ML20053C180
| ML20053C180 | |
| Person / Time | |
|---|---|
| Site: | Waterford |
| Issue date: | 05/20/1982 |
| From: | Mclendon G LOUISIANA POWER & LIGHT CO. |
| To: | Jay Collins NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) |
| References | |
| 10CFR-050.55E, 10CFR-50.55E, Q-3-A35.07, W3K-82-0289, W3K-82-289, NUDOCS 8206010552 | |
| Download: ML20053C180 (1) | |
Text
LOUISIANA 342 octanoNoe s1nter POWE R & LiGH T P O BOX COO 8
- NEW ORLEANS LOUISIANA 70174 * (504) 366-2345 N0!dsh$NU May 20, 1982 G. D McLENDON Senior Vice President W3K-82-0289 Q-3-A35.07 Mr. John T. Collins, Regional Administrator, Region IV U. S. Nuclear Regulatory Connission 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76012
Subject:
Waterford SES Unit No. 3 Docket No. 50-382 Final Report of Potentially Reportable Deficiency No. 78
" Dimensional Deviation in Bolting Material - Site Purchase Orders"
Reference:
Telecon - R. Bennett (LP&L) to L. Martin (NRC) on 4/19/82
Dear Mr. Collins:
Evaluation of the significance of Potentially Reportable Deficiency No. 78 has been completed in accordance with 10CFR50.55(e), and this item is considered nonreportable.
The results of our review are on file at the Waterford SES Unit No. 3 Site and are available for your inspection.
If you have any questions, please let us know.
Very truly yours, A. ht '
GDMcL/LLB/grf cc:
- 1) Director Office of Inspection & Enforcement x
U. S. Nuclear Regulatory Commission Washington, D. C. 20555 s
- 2) Director h8fp Office of Management Information and Program Control i
U. S. Nuclear Regulatory Commission Washington, D. C. 20555 820 6 010 T 5C2 b