Forwards Request for Addl Info Re 820302 Application for Approval of Model R Packaging.Submittal Schedule Should Be Provided within 30 Days
ML20053E479
Person / Time
Site: 07109161
Issue date: 05/27/1982
From: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To: Payne A
GULF NUCLEAR, INC.
References
NUDOCS 8206080414
Download: ML20053E479 (3)


Text

,

]/-9/(,,/

P MAY 2 71982 eb G nA

~

FCTC: RHO 71-9161 Gulf Nuclear, Inc.

ATTN: Ms. Ann E. Payne 202 Medical Center Blvd.

Webster, TX 77598 Gentlemen:

This refers to your application dated March 2,1982, requesting approval of the Model No. R packaging.

In connection with our review, we need the information identified in the enclosure to this letter.

Please advise us within thirty (30) days from the date of this letter when this infomation will be provided. The additional information requested by this letter should be submitted in the form of revised pages. If you have any questions regarding this matter, we would be pleased to meet with you and your staff.

Sincerely, Originni Signed by GARLES E. MACDONALD Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety, NMSS l

Enclosure:

As stated 9

^

Distribution: w/enci 4

RH0degaarden (2)

DTHuang QEqg,,11 h'

JU.V() 4 E82A-Q-WHLake

~

c CRMarotta 9 C%

l Docket File kL D

3pp NRC PDR IE HQ y

Region IV o3 b

NMSS R/F m

FCTC R/F en ""

a L ' e' "t

'C nhTd' 3

..x "iis7/i'isi"'"65/ili/8T

  • "$/3/8F

'U6/Xj7sf""

'65Wsf '

B20bOBO414 B20527

~~

~

~. -

~

- - ~

G OFFICIAL RECORD COPY C

\\/

Gulf Nuclear. Inc.

Model No. R Packaging

{

Docket No. 71-9161 Encl to ltr dtd: MAY 2 7 fM)

DRAWINGS 1.

It is not apparent from the drawing how the radiographic device will be secured within the overpack. Provide a drawing which shows the general arrangement, dimensions, and materials of construction of the insert retainer.

2.

Provide an engineering drawing showing dimensions and the specifications i

for the 10-gallon drum, lid, and bolt closure ring.

STRUCTURAL 1.

The requirements of 10 CFR 571.32(a) for load resistance should be addressed.

2.

The requirements of 10 CFR 571.35 for the normal conditions of transport should be addressed (including protection to the urethane foaminsidethedrum).

3.

Evaluate the performance of the lock ring bolt for the 30-foot drop test followed by the 40-inch puncture test. The consequence of bolt damage, if any, for a drop onto the bolt must be considered in terms of any reduction in package effectiveness.

4.

Justify that the radiographic device tested within the overpack represents the weakest design (structurally) and the drop orientations chosen represents the worst case for the subsequent fire test.

This should take into consideration bottoming out of the urethane foam and protrusions on the radiographic devices planned to be shipped in the overpack.

4 t

"' c ' >

our)

'"^c""*"'""C" OFFICIAL RECORD COPY

i o

i

,# i THERMAL 1.

Provida vent holes which are sealed for normal conditions of transport, but allow release of decomposition products of foam in a fire environment for both the radiographic devices and the overpack.

2.

Provide assurance that the package was not artificially cooled at the end of the 1/2-hour fire test (including a description of how the fire was extinguished at the end of the fire test).

SHIELDING Provide radiation profile results bebre and after the tests at the surface and 36 inches from the surface of package.

OPERATING PROCEDURES Provide proposed operating and maintenance instructions for use of the package. This should include steps taken to assure proper closure of the package and monitoring of radiation levels.

1 1