DOCKET NO. 50-281 UNIT SilUTDOWNS AND POWER REDUCTIONS uni r NAME Surry Two DATE 03-08-82 Q
REPORT MONT11 February, 1982 COMPLETED BY Vivian 11. Jones -
TELEPilONE (804) 357-3184 ext. 477 D
h O
. 's a
.E. E 3
yIE Licensee Eg ga'L Cause & Corrective
{
No.
Date
[
5g il 2s5 Event g?
gu3 Action to y5 jg Report *r mO Present Recurrence F
g d
82-9 02-01-82 S
0.0 11 4
Load followed on instructions of the system operator.
82-10 02-04-82 S
0.0 11 4
Load followed on instructions of the system operator.
82-11 02-11-82 F
0.0 A
4 50-281/82-014/
IB INSTRU Excore Detector N-41 f ailed causing 03L-0 ci turbine runback. De-energized O.'
detector and bypassed rod drop-turbine runback features.
82-12 02-16-82 S
0.0 11 4
load followed on instructions of'the system operator.
82-13 02-23-82 F
4.9 11 3
the reactor tripped on an over-temp-erature-overpower AT signal following trip of the 11. P. drains pump.
a The Instrument Dept. calibrated loop
&T's following startup.
I 2
3 4
F: Forced Reason:
Method:
Exhibie G-Instructions S' Scheduled A. Equipment Failure (Explain) 1-Manual for Preparation of Data B. Maintenance or Test
- 2. Manual Scram.
Entry Sheets for Licensee 3-Automatic Scram.
Eveni Report (LER) File INUREG.
C. Refueling D Regulatory Restriction 4-Other (Explain) 0161)
E-Operstor Training & Iicense Examination 5
F Administrative Exhibit I Same Source G-Operational Error (Explain) 19/71)
Il Other (Explain)
.