MAY 0 5 1992 License: 42-01512-01 Western Company of North America Western Petroleum Services ATTN: James Huie President P. O. Box 186 Fort Worth, TX 76101 Gentlemen:
This refers to the routine safety inspection conducted by Mr. N. M. Shopenn of this office on March 16 and 17, 1982, April 12, 13, and 26, 1982, of the dctivities authorized by the NRC Byproduct Material License 42-01512-01 and to the discussion of our findings held by the inspector with members of your staff at the conclusion of the inspection.
The inspection was an examination of the activities conducted under the license as they relate to radiation safety and to compliance with the Commission's rules and regulations, and the conditions of the license. The inspection consisted of selective examinations of procedures and representative records, interviews of personnel, independent measurements, and observations by the inspector.
Mr. Shopenn also reviewed the action you had taken with respect to two violations observed during.our previous inspection, which was conducted July 21 and 28, 1976.
He verified that the corrective actions with respect to these items were implemented as stated in your reply of August 13, 1976, to our letter dated July 30, 1976.
During this inspection certain of your activities were found not to be conducted in full compliance with NRC_ requirements.
Consequently, you are required to respond to this matter, in writing,.in accordance with the provisions of Section 2.201 of the NRC " Rules'of Practice," Part 2, Title 10, Code of Federal Regulations. Your response should be based on the specifics contained in the Notice of Violation attached. to thiseletter.
I The responses directed by this letter and accompanying Notice are not subject to the clea_rance procedures of the Office of Management and Budget.as required by the Paperwork Reduction Act of 1980,.PL 96-511.
T MRPS
, MRPS TPB DIES RA MShopenn/de JEverett GBrown EJohnson JCollins 4/29/82 4/ /82 4/ /82 4/ /82 4/ /82 READING FILE COPY N'
820s2eo iy 1
~
Western Company of North America Should you have any questions concerning this letter, we will be pleased to discuss them with you.
Sincerely, Glen D. Brown, Chief Technical Program Branch
Enclosure:
Appendix - Notice of Violation bec: c/o DMB (IE-07)
AE0D IE Files IE/RSB NMSS NRC PDR bcc: RIV J. Collins EJohnson/ Marshall Inspector S. File HQ File RIV File O