I H:rry Tsuber ab treswm i

Detroit Edison ETEre" i n 2;7 n "e2 Mr. B. J. Youngblood, Chief Licensing Branch No. 1 Division of Licensing U.

S. Nuclear Regulatory Commission Washington, D. C. 20555 4

Dear Mr. Youngblood:

References:

1.

Enrico Fermi Atomic Power Plant, Unit 2 NRC Docket No. 50-341 2.

Letter B. J. Youngblood to H. Tauber dated February 24, 1982

Subject:

Operability of Containment Purge Valves for Fermi 2 Responses for the three (3) items listed.in the referenced letter are provided in this memorandum.

These responses, along with our previous submittals, fully address the purge valve operability issue.

1.

A commitment to modify the valve and valve disc orientations is contained.in our letter of January 4, 1982 (EF2-55,980).

The valves are punchlisted as incorrectly installed, and the installation modifi-cation is in progress (SU-8258 and EF2-57,112).

2.

Table 3.6.3-1 of the Technical Specifications con-tains the inservice inspection information for these valves.

3 The valve will operate automatically even in the manual handwheel mode.

The handwheel clutch is disengaged when this occurs.

Should you have any questions, please call Mr. L. E.

Schuerman, (313) 649-7562.

Sincerely, 4M

[h cc:

L. L. Kintner B. Little i

-