Final Deficiency Rept Re Possible Overpressure of Piping, Initially Reported on 820430.RHR Sys Piping Between Inboard Isolation Valve 1E12F009 & Outboard Isolation Valve 1E12F008 May Be Exposed to Elevated Temp.Mod to Be Complete 821231
ML20053D860
Person / Time
Site: Zimmer
Issue date: 05/25/1982
From: Borgmann E
CINCINNATI GAS & ELECTRIC CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
10CFR-050.55E, 10CFR-50.55E, QA-1777, QA-17777, NUDOCS 8206070390
Download: ML20053D860 (2)


Text

.o pz

.g> ;g;g

$ i ky:

THE CINCINNATI GAS & ELECTRIC COMPANY CFl ~

CINCINN ATI. OHIO 45201 E A. BORGM ANN st Neon vict ent siorNr May 25, 1982 OA-1777 U.S. Nuclear Pegulatory Ccmnission Pegion III 799 Roosevelt Ibad Glen Ellyn, Illinois 60137 Attention:

Mr. J. G. Keppler Regional Administrator RE:

WM. H. ZIbMER NUCLEAR POVER STATION UNIT I 10CFR50.55 (e) - ITEM M POSSTRTE OVERPRESSURE OF PIPING - DOCKER NO. 50-358, CONSTRUCTION PEFMIT NO. CPPR-88, W.O. #57300, JOB E-5590, FILE NO. NRC-8, M-44 Gentlemen:

'Ihis letter constitutes a final report concerning the subject design deficiency initially reported to the Ccmnission on April 30, 1982, under the requirements of 10CFR50.55(e).

Piping in the Zimner Residual Heat Pcmoval (RH) Systs between inboard isolation valve lE12F009 and outboard isolation valve lE12F008 may be exposed to elevated ambient conta.inment tmperatures during design IOCA conditions.

Since the valves are nonnally closed, thermal expansion of water in the piping could cause an overpressurized condition resulting in possible pipe rupture and leakage of contaminated fluid in the Peactor Building.

Engineering Change Request (ECR) #389 has been written and approved to install a relief valve between the two valves. It is expected that work to implement this fix will be cmpleted by December 31, 1982.

8206070390 820525 PDR ADOCK 05000358 S

PDR JUN 1 1982 1E 2'l ',b

I a

Mr. J. G. Keppler Regional Administrator May 25, 1982 - QA-1777 Page 2 We trust the above will be found acceptable as a final report under 10CFR50.55(e).

Very truly yours,

'IEE CINCINNATI GAS & ELECIRIC COMPANY

^

,r_? -- -

er E. A. BORGMANN SENIOR VICE PRESIDENT FKP:ec cc: NRC Resident Inspector Attn:

W. F. Christianson NBC Office of Inspection and Enforcenent Washington, D.C. 20555 4

I i

-, ~-

e

,-e,

,