t Fo/m NRC418 U.S. NUCLE AR REGULATORY COMMISSION

/

l CERTIFICATE OF COMPLIANCE g CFR 71 F r RMioactive Materials Pcckages 1.(:) Certificate Number 1.(b) Revision No.

1.f c) Package identification No.

1.(d) Pages No. 1.(e) Total No. Pages 9090 3

USA /9090/A 1

3

2. PRE AMBLE 2.tal This certificate is issued to satisfy Sections 173.393a.173.394,173.395, and 173.396 of the Departrnent of Transportation Hazardous Materials Regulations (49 CFR 170189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of Transportation Dangerous Cargoes Regu!ations (46 CFR 146-149), as amended.

2.(b)

The packaging and mntents described in item 5 below, meets the safety standards set forth in Subpart C of Title 10, Code of Federal Regulations, Part 71, ** Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions."

2.fc)

This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the government of any country through or into which the package will be transported.

3. This certificate is issued on the basis of a safety analysis report of the package design or application-3.(e)

Prepared by (Name and address):

3.(b)

Title and identification of report or application:

Allied Chemical Company Allied Chemical Corporation application Allied Corporation dated May 18, 1977, as supplemented.

P.O. Box 430 Metropolis, IL 62960

'i.(c)

Docket No. 71-9090

4. CONDITIONS This certificate is conditional upon the fulfilling of the requirements of Subpart D of 10 CFR 71, as applicable, and the conditions specified in item 5 below.
5. Description of Packaging and Authorized Contents, Model Number, Fossile Class, Other Cond.tions, and

References:

(a)

Packaging (1) Model Nos.: 48 OM, 48 H and 48 HX (2) Description Metal 48-inch UF cylinder.

Gross weight nominal 30,150 lbs.

6 (3) Drawing The 48 OM packaging is as described and constructed in accordance with Allied Chemical Corporation Drawing No. 515172, Revision B and Job Specification JSP-226, dated March 4,1966, revised January 24, 1967.

The 48 'H packaging is described and constructed in accordance with Union Carbide Corporation Drawing No. E-M-14864-A, Revision B, and Equipment Specification No. ES-CMD-14864-1, Revision 0, dated September 29, 1978. The 48 HX packaging is as described and constructed in accordance with Union Carbide Corporation Drawing No. E-M-14864-B, Revision 0, and Equipment Specification No. ES-CMD-14864-2, Revision 0, dated February 20, 1979.

(b) Content (1) Type and form of material l'ranium hexafluoride (UF ) in solid form which meets the requirements 6

as low specific activity material as defined in 10 CFR 571.4(g).

82 0 510 0 p (d

f' p

Page 2 - Certificate No. 9090 - Revision No. 3 - Docket No. 71-9"90 5.

(b) Content (continued)

(2) Maximum quantity of material per package Maximum U-235 enrichment, pounds UF, and U-235 content for the cylinder

~

6 model as follows:

Max. Enrichment w/o Max. UF Max. U-235 6

U-235 Pounds kas 1.0 27,030 82.9 6.

Valve protectors must be provided as described in ORO-651, Rev. 3.

7.

The fabrication (new packagings only), assembly (new packagings only), testing, maintenance, and use of packagings must be in accordance with the requirements of OR0-651, Rev. 3 except that design shell thickness is 5/16", minimum allowable shell thickness is 1/4", and the routine hydrostatic test is to be performed at 200 lb/sq in. Materials of construction for the 48 OM packaging are given in Job Specification JSP-226 and for the 48 H packaging in Equipment Specification No.

ES-CMD-14864-1, Revision No. 0 (alternate A285 steel not authorized).

8.

The Model No. 48 HX packaging must be transported only when a determination has been made by the shipper that the average daily temperature or ambient temperature during the shipment will not be less than 30*F and the temperature of the contents at the time of delivery to carrier for transport is at least 30*F.

9.

The package must be transported on a motor vehicle, railroad car, aircraft, inland water craft, or hold or deck of a seagoing vessel assigned for the sole use of the shipper.

10.

The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b).

11.

Expiration date: May 31, 1987 l

l l

l l

l

s g'

Page 3 - Certificate No. 9090 - Revision No. 3 - Docket No. 71-9090 REFERENCES Allied Chemical Corporation application dated May 18, 1977.

Uranium Hexafluoride Handling Procedures and Container Criteria, ORO-651, Rev. 3, August 1972.

Testing of Ten-Ton Uranium Hexafluoride Cylinders, KY-500,.0ctober 22, 1965.

Testing of Fourteen-Ton Uranium Hexafluoride Cylinders, KY-549, May 15,1968.

M"tional Reference Required for the Model No. 48 H Packaging Department of Energy supplement dated: January 5,1979.

Additional Reference Required for the Model No. 48 HX Packaging License Application for Type 48 HX Cylinder for Shipment of Natural Assay UF-6, KY-697, February 26, 1979.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION k&

--l Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety Date:

i I

i

yA U.S. Nuclear Regulatory Commissien Transportation Certification Branch Approval ~ Record Model Nos. 48 OM, 48 H, and 48 HX Docket No. 71-9a90 1

By application dated March 31, 1982, Allied Chemical Company requested renewal of Certificate of Compliance No. 9090.

No changes have been requested or made to the packages since approval of latest supplement dated February 26, 1979.

The staff concludes that the statements of the original application, as supplemented, satisfies the requirement for renewal of the Certificate of Compliance.

Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety, NMSS MAY 101982 Date:

t e