Donald A. Wells Macapr ouaMy Asw ance (313! 237 % 57 Edison =000Second Avenuew 2 May 21, 1982 EF2-58071:

Mr. James G. Keppler, Regional Administrator Region III U.S. Nuclear Regulatory Ca mission 799 Roosevelt Road Glen Ellyn, Illinois 60137

Subject:

Final Report of 10CFR50.55(e) Item on Thermal Growth Clearance for CRD Penetrations Between Biological Shield and the. Primary Containment (#44)

Dear Mr. Keppler:

This is Detroit Edison's final report on the Thermal Growth Clearance for CRD Penetrations between Biological Shield and the Primarf Containment.

problem. This problem was originally reported to Mr. J. Konklin of NRC Region III by Detroit Edison's Mr. G.J. Carter, OA Engineer - Construction Quality Assurance, on May 28, 1981.

At that time, it was determined that there was questionable clearance to allow for thermal growth of the primary containment vessel with respect to the CRD penetration in the Biological Shield. Reactor Controls, in empleting installation of the CRD lines, noted instances where the speci-fled slope of the CRD lines had been exceeded.

The work has been ccmpleted. The final configuration of penetrations X-37A, X-37B, X-37C, and X-37D has been approved by Edison Engineering via As-Built ABC-65.

l l

If you have questions concerning this matter, please contact Mr. H.A. Walker, Supervisor-Construction Quality Assurance.

Very truly yours, DAW / HAW /cp cc: Mr. Richard DeYoung, Director Office of Inspection and Enforcement Division of Reactor Inspection Programs i

U.S. Nuclear Regulatory Cmmission Washington, D.C. 20555 Mr. Bruce Little, Resident Inspector U.S. Nuclear Regulatory Comission 6450 North Dixie Highway Newport, Michigan 48166

  1. 0 8206040277 820521 PDR ADOCK 05000341 MAY 2 81982 S