ML20051D486

From kanterella
Jump to navigation Jump to search
Interim Deficiency Rept Re 3/4-inch Carbon Steel Pipe Cracking,Initially Reported on 820401.Investigation Continuing to Determine Where Similar Matl Is Located. Next Rept Expected by 820827
ML20051D486
Person / Time
Site: Fermi 
Issue date: 04/30/1982
From: Wells D
DETROIT EDISON CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
10CFR-050.55E, 10CFR-50.55E, EF2-58065, NUDOCS 8205140562
Download: ML20051D486 (1)


Text

-

CD e

oy Donald A. Wells var.v;m an n k, r.e.w g

Detroit

~""

nec kh iSOn 'm*00 Second Avenue"n ~ew "*=

g.

MAYI 3 798A 21 20 2

tt t.au ga;.

'Emmar g78 April 30,1982 9

M EF2-58065 Cu

/

ru Mr. Jarres G. Keppler, Regional Administrator Region III U.S. Nuclear Regulatory Ccmnission 799 Roosevelt Road Glen Ellyn, Illinois 60137

Subject:

Interim Report of 10CFR50.55(e) Item on 3/4" Carbon Steel Pipe Cracking (#64)

Dear Mr. Keppler:

On April 1,1982, Project Quality Assurance's Mr. E.L. Thompson, Acting Supervisor-Construction Quality Assurance, telephoned Mr. J. Konklin of NRC-Region III, to report on a problem with 3/4" Carbon Steel Pipe Crack-ing at the Fermi 2 site.

This item deals with a length of 3/4" Carbon Steel Pipe, that cracked during a flushing operation. The vendor was contacted even though the Certified Mill Test Report shows an acceptable hydrostatic test pressure of 2,500 psi.

The vendor responded that the flaw appeared to be caused by a defective extru-sion mandrul. Investigation is continuing to determine where similar material is located. Reportability will be determined by the safety implications of the installed pipe.

Another report on this item, either interim or final, is scheduled to be sent to you on or before August 27, 1982. If you have questions concerning this matter, please contact Mr. H.A. Walker, Supervisor-Construction Quality Assurance.

Very truly yours 1

/

DAW / HAW /cp cc:

Mr. Richard DeYoung, Director Office of Inspection and Enforcement Division of Reactor Inspection Programs U.S. Nuclear Regulatory Comrnission Washington, D.C. 20555 Mr. Bruce Little, Resident Insp2ctor U.S. Nuclear Regulatory Connission 6450 North Dixie Highway Newport, Michigan 48166 5140562 820430 10 m ADOCK 0500034j g

PDR

$s[p TC j