ML20052C801

From kanterella
Jump to navigation Jump to search
Trip Rept of 820225-26 Site Visit Re Human Factors & Plant Operations.Studies of Formats for Control Room Display Console & of Human Factors Problems Re QC Aspects Recommended
ML20052C801
Person / Time
Site: Clinton  
Issue date: 03/03/1982
From: Debons A
Advisory Committee on Reactor Safeguards
To: Savio R
Advisory Committee on Reactor Safeguards
References
ACRS-CT-1426, NUDOCS 8205050557
Download: ML20052C801 (3)


Text

k,.Y/2lrp SCHOOL OF USRARY ANo INFORMATION SCIENCE 6 Departme-t of Irvformation Sesence f*

TO:

Mr. Richard Savio NRC n

s e

< c, h

/

FROM:

Anthony Debons, Ph..

,-/

?'

) ue*.'ln 91982r Q Consultant DATE:

March 3, 1982 g Lt,.,c3.g ;

,s s..y s

8 Technical Review of Clinten Plant Visit 4 Decanteur, Illinois, February 25-26,1982kgg

SUBJECT:

1.0 General Assessment Visit did not allow for the detailed study of the many aspects of human factors that could be applied to total plant operations' (including training, career development, habitat, etc.). To best of available knowledge there is r.o Human Factors representation at the staff level of the plant organization.

Human Factors is accountcd ~through services of a Human Factors consultant. There is a need for'a well formulated research program for the test and validation The of present display fomats developed by the applicant.

Remote Control " shut down" Display Panel requires careful study both in tems of console configuration and location.

Training program needs careful examination of underlying career assumptions.

2.0 Human Factors Representation The magnitude and importance of human involvement with technology and plant procedures suggest that human factor (ergonomic) principles can be extended to the following areas:

2.1 Main control room display design and operations.

This includes the Remote " shut down" Control Display Console.

2.2 Quality control in the present construction program and subsequent maintenance requirements.

8205050557 820303 PDR ACRS CT-1426 PDR PITTSSUROH. PA.15200 (412) 824-5208

r-4 Mr. Richard Savio March 3,1982 Page 2 2.3 To the environmental conditions projected for operational status. This includes such factor: as general habitat, lighting-heating conditions under prolonged work

. schedules, noise, vibrations, etc.

2.4 Training.

The impact of career ladder structure on motivation and ultimately on productivity. These considerations need to be carefully. integrated into the present' policies for training of personnel, if not presently included.

3.0 Control Display Console The applicant is proud of present display fonnats included in the Control Display Console. The display fonaats, however, appear crowded.

At present it is not possible to correlate the effectiveness of display formats with human perfonnance requirements.

The Remote " shut down" Control Display Console seems primitive.

It leaves the impression that.it was included as an after thought in the design of the overall plant configuration.

~

Variations in electric source output can severely influence the resolution of data on displays particularly those which require high levels of visual acuity.

On the other hand information presented by the app 1tcant suggest that this factor has been acknowledged.

4.0 Quality Control Numerous incidences reflecting inadequate quality control in the construction activities were reported.

Quality control practices by the contractor were defended.

Specific instances of good quality control were cited in contrast to the many other quality control violations.

In most of these cited instances there was a recognition of symptoms rather than causes.

In aome instances of inadequate quality control cited in tne literature, failure in quality control can be traced to poor acknowledgment of human factors parameters (i.e. poor lighting, poor work habits, fatigue, motivation, etc.).


__------------,_s

,w,,,,

,---,,,,w m--

~,-,e,-my w--,-,-,,

-f bc 8h Page 3 5.0 Environmental Conditions Plant configuration and mission suggest that operational personnel will be shielded during work hours from the environment outside of the plant.

Further, it is reasonable to speculate that the nature of the work environment can promote possible states of uncertainty and stress. These

~

conditions can lead to a sense of isolation and at times, depression - the extent of which should be identified and studied.

Other factors include the influence of prolonged noise, heat and other ambient conditions which could seriously impact on human performance (e.g. tracking, vigilance, etc.).

6.0 Training The training program seems well formulated.

Liaison with local educational institutions has been established.

Career ladders - for progressive career development and training -

are available.

The following aspects underlying the training program however need to be examined.

6.1 The' requirement for college level achievement to meet specific work levels.

6.2 Retraining concepts based on technological state-of-the-art developments.

6.3 Criteria for validating training effectiveness.

6.4 Inclusion of Human Factors study in current college level curriculum.

7.0 Recomendations 7.1 Develop a specifically defined and well delineated research program for the study of display formats for the Control Room Display Console.

7.2 A study should be initiated on Human Factors problems related directly to quality control aspects. The findings of this study should clearly suggest a program for the generating of policies which insure that Human Factors are sufficiently acknowledged in instances of quality control ncn-compliance and breakdown.

-y

,. -,.,.c-e

~,.

,e---

-