M(

LAv Orraces TUTT AND KODNEll 873 WENT MADINON MTHEET SUITE 1004 CIIICAGO, ILLINOIS 60609 NON A Ln TuTT as e/ sea-isaa JAN L. KODNER FREEDOM OF INFORMATION ACI REQUESI March 30, 1982 Fora-P.1-M P 68ue. 'd 4-/-n U.S. Nuclear Regulatory Commission Director, Division of Rules and Records Office of Administration Washington, DE 20555 Gentlemen:

Pursuant to the Freedom of Information Act, as amended, 5 USC 552, and the Privacy Act of 1974, 5 USC 552A, I hereby request a copy of any and all documents relative to the Commonwealth Edison construc-tion of two nuclear lower plants in LaSalle, Illinois, Docket Nos.

50373 and 50374, as :lercinafter specified.

Construction problems, defects, lack of adherence to government con-struction codes or standards, relating to, but not limited to, the following:

1.

Concrete defects, including honeycombing, especially honeycombing of the Units 1 and 2 reactor pedestals and primary containment structures; improper pouring pro-cedures; improper procedures for vibrating of concrete; improper procedures during concrete setting, especially concrete setting too fast; improper mixing of concrete.

2.

Failure to remove debris from forms before pouring concrete, debris including wood, barrels, metal, plas-tic tarps, etc.

3.

Improper assembly of steel rod reinforcing structures, especially indiscriminate or excessive cutting of assembled structures.

4.

Poor quality welding of pipes and other structures, including failure to seat pipe ends prior to welding, visible pipe leaks, welds with open gaps containing only weld material, lack of adherence to pipefitting or weld-ing codes, poor quality contral, lack of inspection or radiography of welds.

8206070203 820330 PDR FOIA KODNER 82-168 PDR

~

.U.S. Nuclear Regulatory Commission Director, Division of Rules and Records Page 2 March 30, 1982

{

l 5.

Improper or incomplete mortaring of high-density concrete block structures, including use of poor quality mortar or mortar with improper proportions of ingredients.

6.

Covering up with concrete of ends of pipe inserted into main reactor containment structures for strengthening cable to te passed through.

7.

Cracks or other defects in the stack or the steel supports for the stack.

8.

Any and all explosions, including, but not limited to, explosions in the area of the top of reactor 1; explosions which blew off either the reactor lid or the lid the re-actor refueling pit; explosions which blew a hole in the reactor building roof; ' explosions resulting from purging, pressurization or depressurization tests of the contain-ment structures.

9.

Sabotage by construction workers.

10.

Fraud by construction companies or Commonwealth Edison personnel.

11.

Deaths or maiming injuries to construction workers.

If you determine that some portions of the requested information are exempt:

1.

Please provide me with a copy of the remainder of the file; 2.

Advise of the specific exemptions which you think justi-fies your refusal to release the information; and 3.

Inform me of your agencies appeal procedures.

As you know, the amended ar

  • permits you to waive or reduce the fees if that "is in the public int. rest because furnishing the information can be considered as primarily benefitting the public".

I believe

)

that this request plainly fits this category; and, accordingly, re-quest that you waive any fees.

If your agency elects not to waive said fees, please advise of the costs involved.

1 1

______________-J

(

A U.S. Nuclear Regulatory Commission Director, Division of Rules and Records Page 3 March 30, 1982 l

As provided for in the amended act, I shall expect to receive a reply i

within ten (10) working <1ays.

Thank you for your cooperation.

Very truly yours, h

o-M

. Kodner Attorney for Citizens Against Nuclear Power, Inc.

JLK/v1 I

1

.