U. S. NUCLEAR REGULATORY COMMISSION REGION I Report No.
70-820/82-05 Docket No.70-820 License No.
SNM-777 Safeguards Group 1
Licensee:
United Nuclear Corporation Wood River Junction Rhode Island 02894 Facility Name:
United Nuclear Corp., Recovery Systems Inspection At:
Wood River Junction, Rhode Island Inspection Conducted:
April 16, 1982 Date of Last Material Control and Accounting Inspection January 28, 1982 Type of Inspection:
nnourced Materia _1 Control and Accounting Inspector 7
6 /8. 6 C I. Coh'en', CSEmi date Approved by:
[
/
6 /2 OC A. T. Gody, Chief, uards Section, date Technical Program B nch Inspection Summary: Announced inspection on April 16, 1982 (Inspection Report No. 70-820/82-05)
Area Inspected:
Status of Decommissioning Activities. The inspection involved 4 inspector-hours on site by one NRC inspector and began during regular hours.
Results: The licensee was found to be in compliance with NRC requirements in the area inspected.
i 8205270136
DETAILS 1.
Persons Contacted
- R. Gregg, Plant Manager
- K. Helgeson, Manager, Nuclear and Industrial Safety
- denotes those present at exit interview.
2.
Licensee Action on Previous Inspection Findings (Closed) Unresolved (78-17-02):
The licensee completed a review of significant shipper-receiver differences between UNC Navy and UNC Wood River Junction and reconciled the outstanding differences.
3.
30703 - Exit Interview The inspector met with licensee representatives (denoted in Paragraph 1) on April 16, 1982. The inspector summarized the scope and findings of the inspection.
4.
92713 - Status of Decommissioning Activities No violations were identified. The inspector toured the fuel processing indcar storage and outside areas of the facility and held discussions with the licensee in regard to the status of decommissioning activities. 1he processing area was stripped of all equipment and initial cleaning was per formed. A three foot square grid was being prepared on the floors and walls, as a reference for surface survey measurements, which were scheduled to be completed during May,1982.
The inspector indicated that Region I may perform an independent survey of the processing areas after the licensee completes their survey.