_.

G U-0473

/LLIN0/S POWER 00MPANY

.f y t39_g2(o4_39y_s 500 SOUTH 27TH STREET. DECATUR, ILLINOIS 62525 April 30, 1982

\\ 9' ' '$

3

'C-e p 4l,h-QS Mr. James R. Miller, Chief

{

6

^

Standardization & Special Proj ects Branch 8p%

g Division of Licensing N

Office of Nuclear Reactor Regulation g

U. S. Nuclear Regulatory Commission

'qj' Washington, D.C.

20555

Dear Mr. Miller:

Clinton Power Station Unit 1 Docket No. 50-461 With reference to CPS SER Confirmatory Issue #8, "NSSS Pipe Break Analysis Using SRP Criteria (3.6.2)",

General Electric Company has reanalyzed the piping in question using the 2.4Sm criteria as specified in the SRP.

The analyses revealed that there were no more breaks using the 2.4Sm than there had been using 3.0Sm.

Therefore, we consider this matter closed for licensing purposes.

t Sincerely, E

~

G. E. Wuller Supervisor-Licensing Nuclear Station Engineering r

CCW/lt cc:

J. H. Williams, NRC Clinton Proj ect Manager H. H. Livermore, NRC Resident Inspector O001 D. Terao, Mechanical Engineering Branch 9

Illinois Dept. of Nuclear Safety

)0 1

l i

l i'

i 8205070197 820430 PDR ADOCK 05000461 E

PDR

[

i-