ML20053B032

From kanterella
Jump to navigation Jump to search
Summary of 820406-10 Meetings W/Doe, TVA, Pmc,Westinghouse & ORNL in Bethesda,Md Re Matl Data Base & Special Matl Considerations for High Temp Design of Crbrp Components
ML20053B032
Person / Time
Site: Clinch River
Issue date: 05/11/1982
From: Stark R
Office of Nuclear Reactor Regulation
To:
Office of Nuclear Reactor Regulation
References
NUDOCS 8205270655
Download: ML20053B032 (4)


Text

l e

E i

N(E

%y May 11, 1982 f Y2a j~

s a sh ::au ad"W84

.A

.a Docket tio.:

60-537 r

k4 to APPLICAllT: Department of Energy, TVA and Pi1C w

/

FACILITY:

Clinch River Breeder Reactor SudJECT:

Sul4%RY OF APRIL 6 AIID 7 CRBR REVIEW MEETIliGS On April 6 and 7,1932, a meeting was held in Bethesda, Maryland to discuss the materials data base and special materials considerations for high tunperature design of CRBRP components. The lists of attendees are attached to this summary.

The applicants' presentation included a discussion of:

the CRBRP lleat Transport Systeu materials data base; the feature tests which verify the data base; environmental effects due to sodium and radiation; special materials and stress considerations, including fracture mechanics, i

metallurgical notch, elastic followup, and weld residual stresses; recent A5flE code changes; transition joint experience and technology in LWRs, LhFORs, and fossil plants; and specific design, material, and structural considerations of the transition joints in CRBRP.

The staff questions in the Materials and Hechanical Engineering areas are documented in the 210 and 250 series questions which have been sent to the applicants for formal responses.

ny.-tunt W 07:

,,.-,mouu k l

l Richard M. Stark, Project Manager l

CRBR Program Office Office of 14uclear Reactor Regulation l

l

Enclosure:

As stated I

Distribution cc: Service List Docket File CRBR Reading 8205270G5h ne CRBRP,0hM

,CR, pgT(R]

suo m e> RS,ta.r.h/.M... k.Th.d, u,.....,..,.,,.,,.,..,,.,.,,.,,.,..,,,.,.,.

o,nc,,

5!..\\.l.82

.Nl!!.l0.2.........

ouny

........ ~........... ~.

unc rcau sia tio-con nacu o24o OFF1CIAL RECORD COPY useo:ini-mem

y 4

, cc:

Dr. Cadet H. Hand, Jr., Director Barbara A. Finamore Bodega Marine Laboratory S. Jacob Scherr University of California Ellyn R. Weiss P. O. Box 247 Dr. Thomas B. Cochran Bodega Bay, California 94923 Natural Resources Defense Council, Inc.

Daniel Swanson 1725 I Street, N.W.

Office of the Executive Suite 600 Legal Director Washir.gton, D.C.

20006 U. S. Nuclear Regulatory Comission Eldon V. C. Greenberg Washington, D.C.

20555 Tuttle & Taylor 1901 L Street, N.W.

William B. Hubbard, Esq.

Suite 805 Assistant Attorney General Washington, D.C.

20036 State of Tennessee Office of the Attorney General L. Ribb 450 James Robertson Parkway LNR Associates Nashville, TN 37219 Nuclear Power Safety Consultants 8605 Grimsby Court William E. Lantrip, Esq.

Potomac, MD 20854 City Attorney Municipal Building P. 0. Box 1 Oak Ridge, TN 37830 George L. Edgar, Esq.

Morgan, Lewis & Bockius 1800 M Street, N.W.

Washington, D.C.

20036 Herbert S. Sanger, Jr., Esq.

General Counsel Tennessee Valley Authority Knoxville, TN 37902 Chase Stephens, Chief Docketing and Service Section Office of the Secretary V. S. Nuclear Regulatory Comission I

Washington, D.C.

20555 Raymond L. Copeland l

Project Management Corp.

l P. O. Box U Oak Ridge, Tennessee 37830 i

/

ATTENDEES Materials Meeting on April 6, 1982 R. Stark NRC E. D. Uldrich EG&G Idaho H. Lowell Magleby EG&G Idaho T. K. Burr EG&G Idaho S. N. Hou NRC R. J. Bosnak NRC G. Clare Westinghouse, Oak Ridge J. Porowski 0'Donnel & Associates, Pittsburgh, Pa.

M. Badlani 0'Donnel & Associates, Pittsburgh, Pa.

B. O'Donnell O'Donnel & Associates, Pittsburgh, Pa.

C. Brinkman ORNL, Oak Ridge, Tn.

J. Siegel CRBRP/P0, Oak Ridge, Tn.

J. M. Corum ORNL, Oak Ridge, TN G. H. Nickodemus W-ARD, Pittsburgh, Pa.

D. Robinson CRBRP/PO, Oak Ridge, Tn.

D. Hornstra CRBRP/P0, Oak Ridge, Tn.

W. E. Ray W-ARD, Waltz Mill Site R. Mallett W-ARD, Waltz Mill Site A. Cappucci NRC B. Copp EG&G Idaho, Bethesda, Md.

D. Becker NRC A. Giger LANL, Los Alamos, NM i

D. Moran NRC L. A. James Westinghouse Hanford Co., Richland, WA C. Bigelow 00E, Germantown, Md.

P. T. Falk W-ARD, Waltz Mill Site J. Swift NRC i

S. J. Bhatt NRC H. B. Holz NRC i

I l

l

~ -., - - ~ - -

r, t

ATTENDEES Materials & Mechanical Meeting on April 7,1982 R. Stark f4RC H. Lowell Magleby EG&G Idaho, Idaho Falls, ID E. D. Uldrich EG&G Idaho, Idaho Falls, ID T. Burr EG&G Idaho, Idaho Falls, ID l

S. Hou NRC B. Bosnak NRC R. H. Mallett W-ARD, Waltz Mill B. O'Donnell O'Donnell & Associates, Pittsburgh, Pa.

M. Badlani 0'Donnell & Associates, Pittsburgh, Pa.

J. Foroumi 0'Donnell & Associates, Pittsburgh, Pa.

D. Robinson CRBRP/P0, Oak Ridge, Tn.

G. Nickodemus W-ARD, Waltz Mill M. Manjoine W 'R&D, Pittsburgh, Pa.

J. M. Corum ORNL, Oak Ridge, Tn L. L. France W-AESD, Large, Pa.

J. M. Siegel CRBRP/P0, Oak Ridge, Tn.

J. M. Weaver W-0ak Ridge, Tn.

W. E. Ray W-ARD, Waltz Mill Site S. J. Bhatt NRC F. Litton NRC A. Cappucci NRC D. Hornstra CRBRP/P0, Oak Ridge, Tn.

T. Wehner LANL, Bethesda K. Jaquay Rockwell-ESG, Canoga~ Park, CA J. Swift NRC D. Peters CRBRP/P0, Oak Ridge, Tn.

C. Bigelow 00E, Germantown, Md.

A. K. Dhalla Westinghouse-ARD, Madison, Pa.

H. B. Holz NRC D. Moran NRC A. Giger LANL, Los Alamos, NM

'g 5

e Distribution

/ Docket File bec: Applicant Service List

_ NRC PDR Local PDR NSIC CRBRP0 File H. Denton D. Eisenhut R. Vollmer R. Mattson S. Hanauer H. Thompson J. P. Knight W. Johnston D. Muller P. Check R. W. Houston L. Rubenstein i

F. Schroeder M. Ernst ACRS (16)

OI&E (3)

S. Treby (OELD)

V. Moore B. Grimes R. Woodruff Region II Administrator ED0 (4)

L. S. Tong NRC Participants J. A. Olshinski, Reg. II t

R. E. Ireland, NRC-Idaho J. Austin B. D. Liaw J. Glynn P. Wood Receptionist - Phillips Bldg.

CRBR Staff J. Long R. Jackson Charlie Thayer, Reactor Training Center, Chattanooga l

T. Walker I

1

_,y y

r-,

,-.-,g

..-...-_--w-_-._,

--m

.,