Text
_
'?!- 9/G o O
cc e
/
/d RECENED {'
E APR 5 1982
- t" v.s.ng"**'" @j, HMSS y
mass **'
Cu GULF NUCLEAR, INC.
PACKAGE EVALUATION MODEL 20-VS MODEL 40-VS TYPE B QUANTITIES C
g D774, Y 'J " h poKma 9
us s Applicant..........
.1 M>
chacucAIN.l..
s APR 161982 > d Q.'.ll,!
Z i.nu n /f;a I
NM l'jdeQIEC3.
,gg g
DEO Ch*I;k !
//.
9 00CKET CLERK Received By c
g
.c.
2 02 MEDICAL CENTER BOULEVARD WEBSTER, TEXAS 77598 PHONE:
(713) 332-3581 O
anzas 820429o/JG
O CONTENTS Page 1
General Information 1
1.1 Introduction 1
2 Package Description 1
2.1 Packaging 1
2.2 Contents of Package 1
3 Structrual Evaluation 1
3.1 Discussion 1
N 2
3.2 Design Criteria 3.3 Wei,ht 2
3.4 Mechanical Properties of Materials 2
3.5 Chemical.and Galvanic Reactions 2
3.6 Positive Closure 2
3.7 Lifting Devices 2
3.8 Tiedown Device 2
4 Ilypothetical Accident Conditions 2
(}
2 4.1 Free Drop 4.2 Puncture 3
4.3 Thermal 3
APPENDIX 1
Drawing of 20VS and 40VS 4
2 Pictures of Free Drop Test
~5-7 3
Pictures of Puncture Test 8
j l
4 Pictures of Thermal Test 9-10 5
Radiation Profile 11 6
Approval Letter for RG-13 and RGSA-13 12 13 7
Witness
' (:)
.- =-
O 1
GENERAL INFORMATION The enclosed information concerns a metal container which weighs thirty-eight pounds and contains thirty-four pounds of depleted uranium.
The container is a radiography device used to perform field operations and is used to transport Iridium-192 sealed reorces.
1.1 INTRODUCTION
The containers, Gulf Nuclear, Inc. models 20-VS and 40-VS will be used to transport 100.0 curie and 200 curie Iridium-192 sealed sources.
The container is approximately six inches wide, eight inches long and twelve inches high.
The upper portion includes a handle for carrying purposes.
The outer case and all external parts of the container are fabri-cated from stainless steel.
The two containers, Model 20-VS and 40-VS, are identical in construction.
The two model numbers reficct a slight difference in the internal shield.
+
2 PACKAGE DESCRIPTION 2.1 Packaging The package contains a depleted uranium shield which is designed to shield a 100 or a 200 curie Iridium-192 sealed source.
The sources, Gulf Nucicar, Inc. Model RC-13 and RGSA-13, meet special form requirements (See Appendix 6).
The shield is contained in a stainless steel case.
The void between the shield and the case is filled with epoxy ( See Appendix 1).
2.2 Contents of Package The container is used to transport quantities up to 200 euries of Iridium-192.
The radioactive material is contained in a scaled source configuration that meets special form require-ments (See Appendix 6).
3 STRUCTURAL EVALUATION 3.1 Discussion The outer shell of the container is constructed of stainless steel which is.076 inches thick.
With the exception of the top lid, all seams are welded.
The lock block, nose piece, etc. are either stainless steel or plated steel.
The epoxy filler adds strength to the assembly as well as being a fire shield for the depicted uranium.
{}
(1)
(2)
()
3.2 Design Criteria The package is designed to function as a radiography device as well as a transport container.
Radiation considerations are such that the package has a radiation level of less than 200 mR/hr on the surface and less than 50 mR/hr at six inches.
The package is also designed to meet Yellow III label criteria.
3.3 ueight The weight of the package is forty-two pounds.
3.4 Mechanical Properties of Materials All metal parts are fabricated from steel with the exception of the shiciding material which is depicted uranium.
The internal space between the shield and the housing is filled with epoxy.
3.5 Chemical and Galvanic Reactions The radioactive materials are contained in a capsule con-structed from 17-4 Pil stainless steel and meets special form requirements.
There is no chemical or galvanic reactions between depleted uranium, epoxy and steel.
O 3.6 Positive Closure The radioactive source is held in place with a lock, a safety plug in front of the source which is a snaptite fitting and a dust cover in the lock block that fixes the back of the source.
3.7 Lifting Devices There is a handle on top of the container that is designed for lifting.
3.7 Tiedown Device There are no tiedown devices that compromise or add to the integrity of the container.
4 11YPOTIIETICAL ACCIDENT CONDITIONS 4.1 Free Drop The package was dropped thirty feet onto a k inch steci plate placed on an eight inch thick concrete pad.
Some physical damage occured but shiciding and container charac-teristics were not compromised (See Appendix 2).
~
(3)
()
4.2 Puncture The container was dropped forty inches, striking a six inch diameter bar, eight inches long.
i l
4.3 Thermal i
The container was suspended over a six foot diameter tank-containing diesel fuel.
The fuel was ignited and the fire i
maintained for thirty minutes.
Temperature was monitored to insure that a 1476 degree Fahrenheit was reached.
t Results:
The container had no visible damage.
Flammable gases were emitted during the test and for three minutes i
after the fire was extinguished.
There was no apparent damage to the shield (See Appendix 4).
The radiation
]
profile measured after the test is presented in Appendix 5.
The device was still functional after the tes: series were completed.
4 4
I i
i l
i t-
APPENDIX 1 JAWw ANNNNNNNN NNNNN NNNNNNNNNNWXS:
_w__._
$~~'A~
MMxNNNNNNNNNNNNNNNNNNNNNMM%
L e xxxx uxxxxxxxux u s u u um A
'('
Ds g.
3.g_h[39h'i
3} k'4g y p y
-- ~
.~.:.
~
~-
Y..psg-[_.
(
Ql#8..h7
')
x s
ec i
l zs C5
?'s i
q.M g' 's i!
s
' N, j'
s fk' K.
h k'h.
k,s M i
% %.}$
m s
.MN
- +
9 t.
x s.
q s >g
.h's.
g.
^
M%,,Ng,t s
N N
s
>q".. " ', xx3: y s. &c:
'. p,2.%
j i
s s
N 6
a
/
x g> s.
.s' 5 :,
.Sp
,(
N: ',
- f. 'syy., s.;
s Ol2 e
g's.;;.u qs '. x'p,'$,c.
' n, y a
w.
~-
ys, a u' ' "r--
4 [,
.t
,wa p
j:\\'
d]_(7. i/
- g i gg W V,
( -
4-s g(';;
s' [} ;. ' '
, ' 3 QN '4#dh> x =
~, -
o s f
. se.
s
~
~
~
s s
a ',
i i
p l
1 B * * =* " "~Tr==* N =u--
~
SEAM WELD BEVISIONS l
NOTE: WELD I5 GULF NUCLEAR,INC.
t O.
Dart x
CONTINUOUS 3
FROM A TO B 20-V C A MERA g
2 3
)RAhN BYMPA SCALE MATERIAL DATEl 21-82 DRAWING NO.
4 2HK'D APP'D B - 12 5
- ' RACED (4)
4,12 5" -- --
~n
~r
\\ ~.
N.
w
\\
ZlRCALOY
' n[')hl b[g-O!< 'f lTANIUtd T
-- T U E IN G
~
e,e
.5101 0.0.
e qi
/
'74030 Wall.S ey
'N F
\\
/
/
Iw J
j N
l.62$_-
)
I l
/
- - ~
_J.25( ~ _
2 0"
,/
3.750" g
l
\\
.l25 R. T Y P
\\
a
.i 6.500
-(~
i
'N
/
\\
i J
I
--- -1.CCO i
x
[
I
)
\\
t N,
_T REVISIONS GULF NUCLEAR,INC.
i> Arm sy
)
20-V URAN IUM CAST ING 2
g 3
)RAWN BvM P A SCALE FU L L MATERIAL DATE -29E 2 DRAWING NO.
l 4
2HK'D APP'D 5
2 RACED
FRONT vi:_w
-.125 R. TYR O
</
i c
II,
kl
.250 R. TYR
! (%},
-HDT TOP l
w i N
f 1
/
,\\
\\
i i
i e
a e
3 G503 3.750, n
[
15 d ' r-l-- )!
- ~
/
9 l
l 3750; g>
l O
j
./
l l
l f.
l L
r i.
i
r_
l l
_. _L s
t
,- _ i,, - -
FEVISIONS 10.
DATE
_BY 1
-- - _20-V URANIUM
. CAST.ING 0
2 3
anAwn syMPA SCALE FULL MATERIAL DATE2-12-82 DRAWING NO.
4 2HK'D f
APP'D 5
- ' RACED
l
~
APPENDIX 2 FREE DROP TEST
- J.
1
- .. - a ;.., - -
~
['
hh*.
N J5 -
lij g s.
~
i e ' ** '
j-tA.
's.
4
- g*
f
Q&.g.%.
l r,
e t>
y Q
- n 4.,
fp+..:
S.
n,
.Q w n.,
g 7 -~ -
. \\h..,.
- {'*
J,, '
,1. 7e i ;#..
N"
,l
~
.m6 4
'q..e-fgs,h
'4 g.-
y i
- -Y.
h,.;g.5 -
s h
., g g, ],.
.g s;,,,
.-5 y y.,-
Device before the test 1
i 7....
y~
_.; ~.,.
w
~
V^
7 t
k
.; en g,
..=.. -
- a.
~
g m
e~
m 4.
w
- 3 - -
e p [o.,
.b ' j 9g ' #
L'
..] :,.I
.}
t.
.i -
- ja.
a
, ; %.t.'..
l 9,-
,-.g....
4 r..
'*p
' ~'
- 5p m'
. r..
A w a s,1
.*... em g
. 6 n
l lg, %:.xu -.d,sl.Q$Q,;: g;c.m,
- e.
r'*9
=.,:
.c i
t,3
- g.
u a
^
g,..
-L m.f Q.',j'Y, _
- ' * ; 1.g,
. y.@Q, N,
N
," g 4
',.,i.[
$1[y;;-l, N
, ; % g. :, Q. '..
5 3
,f' I
- ~.i ' 'E f
'k
' ~
- b J Y
i l
- :. -. ; 3..
w 1
,.., 7 5 m.,n s
'f Ar 1 9
'Y&s O. @.g?. -
l
' '5 1
7.
- w 6:..,><
' ',Y '.,,
f._.
}y' 52
- _p
. srq -
- (KQp y
k.y : J
_~ sa'
' %??"-
I
.35,_
. ',. L Device being prepared for drop f
(5)
l l
l APPENDIX 2 (Con't)
FREE DROP TEST f
I
~ ~. -
'......::.....,..... v, A
- n.f.
" - --I'
., 9,
,94
,r
.^
f} >.:.,. k,.
t
'l-,
- .. \\ '..1*w.>i
- .?
t.
l-
%6
,l.Q ' Kf
%Q-W Tlw y [ - g:.; _ _
~
s ~ h.' 'y
~-:
... [
.v t awag,,..e.ev.,w v g
.,. y y;g, M,
I
,+
z_.
-s
.: a!n
~ m
-t w t.
. 9.,,
.i g
.N....J
~.M s
c-
,7
.- p sy e
~, 7,..
?
" 4
. - g..
,,. s -
g~^
' ~ -
.e s.
4.
p
'.=.%...g
-?.$tW-.
c1 >,.
e
- p. y 5
.........'a
' <r 3
d Y.,...'..,.,o. T,. [. '._
"y I
p"
- E an.
s<.
Device striking pad
(
)
1
. - f.
- ^
- 4, G
_,l e
['
'... fi'
,l
'Q:.
, %d".
l s
7-l
),
t
}
- 4y -
^
1.
s.-
.h g
+
,, e s'
.t
- %g...g % -: ;, -
~
7.~
- ra p',
t
$,*# '[
'g*
.~~
M _";,/ f 4. ft,f,.4:j$
. g 'i. ' i ;. > t.g s
A. p: w.
. y.'
+
+- ^'.
l g.: z w..
mae ~.,
.m, w.
~
/
... R.-
f ' {*.n.k i -J.' -K Q-;W, -
Vl, h;. 5,...
3,;
, e
.. sa g.
1
- s. -
lG.
.y y - #_
x
._L.
4
,f i)O 44'::.-Q l;7 ' Q, > *,.
. y
.i
~.
,g y.:1.. -.
8;
- v. ;... x.-
3, ;, ;L f ? W l.w-Q s g.-y- [ r~;. '# 9. - -
[9 Device after striking pad (6)
i I
l APPENDIX 2 (Con't)
FREE DROP TEST
-w s@&
4 1
5* c,
j m
f
^
.j I.
.'C
- k.v~
j e
W'.
4
, 1,.
~
4:t h
- ~C
' M.
,t g.,
~~
- f." -
>&. ~
l h
., ~
g "t
F.,'.
- s.
e-l l
Device after striking pad
'^
I:
h I
L l
V (7)
APPENDIX 3 PUNCTURE TEST
~
\\
. q. p.
.. q -
4 s
. 7 g'
.5
-'c j
., 4
- ^ 1.1...S
' tt Y.
.p.
\\
,3 pk~
l-l e. J p N'
2, m-
'g p.
.g' E
j ll i.
g g p' y--
'y m
l
\\.
. [
s w,,
L-~,.
\\ < < f^ f.
4
-t-s w
?
i s,...
7,..
' '..e
, [-.
..e c
?.
4 3,
- . g
..i.
t
- 1 -.
' $. ~
%[-w=w p Mw.;fQ
.N g
Q
- . [s
.} _.
l 9
Device striking pin
?
J.
.,,. =. _.
z l
-? ~-
>~
f_.n;'
g?
C ' ~
' N. ' =
' ~
,..j g
q..
i, A,s $~'.$
a..-
s.
.1.-
l, s
i g.
l
...Yn:
f '*,.:
,, ~
S
^
.J5
t '-NC ( G ', ' Mg-y ' ; p ',',,.'
E e_ sy g-v
~
,y.
- ~..
- .s
.c
- \\..
y l
~.:n
^
.A ' ' :
.4 4
- s
.c
.,," ^ ;..
- i..
E~ _
' i'*
s y
e Device after striking pin l
(8)
i APPENDIX 4 THERMAL TEST
~}
"W
-7
- b <,
f, a
1 f -'
- . m y-e. *J d
f ' w. (/.
j
~
~
[
?1lt.
K
)
i
..,t [-
i
[*'
,. g y,'..
) (, s '
q g.
l,-
- 7..,
d;, '.
edin' I*
k - tt' f
d p
-F
'4-:
I
(
j
}
K
% [+--
-- ~- "
L
}
2"'.g
.6T.'.,
~.
fe-
- .... 3.
L
?
.s.
i
~
.y
.. =
- 3,...._..e s.
.s,
.j
,l y7 wn f -
P Q.
i:.
_* ~ 7
=
k l
'.. }; ;;
{f.
f '.
I. N \\ '
- p'
.~' __
'f.~',
'. Q i.
l.
Y h
- >1 r
(( i.tfhYk.hh
, '. '- ~ q i
b,?.?i$stYk55 fYW
.'. v \\? 7 p
g ; g y 4 ypp k. :?
?
k l
< a;y.::
\\
Device before test O
- .....g.
-9 1
.. eg,p I
'.- ),~ _
- l*.
g-w., '...
+
w, _.,
t4 -
- s
=g 7-Q ' Q ' -
j
^
'. _' _ _,q e,
. id.
w :
.ig..-
.hl.
~
.A
-y
, g 4
. +
...r
": y;
+
- j
/
^
~, '. - *
+.
... &.. :
- g; '
g.
,s.
~ ~,,.
~
a....
w'
- s,. *,
a.
4
) h ','
~
}-_;_-
p 3 _
M*
i A
~ *:.f, jfy K, : -_ _.F.
- \\.', 4
.l.
1' Dev ic e during test (9)
APPENDIX 4 (Con't)
THERMAL TEST l
4 ;.,;. -
a., 's tt,'
....i b ~....
u.y
.n
- z a - n. s n
.a.
u m
~
s.,
r
. ' * ' ' * '6-'
' ' V
,yg_
_ f-_'
'4
...h,
~. -
y
'.'y,. 7,7z
.,.,f g.-
g m
m,y, u
..,, ~
y
. '. ('].
- g p' ;(
- .-
'y
-4 4'$'
j',(
- g 4.
- [.yf+f y l
.l
~ ~ y.
_ q
.$.T*
l 3.
S:
t....
~ ~ f.
.j f',-
r, -
p,;.
g-p f'y,q.-...
~
l
.F..
A., %gl% g.
1 d.s G
).
- F
~ ;;
g-
.+4eg
- t
'A
',,, a
~
y,=f g,
,=f.
1 -
.4 f.
- e
.q
. %.'+
n
+
.n-
-..; -.A
.b
, + ' 4 r..
.m.
9.y. <
s
.J
_ y * [,,. 4 -
y
,/
1, -
y..
l '
[o" g.
'.1
.P
-;,' A
, g
,{.
y2 N.
+
- 'lg;., f F t,..
y J
....'.s
~,_ M t~.-*
L :* '.,..,;..
y
.,4.
s.
..=.
+ -
.....,r-
- r y.,...
' N w, t.
.4 m-Device immediately after test I
h
. ;,..g.'
- , r e
- f.
. f.....,._,,
J, ',, ^
lg
% ~ y y} ? '.
_ -.m'.W.
- gf.3.". - c..
3
-u
.~
.s
..z)
"?
l i' s
.+
j
[
t.
+k
-lj
('
g,.
- I.
g f..Q. 41 4 -g,, f)-
'{' -
77 g:I
.s ',
f.m. : C npf s ;,.
c.,
' 4 s-s 4
L
[
.-r
.'m
.3
- ?$
w
.r.
y.
c
,A y.
y-
- R.'
.+
1 s
, \\...e. ~ A.-
=
Q, ', * :..
. '.f
..- -.. - + * -
m-f,.
- .%. 1 '. k p
3-
- t ',e e
,- f a
g:w s
7.
g q i s] ;
... ~,,
". *~j
-y,.
- .~ %..
4,
- A1g% m.L.
1'
-. : u..' : ;%... M. *h.., #) * '..
'~3
- l. '.n,,
W%..~.../
..~
..r.
...... - '.....',f,
?*_
~,
',.'?
',,.W(-_._-_
a:.
1 Device three minutes after test (10) 1
.............t 68' frca
~~~
All rczndingr.aur$kcn c t
.s c e,
APPENDIX 5
( )
B C
o d,
4
@~
4 E
f "N j
\\s' Serial Number Date 1/6/82 Model Number 20VS
~~gnature Si Jos.
Reading Notes (Prototype Stainless Steel)
_A 105 curies, Iridium-192 source in the survey Ebe'rline E-120G, S/N-5629, calibration date 11/17/81 R
lii g ifva i.
uiface reading 2 00-mR / h r c.-t-pos-i-t-ic n C
_C
-D E.
P 1G N
y.
I
.. J K
l (11)
g.
\\.
DEPARTMENT OF TRANSPORTATION RESE ARCH AND SPECI At. PROGR AMS ADMINISTRATIOff w ASHstJGTON. D C.
20M" IAEA CERTIFICA'E OF CCIMFD7T AUIHORITY Special Ibrm Radioactive :bterial Encapsulation Certificate Number' USA /0121/S (Fevision 1)
'Ihis certifies that the encapsulated sources, as described, when loadcd with the authorized radioacti~ve contents, have been denonstrated to neet the regulatory requimnents for special form radioactive material as prescribed in IAEA 1/ and USA 2_/ regulatims for the transport of radioactive materials.
I.
Source Description - Tne sources described by this certificate are identified as Gulf itsclear Inc., !bdels RA-17; RB-1, -2, -3,
-4,
-5, -6; RO-16; RG-13; FGSA-13; RS-12; RR-7, -9, -10, -11; RS-18; RP-14, -15; RPIi-4C, '-lG, -2NA, -5, -3T; and RAG-17, which are encapsulated in stainless steel and neasure 0.240" in dianeter and 0.400" in length.
Radioactive Contents
'Ihe authorized radioactive contents of these sources II.
consist of not nore than 200 Curies of Iridium-192 as netal pellets.
III. 'Ihis certificate, unless reneux1, expires Fty 31, 1983.
() 'Ihis certificate is issued in accordance with ihrginal C-6.1 of the IAEA Regulations 1/, and in response to the Ihy 6,1980 petition by Gulf Nuclear, Inc., Houston,
%xas and in consideration of the associated information therein.
Certified by:
IM8/ fed v V (Datc)
Richani R. Rawl 011ef, Radioactive lhteraals Branch Office of Hazardous lhterials Regulation Fhterials Transportation Dureau 1/ " Safety Series No. 6, Regulations for the Safe Transport of Radioactive Materials, 1967 niition", Published by the International Atcnic Energy (IAEA) Vienna, Austria.
2_/ Title 49, Ocde of Federal Begulations, Part 170-178, USA, Bevision 1 issued to extend expiration date.
p V
l
j~
4 j
APPENDIX 7 10
~
t i
i The hypothetical accidents,' free drop test, puncture test and thermal test, were witnessed by the following individuals.
I bl0A d-. h C.P. Hop'crMft, V/ce-President, j
i Production fd i
Elick H.
acree, Vice-President i
Research and Development j
i l
1 i
4 si iO t
i i
i P
e i
2 i
i
}
f i
i 10 i
t 205 2 4
(12) 3 4
..--___-.__.-_~_-..___..._..-._,___.+_,.,_.,...m.
- -. ~ - -. _... _,..,
_,_.....~.
~m.,-, ~. _,..
,.