ML20049A392

From kanterella
Jump to navigation Jump to search
Response to ASLB 801120 Order,Providing Nexus Between BWR-VI Jet Pumps & Earlier Bwrs,In Support of Intervenor 801015 Contention 50.Certificate of Svc Encl
ML20049A392
Person / Time
Site: Allens Creek File:Houston Lighting and Power Company icon.png
Issue date: 01/06/1981
From: Doherty J
AFFILIATION NOT ASSIGNED
To:
Atomic Safety and Licensing Board Panel
References
NUDOCS 8101160184
Download: ML20049A392 (3)


Text

.

January 6, 1931 U:.I TEu 3 7.i ?ZG JF A:..ERIC A

!.UCLEArt REOULA N!?Y C0.0 /ICSIvN h' /O R" 7"-

ATO..IC 3,iFETY nau LICE::SI..G SOARD In the...atter of

)

)

'JUL.; 0C:. LIC"?:. G 6: P0;TdR CO..+ A'.;Y

)

Docket No. 50-464

)

12 (Allenn Creek :uclear Generating

)

Ste'. ion, Unit 1)

)

g,"..,c

\\

d4gle'00 0

IU7RVSt!OR DOMER ?Y'S RESFC:;3E TO BOARD 3

07 DER CF NOV. 20, 1990, '3ITH LSIECO TO HIS ;

m o,,g o/g

.A8 CC!~E ? ION '/90 REGARDI?.G BdR JE2 PU.MPS E

n # oe&

g 4

On Cc'.

15, this Intervenor fi]cd a late conte 4

4

\\

and nunnor+ine n*emant with regnrd to tbc coolant cn circulstion.i a ' numps being subject tPrough normal use

'o disacse-bly nni/or knzardonc dinn11 cement due to degra-dn tion duri.'

nortP1 oper1?lon.

In the above Ordar the Bo'.rd conditionally admitted the Contention pending the Me'.13*:n:c of a proper nexus between the BJR-VI jet pumps of ACNGS and those of several earlier B'#Rs mentioned in IE Sulletin No. 30-07

'his Intervenor filed a single set of interrogn'ories to the Staff (Dec. 2, 1090), replies for which wera received Jan. 2, 1931.

'his resnonne is intended tn provi de the mic9ing nexun.

  • ke Conten' ion nightn a problem where matal co ronentg.___..

'o hold the ja' rvmp in nince.

In the PSAR of AC::GS,

'ra ey.ct metallic co nosition.vns unspecified.

However in M 'ha s

- 'he 6bly 3.'R-6 npproaching an oneratinc license, Grnnd Gulf.

'Pe hol.d-down beam in of +he name etal(Inconel X-750) as o3

[h'ne D*n ia- "-i+

7' plant.

In IE Eulletin 160. 30-07, that 5

-k,rn-in plant ir cited :n h, vin 3 a hold-down beam failure.

/ Q

~

resulting in jat pump failure.

In i+s response to Inter-regatery 54, Staff in "NRC Staff's Response to Intervenor Dokerty's Firs' 3et of Snecial Interrocatories on His Conten-tion "50"Ipaae E) has identified Inconel x-750 as the material used in hold-down beam assembly in that niant.

"ence, the hold-down beam assembly of a GE Bt/R-6 is of the na.e material composition as a plant which experienced cracking after eight yenrs of service.

Here is a metal-lurgical nexus.

ext, Staff points out in the abcVe response that GE has recornized a problem exists, to wit, its issuance of nronriatary report MEDC 24,256 Clasa-III.

Evidently, Staff krs not raviewed this report, so that it is unknown if any of the Inconel X-750 assemblies of any design will be

altered, Furtker, MEDC 2E,256 Class-III nnd Service Information Letter (SIL) No. llo (see Staff Resnonse, nage 2) were both nromulented by recent(1930) problems.

Hence, there is no raason to believe that nny changes were made to ACNGS from those of Drenden Unit $3, cecause of cfforts to prevent hold-down beam cracking.

Additional evidence for this state-ment may be found in Staff's responce to Interrogatory #6 and ',he absence of any alteration in choice of materials between the designs of Grand Gulf and Drenden Unit 71, which commenced oneretion October, 1471.

The Dranden event appears

'o have baen unanticiented.

n 7

.;..=.,-.

....a e,

c.,,,.,*

    • 3 5, n.

.-* * ;.,3

.. y.., e.

,.....s.c..

.s

, :.,.1 i,

-.t 1g.....,.>,).. :..

.a..*.y,3,...

.,e

.,.e..

n,,, :.,....

6 s.

..., a. ; + ; n,.

f, q, :

., 4 -

3,, c... :.

4

(, _,,,.. i n., ;.- -

',.:cennec*

f' rom ?.! e ir.ct :. ;

m. > ' t. r :i' r:i s

t o + >.e hold-dor-bean problem.

thi:. 1

^n, it r at n ec r -we n r..r.o v o ri-1, n i '" ou d-

. i:: 1 m ing

^'

A r ~ ~.3

,,.1,11 we o (eviisntly) tow rd T.itic-ticn.

3ut at lenct nr.'i'

'Pe c"eno'an "re da' r-inad nni a-aci' icd lico.'enhie:

'hir In*.or ranor %17 ova-n 'c-tenticn ir vall-1.

v.

.,_A _ I.,, a. m1 G..,,

e........u. I.,a..

.t.

Comiec of "IliTERVENOR DOHi~t2Y'!3 R ~3PO :Od T.

3'.' ARD ORDER OF

.i:50 F MARDING 1;LV 'MB:;n 23,1980, '.!ITH R.!SN0? TO HIS 00Uf3.2I31, 3.2 JET TUMP3" were served on the parties below this ( M of January, 1981 via First Clacc U.S. Postal Service fron H.uston To::as.

Shelion '.-lolfe, 2 c. Chair, ASL3 Dr. E. Leonard Choatun, Ainin. Judge Gustave A. Linen'oer,er, A1.in. Judre Richari 1.

Black,I;RO Staff J. Grsrorv Copeland, Esn.. (Amnlicant)

Jac'- R. lie'.enan, Esc. ( Annlicant)

Jic'iard Priester, Esq. (Te:cas)

Docketiag a 3ervice Branch

' t lic J?.f et,- & ~ Licensine !.no. cal Board i

'esnectfully Subnitted, John F. Joherty a

4

\\

e 3

-4 JAN I 2198f >

s.

" Om !.N,b'"s s'm,f8f7

$5..... 8 Cee 7

g

_