ML20052A990

From kanterella
Jump to navigation Jump to search
Certificate of Compliance 9085,Revision 2,for Model Sentinel 8S
ML20052A990
Person / Time
Site: 07109085
Issue date: 04/13/1982
From: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To:
Shared Package
ML20052A987 List:
References
NUDOCS 8204290522
Download: ML20052A990 (3)


Text

F[m NRC418 U.S. NUCLEAR REGULATORY CoMMISSloN II CERTIFICATE OF COMPLIANCE i

10 CFR 71 fir Radioactive Materials Packages 1.(:) Certificate Number 1.(b) Revision No.

1.(c) Package identification No.

1.(d) Pages No. 1.(e) Total No. Pages 9085 2

USA /9085/Bf 1 1

?

2. PRE AMBLE 2.(a)

This certificate is issued to satisfy Sections 173.393a,173.394,173.395, and 173.396 of the Deportrnent of Transcortation Hazardous Materials Regulations (49 CFR 170-189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of Transportation Dangerous Cargoes Regulations (46 CFR 146-149), as amended.

2.(b)

The packaging and mntents descritx.d in item 5 below, meets the safety standards set forth in Subpert C of Title 10, Code of Federal Regulations, Part 71, ** Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions.**

2.(c)

This artificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the gotirnment of any muntry through or into which the package will be transported.

3. This certificate is issued on the basis of a safety analysis report of the package design or application-3.(a)

Prepared by (Name and address):

3.(b)

Title and identification of report or application:

Teledyne Energy Systems Teledyne Energy Systems application 110 West Timonium Road dated March 3,1977, as supplemented.

Timonium, MD 21093 3.(e)

Docket No. 71-9085

4. CONDITIONS This certificate is conditional upon the fulfilling of the requirements of Subpart D of 10 CFR 71, as applicable, and the conditions specified in item 5 below.
5. Description of Packaging and Authorized Contents Model Number, Fissile Class, Other Conditions, and

References:

(a)

Packaging (1) Model No.:

SENTINEL 8S (2) Description The packaging contains a thermoelectric generator with 55,000 Ci of strontium 90 titanate or strontium 90 fluoride.

The dimensions are 32.2 inches in height by 37.53 inches in diameter. The package is welded to a 39.5-inch square, stee's pallet, which is 4 inches high.

The contents are housed in a stainless steel or Hastelloy C-276 liner.

The liner, with its pressed cap, is contained within a fuel capsule (5.5" x 3.735" 00). The capsule lid is threaded for strength and welded (minimum weld penetration of 0.055" is specified) to give a positive seal. The wall thickness of the capsule is a minimum of 0.3475 inch. The fuel capsule is constructed of Hastelloy C-276 (or Uniloy HC). The capsule is inserted into the tungsten biological shield (8.367" x 6.467" 00), and the shield plug is bolted into place using three steel bolts, equally spaced on a 5.093-inch bolt circle.

I The tungsten shield is held in a horizontal position within the gener.ator's l

aluminum housing by the sized Min-K-1301 thermal insulation. Min-K and load bearing Glasrock are used to support the shield base. A retaining ring is used to preload the Min-K and to dampen any vibrational loads.

8204.290 9 Q,

a Paga 2'- Certificate No. 9085 - Revision No. 2 - Docket No. 71-9085 (2) Description (continued)

The finned 6061-T6 aluminum housing forms the outer protective shell

~ f the generator. During shipment, the detachable fin extensions will o

be bolted to the fins. This increases the fin diameter from 22 inches to 26 inches, holding the generator securely in the shipping cask body (5.68" min. wall thickness, ASTM A-181 grade 2 forgad steel).

The interface between the overlapping fin surfaces is coated with a heat transfer compound (DOW Corning 340). The total system weight is approximately 7,400 pounds.

(3) Drawings The principal features of the package are shown in the drawings contained in the Teledyne Energy Systems application, dated March 3, 1977.

(b)

Contents (1) Type and form of material (i) Strontium 90 titanate doubly encapsulated in a stainless steel liner and Haste 11oy or Uniloy HC capsule which meet the require-ments of special form as defined in 10 CFR 571.4(o).

(ii)

Strontium fluoride (90SrF ) doubly encapsulated in a Haste 11oy or 2

Uniloy fuel capsule, with a Haste 11oy C-276 liner which meets the requirements of special fonn as defined in 10 CFR 571.4(o).

(2) Maximum quantity of material per package 55,000 curies.

6.

The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b).

7.

Expiration date:

April 30,1987.

l REFERENCE Teledyne Energy Systems application dated March 3,1977, as amended by Teledyne Energy Systems' letter dated March 17, 1978.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety APR 131931 Date:

E' U.S Nuclear Regulatory Commission Transportation Certification Branch Approval Record Model No.:

SENTINR 8S Docket No. 71-9085 By application dated February 3, 1982, Teledyne Energy Systems requested renewal of Certificate of Compliance No. 9085.

No changes have been requested or made to the package since approval of latest supplement dated March 17, 1978.

The staff concludes that the statements of the original application, as supplemented, satisfies the requirement for renewal of the Certificate of Compliance.

y -)l Charles E. MacDonald, ChieT Transportation Certification Branch Division of Fuel Cycle and Material Safety, NMSS 0

Date:

l

.sm-