ENVIR0tNENTAL EMERGENCY KIT AND EMERGENCY OPERATIONS FACILITY RADICLOGICAL EQUIPfENT EPIP 550-2 TABLE OF CONTENTS SECTION TITLE PAGE DATE REVISION Table of Contents 1

MAR 2 51982 3

3 A.

Purpose 2

MAR 251982 8.

References C.

Prerequisites D.

Precautions E.

Limitations & Actions F.

Procedure 3

MAR 2 51982 3

G.

Checklist H.

Technical Specification / References Attachment A 4

12-15-81 2

5 MAR 2 51982 1

6 MAR 2 51352 1

Attachment C 7

MAR 251982 1

EOF (Westirghouse Nuclear Training Center) (Map) 8

?.'A't 2 5 1322 0

6

- 3",9,u?7$$? 0003'L C.

OM;;;--

w.

M l

This precedure contains 8 pages.

APPROVED E M DAR MbN 1

8 2 0 <12 70 / $ /

0007A i

EPIP 550-2 R3v. 3 MAR 251982 ENVIROMENTAL EMERGETY KIT AND EERGENCY OPERATIONS FACILITY RADIOLOGICAL EQJIFtENT A.

PURPOSE The purpose of this procedure is to outline the equipment to be maintained in the environmental emergency kits and in the Emergency Operations Facility (EOF). The procedure also addresses special tests and surveillance requirements.

8.

REFERENCES 1.

Generating Station Emergency Plan (GSEP) 2.

EPIP 550-1 "On-Site Non-Radiolcgical Emergency Respense Equipment" 3.

EPIP 550-3 " Radiological Supplies for Medical Emergencies" 4.

EPIP 550-4 "On-Site Radiological Emergency Response Equipment" 5.

EPIP 550-5 "TSC and OSC Radiolcgical Supplies" C.

PREREQUISITES None D.

PRECAUTIONS None E.

LIMITATIONS & ACTIONS 1.

There are 2 environmental emergency kits, located in the emergency trailer.

2.

No equipment in the environmental kits nor the EOF should be needed for on-site radiological purposes. Such equipment is referenced in EPIP 550-4 and EPIP 550-5.

3.

The Rad Chem Supervisor or his designee will be responsible for documentation and control of these supplies.

e 004eiE -

2 0007A

EPIP 550-2 R;v. 3 MAR 2 51982 l

F.

FROCEDURE 1.

Once per month, check the oil and gas of the emergency generators (located near the kits in the emergency trailer). Start and run the generators for thirty (30) minutes. Note any abnormalities en Attachment A 2.

Once per mrnth, perform a battery check of the radiation detectors and verify they have been calibrated within the quarter.

Inspect the probes for damage. Fill out the apprcpriate information on Attachment A.

3.

Verify the self readers have been calibrated per requirements of RP 1250-3. Test the dosimeter charger. Fill cut the apprcpriate information in Attachment A.

4.

Once per quarter, perform an inventory of the supplies as cutlined in Attachments 8 and C.

The items in Attachment C are located in the EDF GSEP cabinet or in a footlocker in the storage room (see attached map). The key to the storage rcom may be obtained from the receptionist or guard.

5.

Return appropriate forms to the rad / chem foreman. The rad / chem foreman shall correct any defects indicated in Attachment A and shall replace any missing items indicated in Attachment B and C as soon as possible.

~

~

G.

CHECXLIST Attachment A, " Equipment Tests", " Environmental Emergency Kits" Attachment C, " EOF Radiological Supplies" H.

TECHNICAL SPECIFICATION REFERENCES None 0046E 3

0007A

e EPIP 550-2 Rsv. 1 MAR 2 5 1982 ATTACH!{NT 8 ENVIRONENTAL EMERGEtCY KIT EQUIPMENT DESCRIPTION Quantity Quantity COMENTS I

Recuired Present j

Ion Chamber (range to 50 R/h) 1 Count Rate Meter 1

G-M Probe 1

Alpha Probe 1

Self Reading 00simeter (2001R) 3 Self Reading Dosimeter (lR) 10 Self Reading 00simeter (lm) 4 i

Dosimeter Charger w/ batteries 1

Stop Watch 1

l Ccmoass 1

Pocket Knife 1

Check Source (Cs-137, 8 uCi) 1 Film Badges (Beta, Gamma, X-Ray) 12 State of Illinois Gate Key 1

Fuses for Air Samo (61/4 & 15 Amo) 5 ea Flashlights w/ batteries 3

Masking Tape (2" ro'_'.)

1 Orange Fluorescent Paint Spray Cans 2

SH-4 Samole Holder for HP-210 Probe 1

Scissors 1

Duct Tape (Roll) 1 Smears (Box) 1 Silver Zeolite Air Sarrole Ctetridges 20 Particulate filters (47mm) 50 Rad Barrier Ribbon (50 yd Roll) 1 Plastic Surgecn's Gloves (pair) 15 l

l

++

l Radiation Signs Terri Towels (75/cak) 2 l

Liter of Detergent h

1 I

l Filter Medium Holders (clastic) 25 l

l Samole Labels 100 l

l

    • - Varicus RCT Initials:

Date:

0046E 5

OC07A

EPIP 550-2 Rev. 1 ATTACHENT 8 NAR 2 51982 (Continued)

ENVIRONENTAL EMERGENCY KIT EQUIPMENT DESCRIPTION Quantity Quantity COMENTS Recuired Present Tweezers 2

Plastic Bags (Medium Size)

Soil, Vegetation & Water Sample Kit 10 (3 Bottle Set for Collecting Samo)

Shovel 1

9 Volt Batteries (Scare) 5 "D" Size Batteries (Scare) 12 "AA" Size Batteries 2

Full Face Mask 3

Particulate /Charecal Combo Filters 3 pr Spiral Note Book -

1 Pens (Black, Felt Tio) 2 Permanent Marker (Black) 2 EG Procedures 1

Radeco Air Samo w/47mm part/ cart head 2

First Aid Kit 1

Highway Flares 12 Tool Kit (Pry Bar, Screw Drivers, 1

Large Hammers, Pliers)

Map (M Prints) 2 Mao (State Drawing) 1 Radio Belt 1

Stake (4') For Supporting Air Sampler 1

Off The Ground (near kit)

Anti C Clothing Set (Coveralls, Hood 3

Rubbers, Booties, Gloves & Liners)

Rain Suit (Yellow Plastic) 3 6' Ladder (lecated near kit) 1 Gas Generator (located near kit) 2 Potassium Iodide Tablets 10 l

++ - Various i

RCT Initials Date 004E 6

0007A

EPIP 550-2 R:;v. 1 MAR 251982 ATTACH 4ENT C EMERGENCY OPERATIONS FACILITY, RADIOLOGICAL SUPPLIES DESCRIPTION Quantity Quantity C0t+ENTS Recuired Present Anti C Clothing Set, varicus sizes

  • 30 Surceans' Caps 30 Cotton Glove Liners (Spares) 15 or Rubber Gloves (Spares) 15 or Surgeon's Gloves 30 or Half Masks 15 Full Masks 15 Particulate / Charcoal Cembo Filters 30 or Potassium Iodide Tablets 250 Film Badces (< 4 mo. old) w/ holders 30 0-500 trR self readers 15 0-1000 mR self readers 15 Dosimeter Charger 1

Eberline RM-16 1

HP 210 or 260 Probe w/ samole holder 1

Dose Rate Instrument 1

Air Sanoler w/ supplies 1

00CM 1

Environmental EPIP's 1

Timekeepina Sheets 5

Survey Sheets 10 1

Anti-C Clothing Sets Include: Coveralls

+

Booties Rubbers Glove Liners Rubber Gloves RCT Initials Date 0046E 7

0007A

EOF (Wactinghouse EPIP 550-2 Nucle r Trcining Center)

R;v. O MAR 2 5 Il82 Storage roort Simulator Simulator Double doors HALLWAY f

~

9 telephones station support personnel & press information phone h hookup Southk North Entrance Entrance ri,,,,,,, n u,n

,/,,,/,//

MOTOROLA Soda RADIO AM machines tu o_

HOOKUP m<

or

~

TalcphorLe ctorcge

~

ENVIRON. GROUP RECOVERY @

r==

"^p ^8 hone MANAGER IBM Motorola

@ CCC, EOF, l

printer radio TSC phone

"'elephone

@ NRC red

-l I

nterfaca GSEP phone E

CABINET @

a i

l

-O

@ Locations of EOF IBM term.

phone hookup radiological supplies hTelephonehookup E 120 volt outlet FINAL