I YANKEE ATOMIC NUCLEAR POWER STATION MONTHLY STATISTICAL REPORT 81-10 FOR THE MONTH OF OCTOBER, 1981 f
f i
8203290163 811110 PDR ADOCK 05000029 R
PDR m -+<
r.,w- - -
ym p
.e----asm-g
'e
t OPERATING DATA REPORT DOCKET NO.
50-29 DATE 811110 COMPLETED 8Y A E. Dnvle TELEPHONE 617-877 R100 X2390 OPE' RATING STATifs Notes Yankee Rove
- 1. Unit Name:
October. 19R1
- 2. Reporting Period:
Power level restricted by 600
- 3. Licensed Thermal Power (MWt):
installation of baffle 185
- 4. Nameplate Rating (Gross MWe):
P ates in turbine, l
175
- 5. Design Electrical Rating (Net MWe):
180
- Time Zon Change 10/31/81.
- 6. Maximum Dependable Capacity (Gross MWe):
175
- 7. Maximum Dependable Capacity (Net Slwe):
- 8. If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report.Give Reasons:
150 MWe
' 9. Power Lese!To Which Restricted.If Any (Net MWe):
See Norom
- 10. Reasons For Restrictions.If Any:
This Month Yr to.Date Cumulative
- 745.00 7.296.00
- 11. Hours in Reporting Period 745.00 5.132,87 145.467.15
- 12. Number Of Hours Reactor Was Critical 0.00 0.00 0.00 I
- 13. Reactor Reserse Shutdown Hours 745.00 5.054.77 141.016.50
- 14. Hours Generator On.Line 0.00 0.00 0.00
- 15. Unit Reserve Shutdown Hours
- 16. Gross Therma! Energy Generated (MWH)
AAA_A9n nn 2.756.584.71 75.630.365.52 114.829.00 725.031.50 23.110.172.00
- 17. Gross Electrical Enesgy Generated (MWH) 106.855.41 671.297.49 21.629.407.18
- 18. Net Electrical Energy Generated (MWH) 100.00 69.28 76.72__
- 19. Unit Service Factor 10n.0n 69.?R 76.72
- 20. Unit Availability Factor 81,96 52.58 69.32
- 21. Unit Capacity Factor (Using MDC Net) 81.96 52.58 69.32
- 22. Unit Capacity Factor (Using DER Net) 0.00 1.88 5.26
- 23. Uni Forced Outage Rate
- 24. Shutdowns Scheduled Over Next 6 Months (Type.Date.ind Duration of Eacht:
- 25. If Shut Down At End Of Report Period. Estimated Date of Startup:
Forecast Achieved
- 26. Units in Test Status (Prior to Commercial Operation):
INITIA L CRITICALITY INITIAL ELECTRICITY COstMERCIAL OPERATION t /77) 9
0 AVERAGE DAILY UNIT POWER LEVEL DOCKETNO. 50-29 UNIT Yankee Rowe 811110 DATE COMPLETED BY A. E. Doyle 617-872-8100 X2390 TELEPHONE MONTH OCTOBER, 1981 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe Net)
(MWe-Net) 142.4 143.1 37 g
2 143.2 gg 141.9 3
143 4 19 142 7 4
143.9 20 141 R 5
143 4 21 143.7 143.1 22 143.6 7
143.2 23 142.3
'142.3 8
144 3 24 134.9 25 144.6 9
to 144.3 26 144.4 I44 1 27 145.2 11 145.7 143.7 28 12 i
143.2 29 145.7 13 142,7 30 145.9 34 15 142.6 31 146 1 16 142 3 INSTRUCTIONS On this format. list the average daily unit power level in.\\lWe Net for each day in the reporting month. Compute to the nearest whole megawatt.
(9/77)
UNIT 9tUTDOWNS AND POWER REDUCTIONS DOCKET NO.
50-29 UNIT N A' t E Yankee Rowe DATE 811110 REPORT MONTil OCTOBER, 1981 COMPLETED 11Y A.
E.
Doyle TELEPilONE 617-872-8100 x2390 We E
E
.! E 3
}.E 5 Licensec E *,
ja.
Cause & Corrective Nii.
Date 1
3 Ej g5 Event u
n?
Action in
- v?
g3 E 5
j;5g Repott
- v p,,,,.L: kccierrence 6
NONE N/A N/A N/A N/A N/A N/A N/A N/A N/A a
I 1
3 3
4 F: Fosted Heason:
Method:
Enliibit G Instructituis S: Sclieduled A Equipment Failure (Emplain) 1-Manual for Pscras sinn of Data ll. Maintenance of Test 7-Manual Scram.
Entry Slic. is for Licensee I
C Refueling 3 Automatic Scram.
Event IterinI (Llin) Fde INURf.G-D Hegulaimy Resisiction 4-Other (Emplain) 0161) li Opciator Tsaining& License Examination F Ailministiative 5
G Opesatismal lune (limplain)
Eminhis I Same Sousee
(*8/17)
Il Othes Ilimplain)
e DOCKET NO.
50-29 UNIT Yankee Rowe DATE 811110 COMPLE~iED BY A. E. Doyle TELEPHONE 617-872-8100 X2390 REPORT MONTH OCTOBER, 1981 Stre!ARY OF OPERATING EXPERIENCES 10/9 At 0500 hours0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> a load reduction commenced, to perform turbine throttle and control valve exercise. At 0630 hoars completed the control valve exercise. At 0715 hours0.00828 days <br />0.199 hours <br />0.00118 weeks <br />2.720575e-4 months <br /> the No. 2 Heater Drain Ptmp was removed from service to allow repacking. At 0815 throttle valve exercise began. At 0915 hours0.0106 days <br />0.254 hours <br />0.00151 weeks <br />3.481575e-4 months <br /> the throttle valve exercise was completed. At 0950 hours0.011 days <br />0.264 hours <br />0.00157 weeks <br />3.61475e-4 months <br /> No. 2 Heater Drain Pump repacking and run in were completed. At 1000 hours0.0116 days <br />0.278 hours <br />0.00165 weeks <br />3.805e-4 months <br /> load increasing began. At 1400 hours0.0162 days <br />0.389 hours <br />0.00231 weeks <br />5.327e-4 months <br /> the plant was at a full load condition.
t
-m