ML20049A408
| ML20049A408 | |
| Person / Time | |
|---|---|
| Site: | Calvert Cliffs |
| Issue date: | 01/20/1981 |
| From: | BALTIMORE GAS & ELECTRIC CO. |
| To: | Grier B NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| References | |
| RO-81-005, RO-81-5, NUDOCS 8101270660 | |
| Download: ML20049A408 (2) | |
Text
,
B ALTIMORE G AS AND ELECTRIC comp ANY
... 1 m S ALTIM Oe s. M A R YL AM o a1203 TM...',".,.'a..*m!",* T.'.S. ":"J........
January 20. 1481 Mr. ' oyce et, i-rier. Director d
Office of Insnection & Enforce..ent U.S. Nuclear Regulator, ro riission Recion 1 631 Park Avenue Xiao of Prussia. P4 loa %
WB.itCI: Docket 40. 50-315 LE'i 31 06 This is to confim our veriaal notification to your "r. bleh arcsitzei of an inadvertant noenina of cows.r onerated relict volve RC AC4-EHY.
This rerort is beinn r,ade in accordance witn IV inst'ection Rcenrt 317-79-23.
0 At 0647 on 1-18-81 irith the Rector Coolant Svste n (RCS) at 720 F and 230 esfa during a cooldoven for a scherfuled refueline outace, nressure indicatine controller P!C-103-1 failee' hien causine PC-404-ERY to onen.
P!C-103-1 monitors pressurizer acessure and nrovides a sianal to onen t
RC-404-ERY at 430216 nsia when the OCS is below 2MDF. Wnen the valve onened the enerator received *PORY/ Safety Valve Acoustic !'onitor" and i
"PORY Ener ized" 41 ann. /tf ter acknowledcino t'ic 41anns. the entrator i
noted that 8.C-404-ERY was oren and shut newer relle' isolatioit RC-405-!iOV tenninatine the discharne.
IT-414-ERY was cren Icss than ene minute and RCS pressure decreased a'nroxinately six rsi.
The redundant over nressure oretection syster rcNinet* nrerabic durine tne event, i
A com1ete descrintion of the cause and corrective action will be contained in the follow-un renert.
I
/
l M #filifTuTirTn'Tenlent -l a
c3 Calvert Cliffs :locicar Pruer plant g
1.BR:S"D:e r f[
cc:
L.s. Hussell J
d4gg OIS81 A cI2 p.,
Director. Office of '*arrement Information c1u,,,%"'%**%[-
and Procran Centrol M
Messrs:
J.A. Tiernan 0
R.H. Douc1as s
% ' 'ca R.E. Arcni tzc1 L
sl va 9
((8 8101270 W O ~
~~
S
NRC FORM 366 U. S. NUCLE A?. CEGULATCY COMMISSION mni,
LICENSEE EVENT REPORT CONTROL BLOCK: l l
l l
l l lh (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION:
1 6
Rl l
l l
l l
l@l l
l l
l l
l l
l l
l l@l l
l l
l l@l l
l@
7 8 1 LICENSEE CODE 14 15 LICENSE NuM8ER 25 26 LICENSE TYPE JO
$7 CAT 68 CON T Z%U i l@lolfidlo ldl51l IT G10 Il li ISIffil l@l ol i 11 tolSI / l@
lolti 7
6 60 61 DOCK ET NUMBER 66 63 EVENT DATE 74 7$
REPORT DATE 50 EVENT CESCRIPTION AND PROBABLE CUNSEQUENCES h l o 121 l l
1 o 6 31 I I
10141 1 1
10151 l I
iTITl i I
10171 I I
l 10181I 80 7
8 s CE CODE SL8C DE COMPONENT CODE SUSCOCE S
E io191 I
I l@ L_J@ l l@ l I
I I
I I
l@ l l@ L_l @
7 8
9 10 11 IJ 13 18 19 20 SEQUENTIAL OCCUR RE NCE REPORT REVISION LER EVENT YEAR REPORT NO CODE TYPE N O.
@ yup,RO 19111 L-j 1510151 Ld i
I I
I I
L-J l
I g
as
'3 24 26 27 28 29 30 31 32
_ 21 22 J
TA N AC O P NT M T HOURS S8 i E POR 8.
SUPPL E MANUPAC RER I
l@l l@
L_1@
I l@
l i
I I
I L_J@
l l@
l l@
l i
I I
l@
33 J4 JS 36 31 40 41 42 43 44 47 CAUSE DESCRIPTION AND CCRRECTIVE ACTIONS h I
mI I
LLLU l l
il ia I
11 131 I l
Wl 80 7
8 9 DISCOVERY DESCRIPTION h 6 POWER OTHER STATUS Dis O RY
$A LLL5J L_J@ l I
i 181 I
I I@l I
8 4!T,v,Tv CO TENT AuOuNT OP ACTiviTv @ I LOCATiONcPRELEASE@
Rett ASEo@OP aELE ASEL_l@l I
I li Is l I l
PERSONat E POSSES DESCRIPTION TYPE @l NuveER li l 71 I I
I l@l l
2 PERSO~~Et mu'R1ES oESCRiPTIO~@
NuM.ER li ta l I I
I l@l I
80 7
8 9 11 12
'4 55 "fSC'"'A'ON '^ " @
E liial I l@l I
30 7
4 3 to 8
DESCRIPTION IS';UEf@l t_
i illitiliti!!I,:
12ioi 68 69
- 80. C 1
a 3 to NAME OF PAEPARER PHONE: