DlDA/RYLAND h
[k COOPERAT/W
- P.O box 817
- 2615 EAST AV SOUTH
- LA CROSSE. W1SCONSIN 54601 (608) 788 4 000 April 29,1982 In reply, please refer to LAC-8245 DOCKET NO. 50-409 Mr. James G. Keppler, Regional Director U. S. Nuclear Regulatory Commission Directorate of Regulatory Operations W
/ p/,h e
Region III x
799 Roosevelt Road p'
Yg Glen Ellyn, IL 60137 g
REcgWED
SUBJECT:
DAIRYLAND POWER COOPERATIVE t
MY10iS86 'lT LA CROSSE BOILING WATER REACTOR (LACBWR)
UWaw %
'p?~Jf 38 PROVISIONAL OPERATING LICENSE N0. DPR-45 c)
O 10 CFR 21 REPORT
REFERENCE:
(1) 10 CFR 21
Dear Mr. Keppler:
This letter constitutes the notification required by Reference 1 of a component supplied to the Lacrosse Boiling Water Reactor which contained a defect.
On April 26, 1982, ASCO Environmentally Qualified solenoid valve, catalog No.
206-380-2F, serial No. 48976J, was determined to have a defect. The coil retaining clip and fluxwasher (see attached sketch) were found loose inside the solenoid housing enclosure. With the retaining clip not installed, there is sufficient room for the coil to move vertically off the solenoid base sub-assembly approximately 1/4 inch, which could lead to coil overheating and eventually failure.
Examination of the retaining clip showed it was slightly misshapen. This solenoid valve was a spare and had not been installed in the plant.
All the ASCO EQ solenoid valves which had been installed prior to discovery of the defect were installed in locations where failure would have been in a safe mode.
All 39 ASCO Environmentally Qualified solenoid valves installed or to be installed in the plant were examined on April 27, 1982. Seventeen were of a different design and therefore not opened. Fourteen of the solenoid valves had retaining clips similar to the one discovered loose. All were properly shaped, but one clip was not fully in place. The solenoid containing this clip, 73-25-017, is one of two redundant solenoids which operate the inboard Containment Building Ventilation inlet damper. The ASCO solenoid was installed in the fall of 1980 and has operated without failure. The catalog number of this solenoid was NP831654. An electrician properly installed the clip, which was verified by the LACBWR Electrical Engineer.
h d h K 050004o9 17 820429 S
g 3 @2 PDR s ih ZE /9
o Mr. James G. Keppler, Regional Director April 29,1982 U. S.- Nuclear Regulatory Commission LAC-8245 Region III page 2 The remaining eight ASCO EQ solenoids had a nut and bolt arrangement instead of a retaining clip. The catalog numbers of these solenoids are 206-380-4U, 206-380-4RU, 206-380-5F and NP831664E.
Mr. Robert Brimer, LACBWR Electrical Engineer, informed Bob Klick, Simone Engineering, the solenoid vendor, and Dick Beverly of ASCO on April 26, 1982. The spare solenoid valve is being returned to ASCO for examination.
Initial notification to the Nuclear Regulatory Commission was made to Paul Byron, NRC Region III, on March 28, 1982, by L. Goodman, LACBWR Operations Engineer.
If there are any questions, please contact us.
Yours very truly, DAIRYLAND POWER COOPERATIVE 44 James W. Taylor Assistant General Manager-Power JWT:LSG:dh Attachment cc - Director, Office of Inspection and Enforcement (3)
U. S. Nuclear Regulatory Commission Washington, D. C.
20555 Document Control Desk U. S. Nuclear Regulatory Commission Washington, D. C.
20555 NRC Resident Inspector i
m 7
l
~
CDvf 88 *'t w ScaE *0 0t AND
%j;!
..'7 O O
% Awt PL Af t A f f ACHf D.
's
/
M **
PAnf56NCLUDfDIN COVE R CASKE T$
SPARF PART3 Kaf $$
I#
RET AINING CLIP h IMPORTANT F LUKW A$NE R D
IAO PARIS A$
THEY ARE REMOvt0 ]
YOKE q
-$LEEVE
~
N
INSULATING wA$NE R FCR SOLENotD 8 ASE N
O (OMITTED wHEN MOLDED
$US ASSEMSLY l
}
(
COf L is USEDI s
(DRDER NO. 206 40m SOLENotD 8 ASE SUB. ASSEMSLY $
k
(*N-
\\
- NSULAT6NG w ASME R (OutTTED WHEN MOLD (D 1/2 NPS OR 3/4 NPT CosL 15 USEDI CONDUlf CONN ECTION MOUSING s
SLEEVE RE TAINE R C ASE E T
(
UPPER $PRING.$
r CORE / SPRING (STRONG l
$US. ASSEMBLY qj UPPER VALVE OfSC$
$0L M Ds m W E
()
LPPE R VALVE SEAT $
8 INSE RT CORE /5PRING DE GuDE W GASEET $
$US. ASSEMBLY THRU UPPER SOOY OPENING.
-g VALVESODY ENGAGE IN END OF PtN SEARING GASEET$
VALVE LEVER.
)
~
PIN SE ARING $ CREW Q
OtSC GUIDE CAP GASEET$
essescema t m essee
"'*A*"..e.
pg LOWER VALVE $ EAT $
BeOuNnNG l
BAACKET LOWER VALVE DtSC$
I E-C- G=u*
u,WER -,,sG,
VALVE LEVER y,
y E -
M
-ernes TNIE VIEW SHOW5 VALVES telTN 3/16 AND 1/4 ORIFICES.
FOR VALYes WITN Efte OelPICES OA STE EL OR STAINLESS m ssee STEEL CDNETRUCDON.THE EXTERNAL 900Y AND INTE ANAL PAATS CONFIGURATION AAE SLIGHTLY DIFFERENT.
areas ess_aa a.mmassesove v-
_q_=_
s - a - ere eees.e weesseshe asemesed Essessese She==.
For W/weasuges Seas ead Eastase e Ptosse 3.
Used on amanese 3es4st med 3004M. See Farms No. v.83el.
@ AltkWRITilf.'411Ch CfL..====.
_