ML20052A002

From kanterella
Jump to navigation Jump to search
Forwards List of Proposed Basalt Waste Isolation Project Site Suitability Issues,Review Assignments & Grouping Matrix
ML20052A002
Person / Time
Issue date: 03/19/1982
From: Wright R
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To: Bell M, Miller H
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
References
REF-WM-10 HLWR, NUDOCS 8204260417
Download: ML20052A002 (9)


Text

M -I POW-MAR 191982 fg/a,, ~N 3104/RJW/82/03/19/0 DISTRIBUTION

/J S U f4 7-SJ ldM l+ T.' $b'/

UNHT r/f RWright S r/f FDlb MEMORANDUM FOR: Michael J. Cell, Chief

/

High-Level Waste Licensing W

  1. /

Management Branch Division of Waste Management Hubert J. Miller, Chief High-level Waste Technical Management Branch Division of Waste Management G

E' N

<O FROM:

Robert J. Wright, Senior

.f,9 Technical Advisor

' ' ~,7 4

o Y g?.#

High-Level Waste Technical n

Management Branch nj r# 2 o

s%ggP~/#:

Division of Waste Management rd 3

p

,\\

SUBJECT:

BWIP SITE SUITABILITY ISSUES

'K

>\\j

' %,/

Attached is a list of proposed BWIP site suitability issues.

Proposed review assignments are noted. Also attached is a chart which portrays the key elements of review topics which guided the allocation of review issues to the five review topics.

The following notes are relevent to the issues list.

1.

A site issue is a broad question that is critical to site suitability and should be answered during site characterization.

2.

The issues have been derived from a number of sources, including (a) documents of BWIP; (b) reviews by the National Acedemy of Science, the BWIP hydrology and geology overview committees, the Office of National Waste Terminal Storage Integration; and (c) site visits by NRC staff and consultants.

3.

The statement of an issue reflects a " bare bones" treatment.

In particular, no mention is made of procedures or methods, which may be important components of some issues.

These will be discussed in issue development.

4.

Although the intent is to list first, within each topic, the DIST:

TICKET NO:

0FC :

NAME :

DATE :82/03/19 8204254n

3104/RJW/82/03/19/0

~2-MAR 191982 Michael J. Bell more important issues, no great significance can be attached to the ordering of issues.

5.

Some issues, eg. vertical permeability, are part of other, larger issues but are listed separately because of importance.

The next steps are for each issue reviewer to develop the issue and a review schedule thereforc in accordance with steps 1.2, 1.3 and 1.4 of the SCR Review Plan.

4_).

Robert J. Wright, Senior Technical Advisor High-level Technical Division of Waste Management DIST:

TICKET N0:

OFC :

. _ _ _ : _l#SIL _ _ _ _ _ _ : _ _ _ _ _ _ _ _ _ _ _ _ : - _ _ _ _ _ _ _ _ _ _ _ :: _ _ _ _ _ _ _ _ _ _ _ _

NAME :

\\l

_ _ _ _ _ : _Edliti}g h t :.dm : _ _ _ _ _. _ _ _ _ _ : _ _ _ _ _ _ _ _ _ _ _ _ : _ _ _ _ _ _ _ _

DATE :82/03/ f

J J.2 4

. f

.y

~~

. jl p%

J[Qo #

of

.4 C

I di d

.-_h r%

t* 4 L[.. -

.j i

tIb t

.~

Si

. d

.Ak 4

[ $

b W}, A...-

. h, k'. (,

2 S

~

)i

A t EL2 m

4_

e m, 4

+

y e

w c

c P

jn y N./

~ :::

~

.y,p ;f gy a ya

% q}OI kj e

'a H1 (

7-

~

k j

-g j

f

-<d E

e

,k k B

4 f)

.]

e p93 a

N,,

1.

- ut

!!P36 9 Adb f

~ ~

A*

g l

l 2

[g c

o r N.

t

.3 L

3 Liu

. - _.T1

s

~

~

A 1

6-

=.

O

~g.--ee a

e.g ee-e.w-e

.w+

ee

_4

/

4 UNITED STATES

[% )g/4P[ g NUCLEAR REGULATORY COMMISSION j

W ASHINGTON, D. C. 20555 5.l h MAR 19 1993 I

BWIP SITE SUITABILITY ISSUES A Transport A-1 What is the accessible environment?

Quinn I

A-2 What hydrostratigraphic units are used for modeling and testing?

What is the basis for identification?

Johnson A-3 What is the areal distribution of values for the hydrogeologic parameters needed to calculate groundwater flow paths and travel times?

Verma l

A-4 What are the effects on groundwater flow of structural, stratigraphic and lithologic heterogeneities in the basalt section, with emphasis on the Umtanum?

Johnson A-5 What are the groundwater recharge and discharge locations, mechanisms and amounts for the Pasco Basin flow systems?

Quinn A-6 What is the solubility of radionuclide-bearing compounds and phase stabilities in the groundwater system?

Brooks A-7 What are the retardation properties of the mineral phases which line fractures?

Brooks A-8 What is the age and chemistry of groundwater in the host rock?

Corrado A-9 What are the groundwater flow paths, travel times and radionuclide releases under existing conditions?

Quinn A-10 What are the expected effects on groundwater flow paths, groundwater travel time and radionuclide transport of future, natural changes?

Quinn A-11 What are the expected effects on groundwater flow paths,

. groundwater travel times and radionuclide releases of repository-induced changes?

Quinn A-12 What are the expected effects on groundwater flow paths, groundwater times and radionuclides releases of human-induced changes?

Quinn

d, 3-L B Stability B-1 What are the probabilities and nature of natural changes that would adversely effect repository performance?

Pendleton l

B-2 What are the probabilities and nature of human-induced changes l

that would adversely affect repository performance?

Verma B-3 What are the probabilities and nature of repository-induced changes that would adversely affect repository performance?

Rhoderick B-4 What is the seismic hazard to surface and subsurface facilities?

Prestholt 4

B-5 How does the value of mineral resources at the RRL compare with the values in other areas of similar size within the geologic setting?

Wright B-6 What effects on repository performance can be expected from the Pleistocene faults on Gable Mountain?

Pendel ton B-7 What are the effects of future groundwater use on radionuclide isolation?

Verma i

I h

l i

s f

i a

t e

,--we-,

r,

-~,,----,m.-

,n-.-

y y

' ' s:.

f 4-1 C, Rock mechanics, repository design C-1 Are the repository design criteria and the functional description complete and accurate with respect to the performance objective of isolating waste?

Pittiglio C-2 Is the conceptual design consistent with the design criteria and the functional description and appropriate to satisfaction of the performance objective?

Chase C-3 How does the conceptual design accommodate thermal and mechanical effects due to waste emplacement?

Seamans i

C-4 How does the conceptual design accommodate stresses in the i

4 repository host rock?

Hartung C-5 How is long term performance, in isolation of radionuclides, affected by construction of the Exploratory Shaft?

Rhoderick i

1 i

.a.

i w er.

-w..

=

e

s'.

! D Engineered Darriers, waste form D-1 How is the performance of each barrier component expected to be affected by the following parameters:

1 (a) Hydrostatic head differentials and hydraulic conductivities between locations in the near field.

4 (b) Rate of deformation of repository surfaces and resultant loading of engineered system components.

(c) Electro-chemical potentials in the repository host rock.

3

.(d) Electrical conductivities of the ground water and the saturated repository host rock.

'(e) Thermo-dynamic parameters, including heat conductivity, heat capacity and heat transfer coefficients.

(f) Gas transfer.

Cook

-D-2 What is the effect on radionuclide transport of changes in 1-chemistry of the engineered barriers?

Brooks 1

l

~

l l

+

i b

$9 a

.,, +.-

d. '. r *. E Institutional and environmental E-1 What was the decision making process for selection of the candidate area and site?

Uleck E-2 What technical factors were considered in selection of the condidate area and site?

Coplan E-3 What institutional factors were considered in selection of the candidate area and site?

Uleck E-4 What environmental factors were considered in selection of the candidate area and site?

Pflum E-5 What other sites are under consideration for characterization?

Coplan

-