagner, Region II (Resident IE), and with Mr. M. D. Houston (NRR Project Manager). Neither one foresaw any safety or environmental related problem with authorization for the larger neutron sources, l
l
\\
t
\\
0204160066 820405 PDR ADOCK 07002 C
e omcc)
' " ' " " ^ " ' >
DATEk OFFICIAL RECORD COPY j
""C'
"*'**'""C"
i l APR 2 1982 IV. Conclusion and Recommendation The receipt, possession, inspection and use of the neutron sources will have no adverse effect on the health and safety of the operating personnel, the public or the environment.
The staff recommends approval of the requested authorization.
c riginal Signed by 7 Cot:1ech Norman Ketzlach Uranium Process Licensing Section Uranium Fuel Licensing Branch Division of Fuel Cycle and Material Safety, f#iSS Dri ical signod By:
G Approved by:
k W. T. Crow, Section Leader DISTRIBUTION:
Docket File 70-2936 50-416 50-417 PDR NMSS r/f FCUP r/f NKetzlach (2)
LTyson LFDale, MPL DHouston Region II JRobertson RErickson JBlaylock WTCrow ARWagner, RES IE LJEvans
/
7.h).if.e.F.CUF.,.h.\\'.
..F.C U P....gM'..
"'c'>..F.CV.P::
.NKe.tzlach/.c J.LTyson...
.. WTCrow.....
"">.. 4/.E /.8.2.....4.l.br82......... 4 /.c./ 82..,
'""C'
"""~*'""C" OFFICIAL RECORD COPY