Notice of Violation from Insp on 820412-26
ML20052E678
Person / Time
Site: Limerick  Constellation icon.png
Issue date: 04/26/1982
From: Starostecki R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML20052E675 List:
References
50-352-82-07, 50-352-82-7, 50-353-82-05, 50-353-82-5, NUDOCS 8205110336
Download: ML20052E678 (1)


Text

'

4 APPENDIX A NOTICE OF VIOLATION Philadelphia Electric Company Docket / License:

50-352/CPPR-106 Limerick Generating Station, Unit 1 50-353/CPPR-107 From April 12 - 26, 1982, the following violation was identified under the NRC Enforcement Policy,10CFR2 Appendix C (47FR9987, March 9,1982).

10CFR50 Appendix B Criterion V requires that activities affecting quality be carried out in accordance with instructions and procedures. General Electric Specification 22A2724. Revision 3 Paragraph 4 and Thble I Paragraph 5 require that components such as reactor protection instrumentation receive pericdic inspection for conditions such as protective covers, seals, and damege; and that controls and instrumentation be protected from dust, dirt, damage, and humidity.

Contrary to the above, the turbine stop and control valve scram bypass pressure transmitters PT-01-1N052 A through D were not inspected and protected as required:

they were deleted from the storage and maintenance program on April 24, 1981 after being partially installed, and their covers and seals were not intact on April 13, 1982.

This is a Severity Level IV Violation (Supplement II).

i Pursuant to 10CFR2.201, Philadelphia Electric Company is hereby reqdired to submit to this office within 30 days of the date of this Notice, a written reply l

including (1) the corrective steps taken and results achieved, (2) corrective steps to be taken to avoid further violations, and (3) the date when full compliance will be achieved. Under the authority of Section 182 of the Atomic Energy Act of 1954, as amdnded, that reply shall be submitted under oath or affimation. Where good cause is shown, consideration will be given to extending the response time.

OMA gg Dated 20 E

[ abo t Richard W. Staroste 1 rector Division of Projec n

esident Programs 8205110336 820426 PDR ADOCK 05000352 O

PDR l