Text
Fod NRC 618 U.S. NUCLE AR REGULATORY CORN /ISSION (F
CERTIFICATE OF COMPLI ANCE
's H -
For Radioactive Marsrids Packaget 10 Pages No. 1.(e) Total No. Pages USA /59le Idenfsfi}ation No.
1.(d) 1 3
1.tc) Packa 1.tal Certsfecate Number 1.(b) Revis;on No.
6/C F
5916 3
- 2. PRE AMBLE 2.(a)
This certificate is issued to satisfy Sections 173.393a.173.394,173.395, and 173.396 of the Department of Transportation Hazardous Materials Regulations (49 CFR 170189 and 14 CFR 103) and Sections 146-19-10a and 146--19-100 of the Department of Transportation Dangerous Cargoes Regulations (46 CFR 146-149), as amended.
2.(b)
The packaging and contents described in item 5 below, meets the safety standards set forth in Subpart C of Title 10. Codt of Federsl Regulations, Part 71," Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions."
2.fc)
This certificate does not relieve the consignor from comphance with any requirement of the regulations of the U.S. Department of Transportation or other opphcable regulatory agencies, including the government of any country through or into which the package will be transported.
- 3. This certificate is issued on the basis of a safety analysis report of the package design or application-3.f a) Prepared by (Name ar.J address):
3.(b)
Title arvi identification of report or application:
Monsanto Research Corporation Monsanto Research Corporation application P.O. Box 8, Station B dated March 1, 1982.
Dayton, OH 45407 3.(c)
Docket No. 71-5916 CONDITIONS 4.
This certificate is condit.onal upon the fulfilling of the requ;rements of Subpart D of 10 CFR 71, as applicable, and the conditions specified in item 5 below.
L Oescription of Packaging and Authorized Contents. Modet Numoer. F ssile Class. Other Conditions, and
References:
i (a)
Packaging (1) Model i;o.:
2501 (2)
Description The packaging consists of an interchangeable shielded center section, common top and bottom end sections, and up to two extension sections.
Shielding is provided in the center section by successive layers of iron, lead, and Benelex-70.
Balsa impact limiters are included in the top and bottom section.
Each steel section is bolted to the adjacent section and bolted to a steel I-beam skid-cradle assembly. The cross The section geometry is basically octagonal, 48" across the flats.
length ranges from approximately 12 to 16 feet with a maximum gross weight of 17,450 lbs.
(3) Drawings The packaging is constructed in accordance with the following Monsanto Research Corporation Drawing Nos.:
E 2501 - AA00, Rev. 2 0 2501 - AG00, Rev. 2 E 2501 - AA01, Rev. 2 0 2501 - AH00, Rev. 2 E 2501 - AA02, Rev. 3 D 2501 - AIOO, Rev. 3 E 2501 - AA03, Rev. 2 8205170 # \\
Page 2 - Certificate No. 5916 - Revision No. 3 - Docket No. 71-5916 (b)
Contents (1) Type and form cf material Po-Be, Am-Be, Pu-238-Be, and Cf-252 neutron sources. ' Sources must meet the requirements of special form as defined in 10 CFR 571.4(o).
(2) Maximum quantity of material per package 1,509 curies of PoBe, or Am-Be, or Pu-238-Be* or 8.25 curies of CF-252.
(Heat load generated by the contents must not exceed 60 watts of decay heat.)
- Plutonium in excess of twenty (20) curies per package must be in the form of metal or metal alloy; or contained within double encapsulated stainless steel source capsules. Both capsules must be leak tested having a minimum sensitivity of 1x10 ge for a test independently, and must show no leaka 3
(airat25Cand1atmleakingto1x10gtm-cm/sec atm).
(c)
Fissile Class I
For packages containing Pu-238.
The contents must be secured in the shielded position of the packaging by the 6.
source assembly, and locking device. The source assembly must be of sufficient length and diameter to provide positive positioning of the source in the shielded position.
The nameplates must be fabricated of materials capable of resisting the fire 7.
test of 10 CFR Part 71 and maintain their legibility.
The package authorized by this certificate is hereby approved for use under the 8.
general license provisions of 10 CFR 571.12(b).
9.
Expiration date: April 30,1987.
1 i
y
p Page 3 - Certificate No. 5916 - Revision No. 3 - Docket No. 71-5 16 1
REFERENCE Monsanto Research Corporation application dated March 1, 1982.
FOR THE U.S. NUCLEAR REGULATORY COPetISSION f
k
~d/
Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety
- r'; a E02 I
l
. _ _.., _.. ~. _ _,, - _ _ _..
U.S. Nuclear Regulatory Commission Transportation Certification Branch Approval Record Model No. 2501 Docket No. 71-5916 By application dated March 1, 1982, Monsanto Research Corporation requested renewal of Certificate of Compliance No. 5916.
It was required that all supplemental information referenced by the Certificate of Compliance be incorporated into a consolidated application.
The consolidated safety analysis report contains the original application as amended by the supplements referenced by the Certificate of Canpliance.
The applicant has also updated the sections on dose rate determinations to include dose measurements on all shipments through January 1982. As a result of this updating, the applicant concluded that the maximum quantity of ' aterial per package needs to be reduced from 1,848 curies m
of Po-Be, or Am-Be, or Pu-238-Be to 1,509 curies and the maximum quantity of Cf-252 from 13.2 curies to 8.25 curies. The staff has reviewed the data on dose rate determinations and dose measurements and agrees with the applicants proposed reductions.
No other changes have been re. quested or made to the package since approval of latest supplement dated November 8,1978.
The staff concludes that the consolidated safety analysis report satisfies the requirements for renewal of the Certificate of Compliance.
M Charles E. MacDonald, Chief Transportation Certification Branch Division of fuel Cycle and Material Safety, NMSS A?F. 2 " 1992 Date:
G
+
_