Text

,

o-LOUISIANA f,42 octAnoNoe srneer P O W E R, & L I G H T/ P O BOX 6008

  • NEW CRLEANS. LOUISIANA 70174 * (504) 366-2345

'iiEONsysN E

u February 16, 1982 W3K-82-0092 Q-3-T33 Mr. John T. Collins, Regional Administrator, Region IV U. S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 1000

'/[{$~

Arlington, Texas 76012

.g Mr. John Woodward h g g g '{ 'i Factory Mutual Engineering 12 Perimeter Center East, Northwest is'2.(

I Suite 1200 "V

Atlanta, GA 30346

/

f' b --

_j j;

j

/ '} (

r,

(

Mr. J. W. Morvant j'

Q'-

~

Louisiana Department of Labor P. O. Box 44063

\\

}

Baton Rouge, LA 70804

\\

. v

Subject:

Waterford SES Unit #3

/

Repair Program for the Steam e

att e Plugging Re:

Docket No. 50-382 Gentlemen:

Enclosed is the repair program for the Waterford SES Unit #3 Steam Gen-erator tube plugging. This program has been reviewed by Louisiana Power &

Light Company in conjunction with Ebasco Services, Inc. and found acceptable.

This repair program is submitted for your review as required in paragraph IWA4130 of the ASME Section XI Code.

If there are any questions regarding this ongoing act!vity, please advise.

Very truly yours, h

Af

-Q %l l% ? D T. F. Gerrets Quality Assurance Manager TFG: RAH:grf cc:

L. L. Bass, W. M. Morgan, J. Woods, L. A. S tinson, L. V. Maurin, D. B. Lester, R. K. Stampley, R. Hartnett, P. V. Prasankumar, F. J. Drummond, Central Records, Nuclear Records 8205030 W

'/

.